Home > Health & Medicine > Medical Supply > Disposable Medical Supplies > Copper Bare Aluminium Conductor With XLPE Sheath 6Awg ~ 266Awg 0.6 / 1KV

Copper Bare Aluminium Conductor With XLPE Sheath 6Awg ~ 266Awg 0.6 / 1KV

Copper Bare Aluminium Conductor With XLPE Sheath 6Awg ~ 266Awg 0.6 / 1KV photo-1
US$ 50 - 80 MOQ: 1 Kilogram
Key Specifications
Get Latest Price
Brand Name:
Sunlight
Place of Origin:
China
Model Number:
JKLYJ 6Awg~ 266Awg 0.6/1KV
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
7 days
Brand Name Sunlight
Place of Origin China
Model Number JKLYJ 6Awg~ 266Awg 0.6/1KV
Delivery Time:25-40 Days
Certification:ISO 9001:2008, TLC, CCC

Copper Bare Aluminium Conductor With XLPE Sheath 6Awg ~  266Awg 0.6 / 1KV

Quick Detail:

Copper Bare Conductor with XLPE Sheath 

1.Low Voltage Copper Conductor

2.Black XLPE Outer sheath

3.Single Core 

Description:

1. Copper Bare Conductor with XLPE Sheath
2. Construction of ABC Cable
Conductors are aluminum alloy 1350H19, 6201181, or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene (HD) or crosslinked polyethylene (XLP).
3. Standards of ABC Cable

· ASTM B-230 - Aluminum 1350-H19 Wire for Electrical Purposes

· ASTM B-231 - Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).

· ASTM B-1248 - Polyethylene Plastics Molding and Extrusion Materials.

· ASTM C-8.35 - Specifications for Weather-Resistant Polethylene-Covered Wire and Cable.

· ICEAS-61-402

· NEMA PUB NO. WC 5-1973 - Standards Publication Thermoplastic insulated Wire and Cable 

  for the Transmission and Distribution of Electrical Energy.



Notes

· The code words as given apply to conventional polyethylene line wire.

· For 6201 aluminum conductors diameter equivalent to ACSR construction or 1350 aluminum equivalent.

· Ampacity ratings based on 75oC conductor temperature, 25oC ambient temperature elevation sea level. 

  Emissivity 0.91 coefficient of absorption 0.95. Thermal reisitivity of covering -375oC-    Cm2/Watt-CM. Wind speed 2ft/sec in sun.

· To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition. 

Item

Size
AWG or MCM

Insulation
Thickness
(mils)

Outside
Diameter

Rated
Breaking
Strength

Weight
Per
MFT
XLP

Weight
Per
MFT
POLY

Ampacity
XLP

Walnut

6

30 mls

.258 Inches

1131 Lbs

49 Lbs

47 Lbs

105 Amps

Butternut

4

30 mls

.303 Inches

1170 Lbs

71.8 Lbs

70.0 Lbs

135 Amps

Hickory

4

30 mls

.309 Inches

2240 Lbs

81.6 Lbs

79.8 Lbs

135 Amps

Pignut

2

45 mls

.397 Inches

2710 Lbs

118.1 Lbs

114.8 Lbs

180 Amps

Beech

2

45 mls

.405 Inches

3460 Lbs

134.1 Lbs

130.7 Lbs

180 Amps

Chestnut

1

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Total Employees
101 - 200 People
Main Markets
North America, South America, Eastern Europe
Location
Hangzhou, Zhejiang, China

Recommended Categories

Explore top categories and find suppliers for your specific needs