Solar Panel Mechanical Load Universal Testing Machine/Pressure Testing Machine for IEC61215-2:2016 Standard

Solar panel Mechanical Load Universal testing machine/Pressure testing machine for IEC61215-2:2016 standard
Testing standard
It's conform IEC61215-2:2016 testing standard
Purpose
This test is to determine the ability of the module to withstand wind , snow , static or ice loads
The Main Technical Specifications
The machine test stand appearance dimension approx |
L 2650 × D 23200 × H ×2650 mm |
Test Positive load the maximum |
+10000Pa |
reverse load the maximum |
-6000Pa (Pressure can setting) |
Cycle times |
free setting |
Dynamic load test frequency |
7s±3s |
Dynamic load |
1000Pa,1000 cycles |
| Pressure control accurate | 5% |
|
Pneumatic and force value feedback ways |
low friction force cylinder,tensile pressure sensor(accurate 0.1N) |
|
The maximum test dimension |
2000mm×1000mm (customized) |
|
Current continuity system |
DC power, DC 120V/20A, real-time monitor module inner current continuity |
| Cylinder | 8 pcs |
| sucker | 32 pcs (one cylinder attached 4 suckers) |
| Control ways | Computer control |
| Electricity | 220V 50HZ |
Area Demand
NO |
Project |
Requirement |
1 |
Placed dimension |
2650×2320×2650mm(L×W×H)+740×740×1413mm(L×W×H) |
2 |
Weight |
Approx 800kg |
3 |
Compressor air requirement |
≥0.7Mpa, flow≥2.0m3/min |
4 |
Electricity requirement |
1phase 220V 50HZ |
5 |
Ground requirement |
Ground line connect to the ground |
6 |
Area requirement |
Flat |
7 |
Environment requirement |
25℃±2%,humidity 50%~70%, no noise , Shockproof, non-magnetic interference |
8 |
Power |
6000W |
Testing Procedure
1.Equip the module so that the electrical continuity of the internal circuit can be monitored continuously during the test
2.Mount the module on a rigid structure using the method prescribed by the manufacturer including the mounting means (clips/clamps and any kind of fastener) and underlying support rails, if t here are different possibilities each mounting method needs to be evaluated separately , for all mounting methods , mount the module in a manner where the distance between fixing points is worst case, which is typically at the maximum distance. 3.On the front surface , gradually and uniformly apply the test load, load uniformity needs to be better than ±5% across the module with respect to the test load, maintain his load for 1h
4.Apply the same procedure as in step c to check back surface of the module or as uplift load to the front surface
5.Repeat step c and d for a total of three cycles




Send Inquiry to This Supplier
You May Also Like
-
Endress+Hauser E+H Compact Conductivity Device Smartec CLD18-BGGENegotiableMOQ: 1 Piece
-
Computer Control Hydraulic Universal Testing MachineNegotiableMOQ: 1 Set
-
Universal Testing MachineNegotiableMOQ: 2500 Pieces
-
Hydraulic Plastic Flange Connections Cover Plugs SHF SeriesUS$ 0.22 - 0.28MOQ: 2500 Pieces
-
Gates 550C 550U U550 U-550 U508 U-508 Japan Unitta U-550 Belt Tension Meter New U-508 Belt Tension Meter Upgraded Version U550US$ 1 - 900MOQ: 1 Piece
-
Analytical Balanace.scale ,weichengya Laboratory SupplierUS$ 10 - 35MOQ: 10 Sets
-
Smart MD-3051 Online Density Meter With 4-20mA OutputUS$ 2,380 - 2,500MOQ: 1 Unit
-
5W-300W Sun Simulator Watt Testing 30% Off / Xenon Lamp Sun Simulator Free Sent / Sun Simulator TestingUS$ 7,500 - 10,000MOQ: 1 Set
-
New Design Measuring Meter With Best PerforanceUS$ 1,000 - 1,200MOQ: 1 Piece
-
XK-1 Rotary Switch Life TesterNegotiableMOQ: 1 Set