0.6S Highway Intelligent Automatic Boom Barrier Gate CE Approved
Certification:CE, ISO, SGS
0.6S Highway Intelligent Automatic Boom Barrier Gate CE Approved
Work with WONSUN
1.One year's free servicing is supplied( not including the arm)
2. Lifetiom charged servicing is offered.
3. Technology servicing is supplied
The following situations are charged for servicing (or changing):
1. Broken by wrong installation.
2 Broken by improper voltae.
3. The surfaces of the system destroyed by wrong installation our use.
4. Broken by natural disaster.
5. Overdue
6. Servicing items out of our promises.
The upgrade and improvement of the product won't be notified if there is any.
The explaining authority of this product instruction and service article belong to the production factory.
Model Selection and Differences
Specifications
|
Model |
WST1211 |
|
Working Temperature |
-40℃~+75℃ |
|
Voltage |
220V±10%, 110V±10%, 50/60HZ |
|
Rated power |
80W |
|
Relative humidity |
≤90% |
|
Remote control distance |
≥30m |
|
Net weight |
48kgs |
|
Speed |
1S,1.8S,3S, 6S |
|
Max boom length |
6 meters |
|
Motor Rotational speed |
1400rmp |
|
Protection Degree |
IP44 |
Communication with customers
1) Q: Connected power and press open/close button but traffic barrier gate no action?
|
A |
Reason |
Solution |
|
1 |
Fuse blown |
Check fuse and power in controller |
|
2 |
Battery of remote control powered off |
Change a new one |
|
3 |
External protection circuit break or at protecting status |
Open the barrier door and click OPEN/CLOSE button on control box |
|
4 |
Same frequency interference |
Check photocell and loop detector |
2) Q:Connected power and press open/close button,traffic barrier gate will move but even when it is at right position, the motor still running and not stop?
|
A |
Reason |
Solution |
|
1 |
Limit switch |
Adjust the horizontal/vertical limit switch to correct position |
|
2 |
Main controller failure |
Change a new one |
3) Q: Motor running but traffic barrier gate arm no action?
|
A |
Reason |
Solution |
|
1 |
Barrier arm at 45° position where is hard to move |
Unlock clutch and manually rotate arm to horizontal or vertical position then try again |
|
2 |
Tension of balancing spring not suitable |
Adjust spring exactly |
|
3 |
Low working voltage |
Check the voltage and power |
4) Q: When opening/closing,traffic barrier gate arm cannot reach right position (90° vertical & 180° horizontal)?
|
A. |
Reason |
Solution |
|
1 |
Length adjustment of connecting rod not correct |
Open barrier door and unlock clutch to check when arm at 90° vertical position if the master rod covers slave one; when arm at 180° horizontal position if master rod and slave one are in the same straight line |
Send Inquiry to This Supplier
You May Also Like
-
Actived Charcoal Filter CylinderNegotiableMOQ: 20 Sets
-
5L Hospital ECG Medical Ultrasound Coupling GelUS$ 0.1 - 1.1MOQ: 1 Carton
-
Animal Ultrasonic Detection Sets for Cow, Horse, Pets Etc. Palm ScannerNegotiableMOQ: 1 Set
-
U Fence Staples for Wooden Posts - 1.5 Inch Leg Length, Hot-Dip Galvanized, China FactoryNegotiableMOQ: 5 Tons
-
99 Cent Store Stationary China Product Cheap Plastic GlobeUS$ 0.05 - 0.3MOQ: 200 Pieces
-
High Quality Disposable Wooden Custom Medical Tongue Spatula DepressorUS$ 18 - 28MOQ: 10 Cartons
-
Needle Punched Qdsanhong and EVA Material Car Floor MatsUS$ 8.65 - 15MOQ: 1000 Pieces
-
Mini Coil With ROHS GEM008US$ 0.5 - 0.8MOQ: 1000 Pieces
-
Safety HammerUS$ 0.65 - 4.5MOQ: 1000 Pieces
-
YSSY-500 High Performance Low Price Hospital Medical Infusion PumpNegotiableMOQ: 1 Set