Car Park Management Systems Traffic Loop Detectors 20KHz ~ 170KHz
Certification:CE/ROHS/FCC/SGS
Vehicle Loop Detector PD-132
Power Supply: AC 220 V±10% Frequency range: 20KHz ~ 170KHz Sensitivity: 4 levels(adjustable) Reaction time: 10 ms Working temperature: -40ºC ~ +80ºC Relatie humidity: < 90% Enviroment compensation:automatic drift compensation Output method: relay Inductance:100uH ~ 300uH(recommended) Dimension:78x40x108 mm (L x W x H)Choose of the relay output
|
Relay 1 output |
DIP8=ON |
Forever exist: the relay 1 will keep closed/connected when the car stay above the loop until the car leaves the loop. |
|
DIP8=OFF |
10 mins exist: the relay 1 will keep closed/ connected for 10 mins when the car stay above the loop.After 10 mins, the detector turns back to the previous state. |
|
|
Relay 2 output |
DIP7= ON |
Leave impulse: when the car leaves the loop, the output relay2 will close/connect for 0.5S and then open/disconnect. |
|
DIP7= OFF |
Enter impulse: when the car enters the loop, the output relay2 will close/connect for 0.5S and then open/disconnect. |
nstallation of detector
The detector must be installed in a position where far away from humidity, heat and magnetic. Keep a distance of 10 mm (the detector surface and cabin surface).And the detector should be installed in a vertical position in the cabin.
■ Interface wiring
1,2 pins connected to power ,7,8 to loop,3,4 to output of relay 2,5,6 to output of relay 1.
■ Reset
The detector will be reseted to no-car state when the detector is power-on or when the DIPs of the sensitivities are modified.
■ Working State indication
When the power is on, the detector will calibrate automatically for 3 seconds. The green light on the board will flash and then extinguish. When a car goes through the loop, the green light shines. The relay1 (pin 5,6)connect and close. When the loop is not detected or short circuit happen, the green light will keep flashing.
■ Sensitivity Adjustment
Sensitivity is used to adjust the speed of the detecting of the vehicles. The DIP3 and 4 are used to modify (as the picture show).Use the low sensitivity level in the beginning of the set, and then turn up the levels as the actual need.
Notice:Carefully use the High level. When the loop circles is few, and the level is high..The detector will respond too fast in this state. Consequently, the detector will output a false signal (detect the free space as an occupied space)
Send Inquiry to This Supplier
You May Also Like
-
Actived Charcoal Filter CylinderNegotiableMOQ: 20 Sets
-
5L Hospital ECG Medical Ultrasound Coupling GelUS$ 0.1 - 1.1MOQ: 1 Carton
-
Animal Ultrasonic Detection Sets for Cow, Horse, Pets Etc. Palm ScannerNegotiableMOQ: 1 Set
-
U Fence Staples for Wooden Posts - 1.5 Inch Leg Length, Hot-Dip Galvanized, China FactoryNegotiableMOQ: 5 Tons
-
99 Cent Store Stationary China Product Cheap Plastic GlobeUS$ 0.05 - 0.3MOQ: 200 Pieces
-
High Quality Disposable Wooden Custom Medical Tongue Spatula DepressorUS$ 18 - 28MOQ: 10 Cartons
-
Needle Punched Qdsanhong and EVA Material Car Floor MatsUS$ 8.65 - 15MOQ: 1000 Pieces
-
Mini Coil With ROHS GEM008US$ 0.5 - 0.8MOQ: 1000 Pieces
-
Safety HammerUS$ 0.65 - 4.5MOQ: 1000 Pieces
-
YSSY-500 High Performance Low Price Hospital Medical Infusion PumpNegotiableMOQ: 1 Set