Home > Products > Block Heater and Cooler > thermo block laboratory and cooler
thermo block laboratory and cooler
- 1000 Unit / Units per Month
- Guangzhou/Shenzhen
- T/T Credit Card PayPal
- Heat treatment vacuum furnace
- Atmopshere box furnace resistance furnace
- tube furnace facotry sale cheap price
- muffle furnace shanghai factory furnace box furnace
- MD series intelligent microwave digestion device for food industry heavy metal detection
- Laboratory high-purity nitric acid purifier ultra-pure hydrochloric acid purification system low-background hydrofluoric acid preparation system
Product Details
Brand Name: | A&E Lab | Model Number: | ABH-102 (CL2) | Place of Origin: | Guangdong, China |
Product Description
Specifications
thermo block laboratory and cooler1. Certificate: CE&ISO
2.Warranty: 1 year
3. Delivery time: Within 10 days
A & E Lab Hot Selling are include: UV VIS Spectrophotometer, Visible Spectrophotometer, PCR-Cycler, Blocker Heater,Shaker Incubator,Melting Point Device, Hotplate, Stirrer, Stirrer Hotplate, Rotory Mixer, Tube Roller Mixer, 3D Rocker, See-Saw Rocker, Vortex Mixer, Orbital Shaker, Electronic pipette and Block heater and cooler, etc.
Welcome to inquire us!
Block Heater and Cooler
Block heater and cooler (ABH CL series) are designed for widely use in Chemical, Biochemical, Clinical and other General Labs for storage, heating, digesting, incubating, concentrating and other heating and cooling processes, and due to the incorporating three stages temperature programming, it is much useful in enzymatic and other chemical catalytic reaction.
The (ABH CL series) are using Peltier to fulfil the heating and cooling process. It has the capacity to increase or decrease the block temperature to higher or lower than environmental temperature.
In addition, the cooling capacity helps the machine quickly ramp down the temperature to the lower temperature setting. This is greatly helping the temperature reaching equilibrium quickly.
The machine accommodates many different variety of blocks regardless the different block thickness, 25 mm, 35 mm, and 50 mm (for thicker blocks, it takes longer time to reach the equilibrium, or even very hard to reach the extreme temperature setting, such as 0 and 100 C). It is designed to be relatively independent on the environmental temperature. For example, if you set the temperature at 25 C, it becomes heating process when you operate the machine in the cold room (environmental temperature < 25 C), or cooling process when you operate the machine at environmental temperature > 25 C. It is same case as whether the block temperature is higher or lower than the setting point, the machine can always start the correct process and to reach the correct setting point.
These machine differs from PCR and other heating/cooling machines in which the thermistor is located inside the sample blocks (or plates). Even the dry block has similar configuration as the machine, the dry block can only use relatively identical block format (same block thickness) and use heating process only. Our unique control algorithm does not need any input from users, and can be operated in various cases: different block thickness, and different environmental status etc. It always can bring the block temperatureto the closer points of the setting temperature point.
Since it can work more flexible than other heating/cooling machines, it sacrifices that the accuracy of the block temperature at setting points (it could be varied in the range of +/- 5C). We need a good calibration method to do quick correction to reach the accurate point. The calibration must be easily to operate, and avoid the frequent calibration for the users.
In normal calibration method, the calibration step must be done before running the sample. It takes a longtime and could be time consuming process. Most importantly, the normal calibration methods (regardless multi-points calibration or change the value thru a potantiostat) change the system thermo-table value.It will greatly affect the performance of the machine and need to do very often calibration.
The new calibration in the machine is totally different from present method. There is no special calibrationstep in the machine. The calibration can only be done in the equilibrium stage during run. In the equilibrium stage, users enter the correct value, and the machine will start to run again to reach the new equilibrium point. At this time, the timing will be paused if running the timer, and will be resumed after reaching the new equilibrium. In the same time, the correct value will be stored in the memory as individual point. The system thermo table remains unchanged. In the next run, the machine will look up the memory to find the calibration value first, if it could not find, it will look back to the system table. The memory can store more than 70 points, and when the memories full, the new data will push out the oldest data out of memory.
It has a warning light, and it will be turned on when the machine temperature reaching above 50 C.
There are three major thickness of blocks:
1. The 50 mm thickness type of blocks, usually used for large volume and incubation or storage purpose. The maximum and the minimum block temperature can only reach 80 C and 10 C.
2. The 35 mm thickness type of blocks, usually used for medium volume (5 – 10 ml vials). It can reach the set temperature ranging from 0 - 100 C. However, it could take longer time to reach the equilibrium point.
3. The 25 mm thickness of type of blocks, usually used for smaller volume (up to 2 ml vials). It is designedto use in enzymatic, catalytic and other chemical reaction which required fast ramping rate reaction.
