Smart series water purification system
Features and functions
- One time injection molding process case, material: Polypropylene PP.
- Elegant and compact case, integrating pre-filter, RO, DI, UV, UF and terminal filter into one.
- All filters are built-in, the smallest outside space.
- Top cap of pre-filters in the case can be rapidly opened to replace the pre-filters without opening the case.
- With electronic pressure sensor and microcomputer controlling, the system automatically produces pure water.
- RO membrane auto flushing,
- Automatic stop without water, automatic stop when water tank full, automatic cutting off water when pump stopping, guaranteeing 24 hours’ work.
- On-line resistivity monitor, with apheliotropic LCD display, monitor deionized water or ultrapure water’s quality real-timely.
- Attached portable TDS (total dissolved solid, ppm) test pen, with dry cell design, to monitor tap water and RO water’s quality.
- Pipeline with NSF authorization to assure high quality ultrapure water.
- New easy-inserting adaptor to make convenience of cartridge maintaining and replacing.
- Different tanks to meet every needs and assure ample water-supply.
- RO membrane, manufactured by DOW or CSM, to assure RO membrane’s long time and high quality of pure water.
- 4 ultrapure polishing resin cartridge with DOW’s polishing resin, to assure the top-level water quality of ultrapure water.
- Double wavelength(185&254 nm)UV lamp cartridge, to achieve effective sterilization and reduce TOC index.
- 5000 Doulton ultra-filtration cartridge, Manufactured in Germany, to eliminate endotoxin. Suitable for Cell cultivating and IVF.
- (0.45+0.1)µm PES terminal filter, to assure the quality absolutely axenic.
Smart series products
- RO lab/RO DI series reverse osmosis/deionized water system (Tap water inlet)
- Ultra series ultra pure water system (Tap water inlet)
- Research series ultra pure water system (pure water inlet)
Specification | RO system | RO deionized system | |||
Model | RO lab | RO lab plus | RO DI/RO DI digital | RO DI plus/RO DI digital plus | |
Flow procedure | PF+AC+RO+AC | PF+AC+RO+AC | PF+AC+RO+DI | PF+AC+RO+DI | |
Application | Ware washing, Agricultural expe, General biological expe, Aquatic products feeding, Inlet water for Ultra pure water machine, Inlet water for sterilizer/T&H chamber | Buffer disposing, Physical and chemical analysis, Fine chemistry industry, GC/HPLC, Inlet water for Ultra pure water machine, Aseptic drinking water | |||
Feed water requirement | Tap water: TDS<200ppm,5-45℃,1.0-4.0Kgf/cm2 (if inlet TDS>200ppm, extra pretreatment is recommended) | ||||
Purification system | Pretreatment unit | Special spun fiber filter×1+Special active carbon block filter×1+Special active carbon block filter×1 | |||
RO unit | 100GPD RO membrane×1 | 100GPD RO membrane×2 | 100GPD RO membrane×1 | 100GPD RO membrane×2 | |
Subsequent unit | Post active carbon filter×1 | Mixed bed resin cartridge×2 | Mixed bed resin cartridge×3 | ||
Pure water quality | Desalination rate% | >95% | >95% | ||
TDS | 5-10 ppm* | RO water:5-10 ppm* | |||
Resistivity | - | 15-18.2MΩ.cm | |||
Conductivity | - | 0.067-0.055µs/cm | |||
Output(25℃) | 15 liters/hour* | 30 liters/hour* | 15 liters/hour* | 30 liters/hour* | |
Flow rate | 2 liters/min(with pressure tank) | ||||
Pure water outlet | RO water | RO water, deionized water | |||
Control system | Automatic electronic pressure sensor controlling, RO membrane auto flushing, automatic stop without water, automatic stop when water tank full, automatic cutting off water when pump stopping, guaranteeing 24 hours’ work. | ||||
Water quality monitor | TDS test pen | TDS test pen +on-line resistivity monitor | |||
Electric requirements | AC110-220V,50/60Hz, 48W plus model:72W | ||||
Dimension and weight | Length×Width×Height:41×22×42cm / 12-14kg | ||||
Standard configuration | Main body(including:1 set cartridge)+4.0 gallon water tank + TDS pen + accessory box | ||||
- RO lab/RO DI series reverse osmosis/deionized water system (Tap water inlet)
- Feed water :TDS=200ppm, 25℃, 50psi and 15% recovery rate.
