Home > Products > Surgical Laser > Minimal Invasive ENT Diode Laser Surgery For Stapedectomy And Stapedotomy
Minimal Invasive ENT Diode Laser Surgery For Stapedectomy And Stapedotomy
- 1000 Piece / Pieces per Month
- wuhan
- T/T Other
- 7 days
- Topmedi elderly care products TAW818LB travel folding cheap price of wheelchair for handicapped
- laser therapy
- Veterinary Orthopedic Trauma Implants 2.7 mm Reconstruction Titanium Locking Plate
- Wheelchair
- Small wheel model 7.85kg Light aircraft wheelchair
- Portable pulse type lithium battery for outdoor oxygen concentrator in high-altitude areas
Product Details
Brand Name: | dimed | Place of Origin: | China | Model Number: | Berylas 980nm |
Product Description
Minimal Invasive ENT Surgery Diode Laser For Stapedectomy And Stapedotomy
The lightweight, portable 980-nm wavelength Berylas Diode laser with a fiber optic delivery system is being used widely the field of otolaryngology.The laser transmits radiation via a flexible quartz fiber optic cable that can be used with a set of intra nasal, micro laryngeal hand pieces. These hand pieces allow for optimal laser focusing.
Light at its particular wavelength is absorbed by tissues relatively independent of tissue type. Tissue response at this wavelength is determined by the absorption of water as well as by absorption of endogenous components such as hemoglobin and melanin. As a result, the diode laser has a large (up to 10 mm) penetration depth in biologic tissue, which makes it ideal for photo coagulation. By contrast, the Co2 laser has a very shallow penetration depth and thus is best used for tissue vaporization.
The Berylas 15watts flexible fiber delivery system is compatible with hollow ENT handpiece allows for coaxial vision, and is ideally suited for intranasal, oral and micro laryngeal use.
Application techniques
1. It can be used in contact mode, in which the tip of the fiber is placed directly on the surface of the tissue. This mode is effective for both photocoagulation and vaporization of tissue, depending on the power density. At the low- or mid-power range, coagulation occurs; at a higher level, vaporization occurs.
2. The laser can be used in near-contact mode, in which the tip of the fiber remains several millimeters apart from the tissue. This mode is largely used for tissue photo coagulation.
3. The laser can be used for interstitial laser-induced thermotherapy, a minimally invasive method of treating both benign and malignant tumors. The laser is placed through puncture holes in the skin, and its energy is absorbed by local tissues. This hyperthermic state causes either immediate or delayed tissue necrosis via coagulation.
4. In the clinic most cases can be done after administering a topical anesthetic and a decongestant spray to the nasal cavity, but micro laryngeal surgery needs General anesthesia with special fleximetalic tube to prevent fire hazard.
Application of Diode Laser in ENT Surgery:
Turbinate reduction in case of allergic Rhinitis and Vasomotor Rhinitis
Cautery for Epistaxis, Telengiactasia, Osler-Weber-Rendu disease etc
Oral lesions- Leukoplakia , Erythroplakia
Releasing sub mucous fibrosis
Laser Cautery Tongue lesion
Tonsillotomy for Tonsillolith
Laser Granular pharynx
Myringotomy
LAUP-Snoring and OSA surgery
Microlaryngoscopy and removal of nodules, polyp etc under GA.
DCR with eye surgeons.
Laser Specification:
Laser Name | BERYLAS | |||
Laser Type | GaAlAs Diode Laser | |||
Wavelength | 810nm | 940nm | 810nm/980nm | 810nm+980nm/ 810nm+910nm |
Peak Power | 9watts | 15watts | 15watts/20watts | 15watts+15watts(30watts) |
Average power | 9watts | 15watts | 15watts/20watts | 20watts |
Operation Mode | CW, Single Or Repeat Pulse | |||
Pulse Duration | 10us- 3s | |||
Repetition Rate | 0.2Hz- 50KHz | |||
Pilot Beam | Red Diode Laser Of 650nm, Power<5mW | |||
Control Mode | True Color Touch Screen(7 inches,resolution 600*1024) | |||
Transmission System | Medical Fibers With SMA905 Connector | |||
Dimensions | 160(W)*180(L)*235(H) mm | |||
Weight | 2.1Kg |
Contact Us
- wuhan dimed laser technology
cherylas | enidlas | petlas | peralas |
HARLAS | BERYLAS | Class IV Laser Therapy | veterinary laser |
Surgical Laser |
- Mobile oxygen concentrator
- Plateau oxygen concentrator
- Pulse portable oxygen concentrator
- Ultra lightweight 9kg wheelchair
- Manual and electric wheelchairs
- Microwave remedial instrument Rehabilitation series products
- Red light therapy device Physical therapy equipment series products
- Breast therapy device Therapeutic equipment series products
- Pelvic inflammatory disease treatment device
- Ozone therapy device Therapeutic equipment series products
- Bohm light therapy device Therapeutic equipment series products
- Pelvic floor repair device Gynecological low-frequency pulse comprehensive treatment device
Popular Searches
- display devices
- Baby Incubator
- infant incubator
- infant radiant warmer
- infant phototherapy unit
- phototherapy unit
- Infant Baby Incubator
- Transport Baby Incubator
- Medical Infant Incubator
- Medical Baby Incubator
- Hospital Baby Incubator
- Therapy Equipment
- Camera Video
- physical equipment
- ion detox
- Therapy Massager
Find Similar Products By Category
- Health & Medical > Medical Devices > Physical Therapy Equipments
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-