CO2 Controller for Greenhouse,hyfdroponics,agriculture
Specifications
1. Monitoring and control room CO2 level,as well as temperature and humidity.2.CO2 Controller for agriculture application.
CO2 controller for greenhouse,hydroponics,agriculture
Features
u Especially designed for agriculture equipments such as greenhouses, food and vegetable storages. Real-time detecting CO2 level, temperature and humidity with the local programmable control.
u Wall mounting, LCD display
u Carbon dioxide sensor, temperature sensor and humidity sensor are internal. The three values can be apart set.
u Non-Dispersive Infrared Detector (NDIR) CO2 sensor, 15 years lifetime, CO2 setting range is selectable: 0~2000ppm / 0~20000ppm / 0~50000ppm
u Special ABC Logic with patented Self Calibration Algorithm makes the CO2 sensor used up to 15 years
u Temperature setting range: 5~45°C
Humidity setting range: 5~95%RH
u Provide three relays outputs to control a CO2 generator, a temperature device and a humidity devise or a ventilator.
u Special photosensitive sensor detection can make the working mode of the CO2 generator changeover automatically in day and night.
u Provide brightness adjustment range to make day/night limit setting by end users.
u RS-485 communication interface with 15KV antistatic protection makes the controller being connected with PC (option)
u Multiple functions, high performance, low price, make it praiseworthily.
¨ Application
F2000IAQ-CO2 -3003D multiple controller is used to control CO2 level, temperature and humidity in order to offer right environment for plants growth or for foods storage.
It provides three dry contact outputs to control a carbon dioxide generator and a ventilator or other temperature/humidity equipments. It can provide RS485 communication with independent address to PC or other control systems.
It will be used below application:
Gas detected | Carbon Dioxide (CO2) |
Sensing element | Non-Dispersive Infrared Detector (NDIR) with more than 10 years lifetime |
Temperature sensor | NTC |
Humidity sensor | HS series capacitive sensor |
Temperature dependence | 0.2% FS/°C |
Temperature correction | Self compensation |
Power supply | 100VAC~240VAC or 24VAC, 50/60HZ±10%, selectable in order |
Consumption | 3.5 W max. ; 2.5 W avg. |
Accuracy@25°C(77°F) | ±40ppm + 3% of reading (0~5,000ppm) ±75ppm or 10% reading whichever is greater (0~20,000ppm) |
Stability | <2% of FS over life of sensor (15 yr typical) |
Calibration interval | ABC Logic Self Calibration Algorithm |
Non linearity | <1% of FS |
Pressure dependence | 0.13% of reading per mm Hg |
Altitude calibration | Programmable from 0-9,900m in 100m increments |
Response Time | <2 minutes for 90% step change |
Signal update | Every 2 seconds |
Warm up time | 24 hours (first time) 10 minutes (operation) |
CO2 measuring range | 0~5,000ppm 0~20,000ppm (optional) |
CO2 setting & Display resolution | 1ppm |
Temperature measuring range | -20~60°C(-4~140°F) |
Temperature setting range | 5~45°C(41~113°F) |
Humidity measuring range | 0~99%RH |
Humidity setting range | 5~95%RH |
Output resolution | 10Bit |
Relay output | Three ways dry contact outputs with programmable selection to control CO2,temperature,humidity Rated switching current: 2A(220VAC/30VDC), resistance load |
Communication interface | RS-485, 9600/14400/19200(default)/28800 or 38400bps (programmable selection), 15KV antistatic protection, 3 independent base address, max network node 64. |
Flow rates | 80 ~ 120 cc/min |
Operation conditions | 0~50°C(32~122°F); 0~95%RH, non condensing |
Storage conditions | 0~50°C(32~122°F); 0~90%RH |
Weight | 360g |
Dimensions | 130mm×90mm×40mm |
Installment standard | 65mm×65mm or 2”×4”wire box |
Wiring standard | Wire section area<1.5mm2 |
Approval Standard | CE-Approval |
Models
Model | Description |
F2000IAQ-CO2-3003D -(A)/(B)(C) | Special for green house and other agricultural fields. CO2& temperature& humidity detection to control CO2 generator and ventilation, photosensitive sensor detection to control CO2 generator day/night working mode. Power supply: (A): 200/240VAC (B): 100/120VAC (C): 24VAC |
F2000IAQ-CO2-5003D -(A)/(B)(C) | Special for green house and other agricultural fields. CO2&temperature&humidity detection to control CO2 generator and temperature & humidity devices, photosensitive sensor detection to control CO2 generator day/night working mode. RS485 communication interface. Power supply: (A): 200/240VAC (B): 100/120VAC (C): 24VAC |
Send Inquiry to This Supplier
You May Also Like
-
Qualified HST CS Series Iron Ore Carbon Sulfur AnalyzerNegotiableMOQ: 1
-
Supply of Electric Carbon Products Carbon and Sulfur Analyzer, Mingrui mr - Cs995 Type, High - Frequency Infrared Carbon and Sulfur AnalyzerUS$ 6123.08 - 6584.62MOQ: 1 Unit
-
Honeywell EZtrend® GR Advanced Graphic Recorder AgentNegotiableMOQ: 1 Unit
-
Lora Wireless CO2 SensorUS$ 165 - 180MOQ: 1 Piece
-
TOC Offline AnalyzerNegotiableMOQ: 1 Set
-
DI1500 Water Detection Industrial Laboratory TOC Analyzer Price Total Organic Analyzer MeterUS$ 10,000 - 15,000MOQ: 1 Piece
-
Online Technique Support Toc Analyzer With Good PriceUS$ 1,000 - 15,000MOQ: 1 Piece
-
CONTACT BLOCK FOR TEMPERATURE AND OXYGEN SENSORS-4(CORE)OXY&2(CORE)TEMP. USED IN MEASURING OXYGEN&TEMPERATURE ACTIVITY OF MOLTEN METALS IN TYPES B,R,S&IN MARK VII MODELS.NegotiableMOQ: 1 Piece
-
Non Destructive Testing Glass Miniature X Ray Tube With Tungsten FilamentNegotiableMOQ: 1 Piece
-
20X 40X Jewelry Gem Stereo Optical Microscope Parallel Microscopes A22.1207US$ $1 - $1MOQ: 1 Piece