250QJ Centrifugal Submersible Water Pump
Technical Parameters: 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\">
speed Pump
efficiency pipe
diameter Rated Range Rated Range QJ Series m3/h m3/h m m r/min % mm 250QJ140-15/1 140 130-150 15 14-16 2875 76 140 250QJ140-22/1 22 21-23 250QJ140-30/2 30 29-31 250QJ140-45/3 45 43-47 250QJ140-60/4 60 57-63 250QJ140-75/5 75 72-78 250QJ140-90/6 90 86-94 250QJ140-105/7 105 100-110 250QJ140-120/8 120 115-125 250QJ140-135/9 135 129-141 250QJ140-150/10 150 144-156 250QJ140-165/11 165 158-162 250QJ140-180/12 180 172-188 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> Working conditions: 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 1. 380V (deviation≤5%), 50Hz (deviation≤1%), 3 phases 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 2. Electric motor must be full of clean water 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 3. The first piece of impeller of pump should be at least 2m or more below dynamic water level. The distance from Pump to static water level should be not more than 70m. The distance from motor base to well bottom should be not less than 3m. 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 4. Water temperature should be not more than 20°C 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 5. Sand content of water (based on mass of sand) should be not more than 0.01% 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 6. PH should be 6.5-8.5 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 7. The content of hydrogen sulfide in water should be not more than 1.5mg/l 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 8. The content of chloride ions should be not more than 400mg/l 18px arial, helvetica, sans-serif; word-wrap: break-word; white-space: normal; orphans: 2; letter-spacing: normal; color: rgb(51,51,51); word-spacing: 0px; padding-top: 0px; -webkit-text-size-adjust: none; -webkit-text-stroke-width: 0px\"> 9. Water yield of water source should satisfy the demand of pump running.
Send Inquiry to This Supplier
You May Also Like
-
Spot Danfoss Piston Pump JR-L-S75C-LS-21-25-NN-N3-S1NE-A2NNNN-JJ J-NNNNegotiableMOQ: 1 Piece
-
M, AH, HH Series Slurry PumpNegotiableMOQ: 1 Piece
-
Explosion-Proof Slurry Pump for Mining Operations With 1-Year WarrantyNegotiableMOQ: 10 Acres
-
Water PumpNegotiableMOQ: 2300 Pieces
-
Japan Komatsu PC200-8 PC210-8 PC220-8 Excavator 708-2L-31430 Hydraulic Main Pump 7082L31430US$ 4000 - 5000MOQ: 1 Unit
-
Innovative CMO GHIBLI FOOT PUMP Industrial Solutions for Enhanced PerformanceNegotiableMOQ: 1 Set
-
Manufacturer Direct Selling Fluorine Lined Strong Acid and Alkali Resistant Pump IHF Series Fluorine Plastic Alloy Chemical Centrifugal PumpUS$ 150 - 1600MOQ: 10 Pieces
-
Micro Machining Precision Casting Water Pump Spare PartsUS$ 1 - 30MOQ: 500 Pieces
-
Parts Of Breast PumpUS$ 1,000 - 1,100MOQ: 2 Tons
-
High Quality Oilfield 11kw-50kw Centrifugal PumpNegotiableMOQ: 1 Set