Programmable CO2 Controller
Specifications
1.CO2 monitor with Temperature & Humidity Detection2. 0~10V output or relay output optional
3.RS485 optional
Gas detected |
Carbon Dioxide (CO2) |
Sensing element |
Non-Dispersive Infrared Detector (NDIR) |
Temperature sensor |
NTC |
Humidity sensor |
HS series capacitive sensor |
Temperature dependence |
0.2% FS/°C |
Temperature correction |
Self compensation |
Power supply |
24VAC/VDC, or 100~240VAC, 60HZ, selectable with the order |
Consumption |
3.5 W max. ; 2.5 W avg. |
Accuracy@25°C(77°F) |
±30ppm + 3% of reading |
Stability |
<2% of FS over life of sensor (15 yr typical) |
Calibration interval |
ABC Logic Self Calibration Algorithm |
Non linearity |
<1% of FS |
Pressure dependence |
0.13% of reading per mm Hg |
Altitude calibration |
Programmable from 0-9,900m in 100m increments |
Response Time |
<2 minutes for 90% step change |
Signal update |
Every 2 seconds |
Warm up time |
2 hours (first time) 2 minutes (operation) |
CO2 measuring range |
0~2,000ppm (default) 0~20,000ppm, programmable selection 0~50,000ppmt |
CO2 setting & Display resolution |
1ppm |
Temperature measuring/ setting range |
0~50°C(32~122°F)/ 5~45°C(41~113°F) |
|
|
|
|
Humidity measuring/setting range |
0~99%RH/ 5~95%RH |
Analog output |
0~10VDC linearized output or PID control output, selectable by end users |
Output resolution |
10Bit |
Relay output |
One or two dry contact outputs with programmable selection to control CO2, temperature, humidity Rated switching current: 3A(220VAC/30VDC), resistance load |
Communication interface |
RS-485, 9600/14400/19200(default)/28800 or 38400bps (programmable selection), 15KV antistatic protection, 3 independent base address, max network node 64 |
Flow rates |
Diffusion version 80 ~ 120 cc/min Flow through version 40~50cc/min |
Operation conditions |
0~50°C(32~122°F); 0~95%RH, |
Storage conditions |
-10~60°C(14~148°F)/5~90%RH non condensing |
NDIR life |
15 years |
Weight |
360g |
Dimensions |
130mm×90mm×40mm |
Installment standard |
65mm×65mm or 2”×4”wire box |
Interface connections |
Maxi. 9 terminals |
Wiring standard |
wire section area<1.5mm2 |
Approval Standard |
CE-Approval |
Programming and selection |
Via internal jumpers and push-buttons on the panel |
1) Design for HVAC, ventilation systems, offices, classrooms or other application places.
2) Real-time detecting CO2 level. Temperature and humidity detection is optional.
3) NDIR infrared CO2 module inside with four CO2 detection range selectable.
4) CO2 sensor has Self-Calibration Algorithm and 15 years lifetime
5) Mounted type and duct type selectable
6) Special 6 lights Indicates CO2 level and makes it clear show.
7) Special model with a touch button as a controller to operate a fan control.
8) Providing up to three analog outputs for CO2/temperature/humidity.
9) One relay output is available
10) RS-485 communication interface is optional: 15KV antistatic protection, independent address setting
11) 24VAC/VDC power supply can be connected with the wire terminals, also a power adaptors plug connected into the socket available.
12) CE-Approval
Send Inquiry to This Supplier
You May Also Like
-
Endress+Hauser E+H Compact Conductivity Device Smartec CLD18-BGGENegotiableMOQ: 1 Piece
-
Universal Testing MachineNegotiableMOQ: 2500 Pieces
-
Hydraulic Plastic Flange Connections Cover Plugs SHF SeriesUS$ 0.22 - 0.28MOQ: 2500 Pieces
-
HST Spring Dyno Friction Leakage Fatigue Testing MachineUS$ 5000 - 10000MOQ: 1 Set
-
Gates 550C 550U U550 U-550 U508 U-508 Japan Unitta U-550 Belt Tension Meter New U-508 Belt Tension Meter Upgraded Version U550US$ 1 - 900MOQ: 1 Piece
-
Analytical Balanace.scale ,weichengya Laboratory SupplierUS$ 10 - 35MOQ: 10 Sets
-
Smart MD-3051 Online Density Meter With 4-20mA OutputUS$ 2,380 - 2,500MOQ: 1 Unit
-
5W-300W Sun Simulator Watt Testing 30% Off / Xenon Lamp Sun Simulator Free Sent / Sun Simulator TestingUS$ 7,500 - 10,000MOQ: 1 Set
-
New Design Measuring Meter With Best PerforanceUS$ 1,000 - 1,200MOQ: 1 Piece
-
XK-1 Rotary Switch Life TesterNegotiableMOQ: 1 Set