Home > Products > Line Post Insulator > Substation Post Transmission Line Insulator Composite 110 Kv High Flexibility
Substation Post Transmission Line Insulator Composite 110 Kv High Flexibility
- 0 Set / Sets per Month
- T/T L/C D/P D/A
- 7 days
- Chuanghui provides high-quality TA2 titanium alloy pipe heaters with high-precision, high-quality, and specialized technology
- Manufacturer Direct Sales Chuanghui TA2 Pure Titanium Titanium Alloy Pipe Electrolytic Electrode Condensing Agent
- Supply various specifications of Chuanghui titanium alloy pipe fittings, mechanical building decoration
- Titanium Pipe for Exhaust and Downpipe
- Titanium Pipe for Exhaust and Downpipe
- Titanium Pipe for Exhaust and Downpipe
Product Details
Brand Name: | Changgong | Place of Origin: | China | Model Number: | FZSW-110/5.7-1560 to FZSW-132/5.7-1560 |
Product Description
Certification:SGS KEMA STRI
Substation Post Transmission Line Insulator Composite 110 Kv High Flexibility
Specifications:
Dimensions and Characteristics of 110kV(132kV) line post insulator for Transmission Line
Figure. No | Model | Rated Voltage | Specified Cantilever Load | Section Length | Insulating length | Minimum Creepage | Full-Wave Impulse Withstand Voltage (Peak) | 1 Min Wet Power Frequency Withstand Voltage | Weight |
kV | kV | kN | h mm | L mm | ≥ kV | ≥ kV | kg |
||
6.1-1 | FZSW-110/5.7-1560 | 132 | 5.7 | 1560 | 1335 | 3880 | 660 | 276 | 31 |
6.1-2 | FZSW-132/8-1560 | 132 | 8 | 1560 | 1335 | 3880 | 660 | 276 | 31 |
Description:
1, 110kV(132kV) line post insulators are widely used in power transmission lines and substations.
2, Dead end fittings are up to the requirements from the clients, usually we use different flanges for post insulators with forged steel or cast steel. The dimensions and coupling size can be exactly according to the specification requirements from the utilities.
3, The silicon rubber color of the insulators are also up to the requirements from the clients and all the silicon rubber materials past 5000 hours aging test silicon content test and hydrophobicity test.
4, ECR core rods are used in all the insulators, so we can guarantee a very good mechanical strength and anti-acid pollution performance for the insulators.
5, All our insulators were type tested and design tested in accordance with IEC61952, maximum RIV is 100µV when tested at 1MHz and10% over nominal line ground voltage for indicated system voltage.
6, All the line post insulators with the voltage lower than 110kV are not supposed to use corona ring.
All the line post insulators with the voltage equal to or higher than 110kV but lower than 220kV are supposed to use one corona ring at the line end.
All the line post insulators with the voltage equal to or higher than 220kV are supposed to use two corona rings at both sides.
Applications:
1, 110kV(132kV) substations
2, 110kV(132kV) Electric Power Transmission Lines
Competitive Advantage:
1, Very good anti-pollution performance, no need to wash the insulators after the installation in lines.
2, Very convenient installation because of its light weight and one whole piece compared with glass insulators and ceramic insulators.
3, Excellent hydrophobicity characteristics can help to void flashover and guarantee the insulators with very good electric performance.