UNIVERSAL 6241F SMTpart

UNIVERSAL 6241F SMTpart photo-1
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Brand Name:
Place of Origin:
China
Model Number:
6241F
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
7 days
Place of Origin China
Model Number 6241F
         
If Board is selected, the Board Error Correction dialog box is displayed. 
           
         
If Circuit 1 is selected, the Circuit Error Correction: Circuit 1 dialog box is displayed. 
3          
         
To use insertion locations, select the insertion from the Ref ID (Component ID) list box and select the Add button. The selected insertion is copied to the Error Correction list box. 
         
To define correction locations not related to a specific insertion, enter the coordinates in the X Position and Y Position entry fields and select the Add button. The coordinates are copied to the Error Correction list box. 
Up to three locations can be defined for a BEC step. Selecting the Add button defines a BEC location. Selecting OK defines a BEC step. Any number of BEC steps can be defined per circuit per rotation. 
If defining Circuit Error Correction locations, to have the locations de-fined on all associated offsets of the circuit, select the Define for Off-set Circuits checkbox (checkmark visible). If the checkbox is cleared, the locations are only defined for the selected circuit. If defin-ing Board Error Correction locations, this checkbox is disabled. 
To define correction locations on rotations other than table rotation 0°, select the desired rotations from the Perform Correction at Table Rotation(s) group box. Only rotations that have insertions are en-abled. 
           
         
If correction locations are defined that cannot be reached at one or more table rotations, an error message similar to the following is displayed. 
         
If an insertion location from the 0° table rotation is selected as a correction for the 90° table rotation, an error message similar to the following is displayed. 
This means that the hole selected for the correction at the 90° table rotation is already populated with the component so the correction cannot be performed. 
Select OK.         
4          
         
Two insertions selected for a board.   
         
           
Two locations selected for a board.   
. Two Insertions selected for a circuit.   
         
Two locations selected for a circuit.   
5          
Change Correction Locations     
To change an existing correction location:   
1          
Use the right trackball (mouse) button to select the Circuit or Board Error Correction step to be edited. A pop-up menu is displayed. 
2          
           
Select Edit from the pop-up menu. The Board (or Circuit) Error Cor-rection dialog box is displayed. The current correction locations are displayed in the Error Correction list box. 
In the example, step 1 uses r1 [diode-axial] in circuits 1, 3, and 
4          
3          
From the Error Correction list box, select the location(s) to be edited. 
4          
Select Remove to delete the location from the list box. 
5          
Select another insertion or enter position coordinates and select Add. 
6          

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
Business Type
Trading Company
Total Employees
101 - 200 People
Main Markets
North America, South America, Eastern Europe
Location
Baoji, Shaanxi, China

Recommended Categories

Explore top categories and find suppliers for your specific needs