Brand Name: | kenshine-pump | Place of Origin: | China | Model Number: | CHL2-35 |
Application: | Other, feed water,booster | Fuel: | Other, electric motor | Power: | Electric |
Usage: | Water | Theory: | Centrifugal Pump | Standard or Nonstandard: | Standard |
Structure: | Multistage Pump | Pressure: | High Pressure |
Product Description
CHL horizontal stainless steel centrifugal pump CHL Horizontal Stainless steel booster centrifugal Pump adopts stainless steel AISI304 or 316L, special in high pressure. Impeller, guide vane and all parts contact with liquid are of stainless steel punched and welded, so the flow road is very smooth and prevent producing second pollution. Shaft and sleeve are of hard alloy and adopt wear resistant mechanical seal, having super service time and no-leakage. Electrical motor adopt Y2 aluminum motor, importing bearing, insulation grade. Pumped Medium: |
Hot and cold clean, non-flammable and non-explosive liquid without solid grain and fiber. If for explosive liquid should choose explosion-proof motor.
Mineral water, soft water, pure water, edible oil and other light chemical mediums
When the density or viscosity of liquid is larger than that of water, it is necessary to select a driving motor of high-power
CHL Pump Application:
Urban water supply and pressure boosting
Industrial circulating system and processing system
Water supply for boiler, condensing system, high-rise building or fire fighting system.
Water treatment and infiltration system
Cooling water system
Many other domestic and industrial special applications
Motor:
Full-enclosed fan-cooled two-pole standard motor, 50HZ or 60HZ
Phase: Single-phase or three-phase, standard voltage or special voltage is available.
Protection class: IP55, Insulation class: F
Model | Head(m) | Flow rate (m3/h) | Motor power (KW) | Speed (r/min) |
CHL2-20 | 14 | 2 | 0.37 | 2900 |
CHL2-30 | 21 | 2 | 0.55 | 2900 |
CHL2-40 | 28 | 2 | 0.55 | 2900 |
CHL2-50 | 35 | 2 | 0.55 | 2900 |
CHL2-60 | 42 | 2 | 0.75 | 2900 |
CHL4-20 | 15 | 4 | 0.55 | 2900 |
CHL4-30 | 22 | 4 | 0.75 | 2900 |
CHL4-40 | 30 | 4 | 0.75 | 2900 |
CHL8-10 | 8.5 | 8 | 0.75 | 2900 |
CHL8-20 | 17 | 8 | 0.75 | 2900 |
CHL8-30 | 25.5 | 8 | 1.1 | 2900 |
CHL8-40 | 34 | 8 | 1.5 | 2900 |
CHL8-50 | 42.5 | 8 | 2.2 | 2900 |
CHL12-10 | 9.5 | 12 | 0.75 | 2900 |
CHL12-20 | 19.5 | 12 | 1.2 | 2900 |
CHL12-30 | 29.5 | 12 | 1.8 | 2900 |
CHL12-40 | 39.5 | 12 | 2.4 | 2900 |
CHL12-50 | 50 | 12 | 3 | 2900 |
CHL16-10 | 10 | 16 | 1.1 | 2900 |
CHL16-20 | 21 | 16 | 2.2 | 2900 |
CHL16-30 | 32 | 16 | 3 | 2900 |
CHL20-10 | 9.5 | 20 | 1.1 | 2900 |
CHL20-20 | 21 | 20 | 2.2 | 2900 |
CHL20-30 | 33 | 20 | 4 | 2900 |
CHLF(T)2-20 | 14 | 2 | 0.37 | 2900 |
CHLF(T)2-30 | 21 | 2 | 0.55 | 2900 |
CHLF(T)2-40 | 28 | 2 | 0.55 | 2900 |
CHLF(T)2-50 | 35 | 2 | 0.55 | 2900 |
CHLF(T)2-60 | 42 | 2 | 0.75 | 2900 |
CHLF(T)4-20 | 15 | 4 | 0.55 | 2900 |
CHLF(T)4-30 | 22 | 4 | 0.55 | 2900 |
CHLF(T)4-40 | 30 | 4 | 0.75 | 2900 |
CHLF(T)4-50 | 38 | 4 | 1.1 | 2900 |
CHLF(T)4-60 | 45 | 4 | 1.1 | 2900 |
CHLF(T)8-10 | 8.5 | 8 | 0.75 | 2900 |
CHLF(T)8-20 | 17 | 8 | 0.75 | 2900 |
CHLF(T)8-30 | 25.5 | 8 | 1.1 | 2900 |
CHLF(T)8-40 | 34 | 8 | 1.5 | 2900 |
CHLF(T)8-50 | 42.5 | 8 | 2.2 | 2900 |
CHLF(T)12-10 | 9.5 | 12 | 0.75 | 2900 |
CHLF(T)12-20 | 19.5 | 12 | 1.2 | 2900 |
CHLF(T)12-30 | 29.5 | 12 | 1.8 | 2900 |
CHLF(T)12-40 | 39.5 | 12 | 2.4 | 2900 |
CHLF(T)12-50 | 50 | 12 | 3 | 2900 |
CHLF(T)16-10 | 10 | 16 | 1.1 | 2900 |
CHLF(T)16-20 | 21 | 16 | 2.2 | 2900 |
CHLF(T)16-30 | 32 | 16 | 3 | 2900 |
CHLF(T)16-40 | 43 | 16 | 4 | 2900 |
CHLF(T)20-10 | 9.5 | 20 | 1.1 | 2900 |
CHLF(T)20-20 | 21 | 20 | 2.2 | 2900 |
CHLF(T)20-30 | 33 | 20 | 4 | 2900 |
CHLF(T)20-40 | 44.5 | 20 | 4.4 | 2900 |
Contact Us
- kenshine-pump
- Contact nameShine
- Phone86-0512-58583352
- AddressZhangjiagang free trade zone Suzhou,Jiangsu
- IS horizontal centrifugal water pump single stage end suction pump
- YW Submersible sewage not clogging centrifugal pump
- CQB-F fluoroplastic magnetic centrifugal pump
- CQ Stainless steel magnetic centrifugal pump
- ZA,ZAO,ZAE Petrochemical centrifugal pump
- FPG Vertical reinforced polypropylene centrifugal pump
- GWP Stainless steel vertical pipeline sewage pump
- JPWQ,JYWQ submersible sewage pump with automatic agitator
- AS/AV Submersible Sewage Pump With Shred Device
- WQK, Submersible sewage pump with cutting impeller
- QJ,QJP Deep Well Submersible Pump submersible multistage pump
- ZX Self priming centrifugal water pump
Popular Searches
Find Similar Products By Category
- Mechanical Parts & Fabrication Services > Pumps & Parts > Pumps
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Shine
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-