Technical Specification:
Model | ABH-101 (CL1) | ABH-102 (CL2) |
Temperature Range | 0 (< room temp - 25C) to 100 C | 0 (< room temp - 25C) to 100 C |
Control | PID | PID |
Max. Block Number | 1 | 2 |
Temperature Stability | ±0.1 C | ±0.1 C |
Temperature Maximum Variety between Identical Blocks @ 50 C | ±0.2 C | ±0.2 C |
Ramping time ( min) | 4 (from 0 - 100 C, without block); 10 (from 100 - 0 C, without block) | 4 (from 0 - 100 C, without block); 10 (from 100 - 0 C, without block) |
Timing (min) | 999 | 999 |
Programming | 3 stages temperature and timing | 3 stages temperature and timing |
Power Supply | 100V – 230V, 120 W | 100V – 230V, 240 W |
Dimension LXWXH(mm) | 210X260X150 (not include the sample chamber high 50 mm) | 260X260X150 (not include the sample chamber high 50 mm) |
Weight (KG) | 3.9 | 4.9 |
Contact Us
- A & E Lab Instruments (Guangzhou) Co., Ltd.
- Contact nameElla Wu
- Phone86-20-34216300
- Address#1708, 17F,New Century Plaza, No.2-6 Hongde Rd. Guangzhou,Guangdong
- Isotopic Ultrapure Laboratory Using PFA Acid Purification System Premium Pure Acid
- Hydrothermal synthesis reactor non-magnetic stainless steel outer tank PTFE or TFM inner vessel
- Graphite reactor is one of the direct, effective and economical sample pretreatment methods for elemental analysis.
- Fully automatic wet digestion platform Sample pretreatment Automatic graphite digestion instrument heating evenly
- Customized Temperature-controlled Electric Hot Plate Soil Sample Digester Heavy Metal Detection Digester
- Customized 350°C Graphite Electrical Heating Plate Without Teflon Coating Strong Corrosion Resistance
- Chemical and pharmaceutical hydrogen fluoride distillation condensing device Corrosion-resistant and high-temperature-resistant Teflon plastic distillation reaction device Flask with cooling jacket
- Atmosphere Furnace shanghai factory
- Tube Furnace Type GKD-TF
- muffle furnace shanghai Gaokeda furnace box furnace
- 1200C Vacuum crucible annealing furnace for semiconductor wafer
- Laboratory heat treatment equipment vertical quenching furnace
- 1400C Electric Heating Muffle Furnace
- HC-B070 medical devices for laboratory Stainless steel water Distiller Factory supply of laboratory 5L-20L (common)
- HC-B063 Low Price Laboratory equipment Industrial heating magnetic stirrer
- HC-B070A laboratory Stainless steel electric water Distiller 5L-20L (Automatic control)
- HC-B062 Cheap Laboratory Magnetic Stirrer With Hot Plates / Magnetic hot plate
- HC-B061 Factory price Stable temperature magnetic stirrer/Cheap plate magnetic stirrer
- HC-B064 Lab 100-5000ml capacity Stable temperature magnetic stirrer
- HC-B070 laboratory Stainless steel water Distiller 5L-20L (common)
- Carbon fiber Making Process High temperature Carbonization Furnace With 2000 Celsius
- Horizontal Style Electro-Thermostatic Blast Oven up to 250
- 250 Degree High Quality Electro-thermostatic Blast Laboratory Oven
- Laboratory High Quality Electro-thermostatic Blast Oven Up to 300 Degrees
Popular Searches
Recommended Products
- molecular sieve 5A zeolite adsorbent for PSA nitrogen separation
- 4A molecular sieves adsorbents for ethanol distallation and dehydration
- zeolite 5A molecular sieves desiccants for liquid coatings drying and dehydrating
- 13X molecular sieves adsorbents for nitrogen adsorption and hydrogen separation
- oxygen lithium molecular sieves adsorbents for nitrogen and oxygen separation
- Laptop Cooling Pads TIG780-18 Liquid Metal Thermal Conductive Paste Grease For CPU GPU Ultra
- Food Industry Grade CAS 13717-00-5 Magnesia MgCO3 Inorganic Chemicals
- Factory Supply choline chloride price per kg Feed Additive 60% choline chloride price
- Chemical Auxiliary Agent C6H11NaO7 Sodium Gluconate CAS 527-07-1
- CAS 13717-00-5 Magnesia MgCO3 China factory supply low price
- Dicalcium Phosphate 18% Feed Grade Powder CAS 7757-93-9 CaHPO4
- Hot Selling Tributyrin Powder CAS 60-01-5 tributyrin x
Find Similar Products By Category
- Chemicals > Lab Supplies > Laboratory Heating Equipments
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Ella Wu
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-