Sell Wholesale Submersible Water Pump
Working conditions: 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 1. 380V (deviation≤5%), 50Hz (deviation≤1%), 3 phases 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 2. Electric motor must be full of clean water 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 3. The first piece of impeller of pump should be at least 2m or more below dynamic water level. The distance from Pump to static water level should be not more than 70m. The distance from motor base to well bottom should be not less than 3m. 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 4. Water temperature should be not more than 20°C 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 5. Sand content of water (based on mass of sand) should be not more than 0.01% 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 6. PH should be 6.5-8.5 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 7. The content of hydrogen sulfide in water should be not more than 1.5mg/l 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 8. The content of chloride ions should be not more than 400mg/l 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 9. Water yield of water source should satisfy the demand of pump running.
18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> Installation of pump: 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> Pump whose lift is less than 30 meter, flexible pipe can be used to match. Such pump can be hoisting installation in the well straightly by steel wire or other rope (as long as it can bear the total weight of whole pump, pipe and water in pipe, it will be ok) 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> Pump whose lift is more than 30 meter, steel tube will be used to match. The detailed installation steps are as followings: 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 1) Chucking the upper part of pump by clamp (motor has been connected with pump well), and hoist pump by sling chain and put pump into well slowly till clamp is on the wellhead, then detach the sling chain. 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 2) Chucking one piece of pipe by another pair of clamp, and hoisting the pipe at the point of 15cm away from flange by clamp, and then put down slowly. Please pad rubber mat well between pipe flange and pump flange, and tighten the connecting point of pipe and pump by bolt, nut and spring. 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 3) Hoisting pump a little and detach the clamp from the upper of pump, and then fastening electric cable on the water pipe by plastic tape. Next, put down slowly till the clamp is on the wellhead. 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 4) Fastening other pipes in the well by same way as above. 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 5) Connecting electric cable to controlled switch, and access power. 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\">
Send Inquiry to This Supplier
You May Also Like
-
Spot Danfoss Piston Pump JR-L-S75C-LS-21-25-NN-N3-S1NE-A2NNNN-JJ J-NNNNegotiableMOQ: 1 Piece
-
M, AH, HH Series Slurry PumpNegotiableMOQ: 1 Piece
-
304 Stainless Steel Industrial Water Pump 220V 50Hz 3HPUS$ 10000MOQ: 1000 Tons
-
Japan Komatsu PC200-8 PC210-8 PC220-8 Excavator 708-2L-31430 Hydraulic Main Pump 7082L31430US$ 4000 - 5000MOQ: 1 Unit
-
Rexroth PGF1-21/1.7RA01VP1 Type Hydraulic Internal Gear PumpUS$ 120.36 - 229.87MOQ: 1 Set
-
Innovative CMO GHIBLI FOOT PUMP Industrial Solutions for Enhanced PerformanceNegotiableMOQ: 1 Set
-
Manufacturer Direct Selling Fluorine Lined Strong Acid and Alkali Resistant Pump IHF Series Fluorine Plastic Alloy Chemical Centrifugal PumpUS$ 150 - 1600MOQ: 10 Pieces
-
Sand Pumping PumpUS$ 410 - 700MOQ: 1 Piece
-
Micro Machining Precision Casting Water Pump Spare PartsUS$ 1 - 30MOQ: 500 Pieces
-
Parts Of Breast PumpUS$ 1,000 - 1,100MOQ: 2 Tons