Hot Selling CO2 Detector for HVAC,BAS
Specifications
Real-time monitoring carbon dioxide (CO2) measurements during 0 to 20,000ppm rangeOptional real-time monitoring temp.,RH%
F2000IAQ-CO2 detector/Indicator is used to monitor and alarm CO2 level and room temperature. Relative humidity detection and display can be as an option. Other options can be provided to users: RS485 communication interface with independent address; one dry contact output to control a ventilation device.
Especial design for schools, kindergartens, office buildings, conference rooms, rest rooms as well as other public places
u Built-in NDIR CO2 module, 15 years long life.
u ABC Logic self calibration algorithm for CO2 sensor.
u Real-time detect and display room CO2 and temperature
u 3 LED indicator lights following three different CO2 ranges to indicate
ambiance ventilation situation: Optimal Ventilation; Poor Ventilation and Insufficient Ventilation.
u Optional humidity detection and display
Features
u Real-time detecting and display CO2 level during 0ppm to 20,000ppm CO2 range; Also detecting room temperature from 5 to 45°C
u Optional real-time humidity from 5%RH to 95%RH
u NDIR CO2 sensor technology of infrared self diffusion, 15 years lifetime
u Self Calibration Algorithm makes it in using without calibration amending
u The three measured CO2 ranges for 3-LED indicator lights selectable by end users
u LED’s brightness adjustment
u Optional 1X dry contact output or one 0~10VDC output to control a ventilation device
u Easy preset CO2 level for buzzer alert (optional)
u Optional RS485 interface to connect to a PC or another system (optional)
Specifications
Gas detected |
Carbon Dioxide (CO2) |
Sensing element |
Non-Depressive Infrared Detector (NDIR) |
Temperature sensor |
NTC |
Temperature correction |
Self compensation |
CO2 NDIR life |
15 years |
Consumption |
3.5W/ Max, 2.5W/ Average |
Accuracy@25°C(77°F) |
±40ppm + 3% of reading |
Stability |
<2% of FS over life of sensor (15 yr typical) |
Warm up time |
2 hours (first time) 2 minutes (operation) |
CO2 measuring range |
0~2000ppm, which is default value 0~(1,000~20,000)ppm, programmable selection |
CO2 setting & Display resolution |
1ppm |
Temperature measuring range |
0~50°C(32~122°F) |
Temperature setting range |
5~45°C(41~113°F) |
Option: 1X dry contact output |
Rated currency for contact point: 3A220VAC/30VDC, resistance load |
Option: RS485 communication interface |
9600/14400/19200(default)/28800/38400bps rates selectable by program,15KV protection for static, independent address setting |
Operation condition |
0~50°C (32~122°F), 0~95%RH without condensing |
Power supply |
220VAC/110VAC or 24VAC 50/60HZ±10% |
Weight |
380g |
Dimensions |
130mm×90mm×40mm |
Connections Interface |
Locate in interface of connection |
Installment standard |
65mm×65mm or 2”×4” wire box |
Wiring standard |
Wire section area<1.5mm2 |
Approval Standard |
CE-Approval |
Programming and selection |
DIP switches inside and external push-buttons |
Model Guide
Gas Type |
|
CO2 |
Carbon Dioxide |
Code |
Model |
|
3 |
1 |
Standard model (CO2 &temperature detection) |
5 |
1 |
CO2 &temperature detection with RS-485 network communication |
Code |
Analog output |
0 |
No analog output |
1 |
1X 0~10V output |
Code |
Dry contact output |
0 |
No dry contact output |
1 |
1X dry contact output |
Code |
Humidity option |
RH |
Relative humidity detection |
Code |
Power supply |
A |
220/240VAC |
B |
100/120VAC |
C |
24VAC |
F2000IAQ |
CO2 |
— |
X1 |
1 |
X2 |
X3 |
— |
Y1 |
— |
Y2 |
Note: X2 + X3≤1
Example: F2000IAQ-CO2-3100 indicates that it is a CO2 indicator with temperature detection.
Send Inquiry to This Supplier
You May Also Like
-
CJG10, CJG100 Optical Interference Type Methane DetectorUS$ 150 - 200MOQ: 1 Piece
-
Honeywell SiF4 Gas Detector MIDAS-E-HFX MIDAS-K-HFX Original and NewNegotiableMOQ: 1 Piece
-
LD 200 Halogen Gas Freon CFCs HCFCs HFCS HFO Refrigerant Leak Detector LD-200NegotiableMOQ: 1
-
High Quality Gas Leak DetectorNegotiableMOQ: 1 Piece
-
Dual Digital Breath Alcohol TesterNegotiableMOQ: 2000 Pieces
-
Sulfur Hexafluoride SF6 Recycling Device With Function of SF6 FillingUS$ 2,000 - 50,000MOQ: 1 Set
-
Factory Offer NO Gas Detector OEM Gas DetectorUS$ 400 - 600MOQ: 10 Sets
-
BrACAudit Panther-3 (with Camera, Built-in Printer) Breath Alcohol AnalyzerUS$ 568.00 - 568.00MOQ: 3 Pieces
-
CALIBRE Ethylene Golycol Tester Antifreeze TesterNegotiableMOQ: 1020 Pieces
-
Industria Online Portable Gas TesterUS$ 250 - 300MOQ: 1 Unit