380V 589--942 CFM Air To Air All Heat Exchanger Recovery in Plate Ventilation From Factory Supplying for Air Recuperator
Energy Recovery Ventilator
Item No:K-16D
Specification
Air volume can not be changed with controller. Rated air flow
Model type: Heat & Humidity
Airflow: Cross flow
Static pressure: 100--180Pa
Air volume: 1000--1600m3/h
Noise: 42--48dB(A)
Exchanger core material: fiber paper
Function: Outdoor & indoor air exchanger
Place: Home/office/meeting room/factory room/ farm
Surface stick: Silencers cotton
Size:1350x1220x437 (mm)
Power:415---650 (w)
Rated voltage:380V
Temperature efficiency:70%--75%(summer)70%--75%(winter)
Enthalpy efficiency:51%--56%(summer)60%--65%(winter)
Weight:98kg
Features
- Built-in high-performance heat exchanger unit, rectangular channel structure, the discharge to the indoor air and send them to achieve indoor air exchange heat and humidity during the flow of the plate, and recovering energy in the provision of air at the same time a suitable temperature, Energy saving
- Wind range 150--1000m3 / h, suitable for houses, villas, offices, schools, factories, workshops, farms and other places
- Units installed in the ceiling, do not take up interior space efficient, it does not affect the interior decoration effect
- The core and the device using a molding rail connection and equipped with soft sealing materials, ensure to prevent contamination of fresh air ventilation to ensure the quality of fresh air, and the core can be disassembled without tools, just open any access door can be repaired, convenient simple
- Optimized structure design, according to the hydrodynamic optimization design of internal air flow path and the high efficiency of the overall housing sound-absorbing materials, non-metallic impellers, precise mold production, to ensure perfect acoustics
- In addition to have two-way ventilation, air purification, energy recovery and other basic functions, the unit also set a bypass function, two-speed adjustment function, and you can choose to configure Intelligent Control System
Product description:
KRV series stand for energy recovery ventilator, the heat exchanger core is cross flow paper core, the major function is remove the exhaust air(stable indoor air) and replace it with fresh outdoor air, improve the air quality. It is suitable for installation in Home, office, meeting room. Not only exchanger fresh air, but also save energy.
Features:
1.Indoor and outdoor two-ways ventilation, equivalent exchanger of fresh air;
2.Low noise, corrosion and high tempreture resistant;
3.Paper core:high moisture-permeating rate, good air-tightness, tearing-resistance and aging-resistance
4.High heat recovery efficiency;
5.Sealed process stucture,easy to contral and maintain
Main parameter:
Model | Air Volume (m3/h) | Static Pressure (Pa) | Rated Voltage | Input Power (W) | Summer | Winter | Noise | Dimension (mm) | Re. weight (kg) | ||||||||||
TemperatureEfficiency (%) | Enthalpy Efficiency (%) | Temperature Efficiency (%) | Enthalpy Efficiency (%) | ||||||||||||||||
High | Low | High | Low | High | Low | High | Low | High | Low | High | Low | High | Low | High | Low | ||||
K-02DT | 200 | 150 | 75 | 65 | 220V/50Hz | 80 | 58 | 75 | 77 | 58 | 62 | 75 | 77 | 69 | 72 | 30 | 27 | 665×580×268 | 26 |
K-03 DT | 300 | 250 | 85 | 75 | 220V/50Hz | 107 | 78 | 76 | 77 | 56 | 60 | 76 | 77 | 67 | 70 | 32 | 29 | 745×600×268 | 32 |
K-04 DT | 400 | 350 | 90 | 80 | 220V/50Hz | 142 | 121 | 76 | 77 | 54 | 58 | 76 | 77 | 66 | 68 | 34 | 30 | 745×800×268 | 38 |
KRV energy recovery ventilator Work principle:
Ceil Installation, save space:
WELcome to visit Energy recovery ventilator
Send Inquiry to This Supplier
You May Also Like
-
90--380M3/H Air To Air All Heat Exchanger for Plate Ventilation Supplying for Air RecuperatorUS$ 350 - 800MOQ: 1 Set
-
Lates Technology Power Saver 90--320M3/H Air To Air All Heat Exchanger for Recovery in Plate Ventilation for Air RecuperatorUS$ 350 - 800MOQ: 1 Set
-
800--1000 M3/H Air To Air All Heat Exchanger for Recovery Plate Ventilation for Air RecuperatorUS$ 350 - 800MOQ: 1 Set
-
600--800M3/H Air To Air All Heat Exchanger for Energy Recovery in Plate Ventilation for Air RecuperatorUS$ 350 - 800MOQ: 1 Set
-
500--600M3/H Air To Air All Heating Energy for Recovery Plate Ventilation for Air RecuperatorUS$ 350 - 800MOQ: 1 Set
-
300--400 M3/H Air To Air All Heating Energy for Air RecuperatorUS$ 350 - 450MOQ: 1 Set
-
Air To Air Energy Recovery Plate for Air RecuperatorUS$ 450 - 1,000MOQ: 1 Piece
-
EC Motor Power Saving Heat Recovery Recuperator SystemUS$ 429 - 598MOQ: 1 Set
-
Room Use Total Heat Exchange Energy Recovery VentilatorNegotiableMOQ: 1 Piece
-
Hotel Ceiling Fresh Air Heat Exchanger Ventilator HRVUS$ 350 - 350MOQ: 1 Piece