Heat Recovery Ventilation With Heat Recovery
Heat Recovery Ventilation with Heat recovery
AIR-ERV heat recovery ventilation units , designed for saving energy and also improving indoor air quality.
AIR-ERV heat recovery ventilation units provide heat recovery and well conditioned fresh air by air to air plate type exchanger and heat pump.
30°C fresh air in the summer time and 12°C fresh air in the winter time can be obtained by usual heat recovery units,
but these results are not comfortable. You can cbtain 20°C fresh air in the summer time and
12°C fresh air in the winter with high efficiency heat pump.
• 5 standard models with TSEK certifcation
• Conditioned fresh air, with a temperature of 20°C in summer and 25°C in winter
• Compact structure (fresh air fan + exhaust air fan + plate type heat exchanger +evaporator +
condenser + compressor + cooling equipments)
• High quality indoor air with synthetic filter
• The design, providing fast and easy installation and maintenance
• Low noise level and working on required capacity by using direct driven fan with 5 speeds
• The high conductivity and performance, aluminum plate type heat recovery exchangers
DX Controller is supplied with the heat-pump heat recovery unit as standart.There are 4 different modes;
• FAN mode: Only the fans runs and heat is transferred over the plate heat exchanger. Compressor does not run.
• COOL mode: Compressor runs and cools the air by regarding to the room set temperature.
• HEAT mode: Compressor runs and heats the air by regarding to the room set temperature.
• AUTO mode: The unit runs and operates cooling, heating or only fan by regarding to the room set temperature.
Heat Recovery Ventilation with Heat recovery Size and performance
Model |
Air Volume (m3/h) |
Static Pressure (Pa) |
Volts/Hz |
Input Power ( W ) |
TemperatureEfficiency ( % )
|
Noise |
Dimension (mm) |
||||||
High |
Low |
High |
Low |
High |
Low |
High |
Low |
L |
W |
H |
|||
HRV-02DT |
200 |
150 |
70 |
75 |
220V/50Hz |
70 |
55 |
77 |
30 |
27 |
665 |
580 |
293 |
HRV-03 DT |
300 |
150 |
50 |
50 |
220V/50Hz |
105 |
75 |
77 |
32 |
29 |
745 |
600 |
293 |
HRV-04 DT |
400 |
250 |
75 |
50 |
220V/50Hz |
155 |
105 |
78 |
34 |
30 |
745 |
800 |
293 |
HRV-06 DT |
500 |
300 |
100 |
70 |
220V/50Hz |
190 |
150 |
76 |
35 |
32 |
820 |
900 |
293 |
HRV-08 DT |
800 |
600 |
120 |
100 |
220V/50Hz |
410 |
295 |
76 |
37 |
35 |
1110 |
880 |
413 |
HRV-10 DT |
1000 |
700 |
80 |
80 |
220V/50Hz |
435 |
330 |
75 |
38 |
36 |
1110 |
1135 |
413 |
Send Inquiry to This Supplier
You May Also Like
-
Roof Air Ventilation SystemUS$ 50 - 500MOQ: 10 Sets
-
Cabinet VentilationUS$ 1 - 5,000MOQ: 10 Sets
-
Family Tubular Heat ExchangerUS$ 50 - 500MOQ: 10 Sets
-
Base Station Air ConditionerUS$ 1 - 5,000MOQ: 10 Sets
-
Air Ventilation FanUS$ 50 - 500MOQ: 10 Sets
-
Heatexchanger for Base StationUS$ 1 - 5,000MOQ: 10 Sets
-
Roof Ventilation SystemUS$ 50 - 500MOQ: 10 Sets
-
Plate HeatexchangerUS$ 1 - 5,000MOQ: 10 Sets
-
Basement Ventilation SystemUS$ 50 - 500MOQ: 10 Sets
-
Base Station VentilatorUS$ 1 - 5,000MOQ: 10 Sets