- GPD=gallon per day. 1gallon=3.78L.
- The quality of feed water will influence outlet water quality and cartridge’s life.
- PF: Pretreatment, AC: Active carbon, RO: Reverse osmosis, DI: Deionization.
Specification | Standard | Eliminating endotoxin | Low TOC | Comprehensive | |
Model | Ultra pure | Ultra pure UF | Ultra pure UV | Ultra pure UVF | |
Ultra pure plus | Ultra pure plus UF | Ultra pure plus UV | Ultra pure plus UVF | ||
Flow procedure | PF+AC+RO+DI+TF | PF+AC+RO+DI+UF+TF | PF+AC+RO+UV+DI+TF | PF+AC+RO+UV+DI+UF+TF | |
Application | Microanalysis Environmental analysis AA,ICP,IC Buffer disposing Pharmacy research Medicine examining, | Molecular biology PCR, gene research Pharmacy research Medicine examining, Cell cultivating IVF etc. | Micro organic analysis Environmental analysis HPLC,TOC VOC,GC/MS Pharmacy research Medicine examining, | Molecular biology Micro organic analysis Environmental analysis Pharmacy research Medicine examining Cell cultivating, IVF etc. | |
Feed water requirement | Tap water: TDS<200ppm,5-45℃,1.0-4.0Kgf/cm2 (if inlet TDS>200ppm, extra pretreatment is recommended) | ||||
Purification system | Pretreatment unit | Special spun fiber filter (“plus UF/UV/UVF” model: outside 10" spun fiber filter)×1+Special active carbon block filter×1+Special active carbon block filter×1 | |||
RO unit | 100GPD RO membrane×1 (“plus” model:2×100GPD RO membrane) | ||||
Subsequent unit | Ultrapure polishing resin cartridge× 4+(0.45+0.1)μm terminal filer×1 UV model:+Double wavelength(185&254)nm UV lamp cartridge×1 UF model:+5000 Doulton UF cartridge×1 UVF model:+Double wavelength(185&254)nm UV lamp cartridge×1+5000 Doulton UF cartridge×1 | ||||
Ultrapure water quality | Resistivity | 18.2MΩ.cm@25℃ | |||
Heavy metal ions | <0.1ppb | ||||
TOC | <10 ppb | <5 ppb | |||
Endotoxin | - | <0.001EU/ml | - | <0.001EU/ml | |
particle(>0.22μm) | <1/ml | ||||
Bacteria | < 1cfu/ml | ||||
RO water quality | < TDS(ppm, mg/l) of tap water×5% | ||||
Output(25℃) | 15 liters/hour* (“plus” model:30 liters/hour*) | ||||
Flow rate | 2 liters/min(with pressure tank)(Less output with UF/UV cartridge) | ||||
Pure water outlet | RO water ,ultrapure water | ||||
Control system | Automatic electronic pressure sensor controlling, RO membrane auto flushing, automatic stop without water, automatic stop when water tank full, automatic cutting off water when pump stopping, guaranteeing 24 hours’ work. | ||||
Water quality monitor | TDS test pen+ on-line resistivity monitor | ||||
Electric requirements | AC110-220V,50/60Hz, 48W/plus model:72W | ||||
Dimension and weight | Length×Width×Height:41×22×42cm / 12-14 kg | ||||
Standard configuration | Main body(including:1 set cartridge)+4.0 gallon water tank + TDS pen + accessory box | ||||









Send Inquiry to This Supplier
You May Also Like
-
Water Bath Vacuum Packaged Food Pasteurizer Machine/Tunnel Tomato Paste Pasteurization MachineNegotiableMOQ: 1
-
Electric Spray for Medical PlacesUS$ 13.5 - 14.5MOQ: 40 Pieces
-
Super Brake Fluid Oil In 250ml CanNegotiableMOQ: 1 Piece
-
Iphone Protective CaseNegotiableMOQ: 1 Piece
-
Optical Instrument Machining ComponentsNegotiableMOQ: 1 Piece
-
for Packaging Factory Drinking Water Srerilization Lamp uv Bottle Sterilizer With Low PriceUS$ 1,900 - 3,500MOQ: 1 Set
-
2017 Portable Medical Laboratory Clinic 18L 24L 30L Cheap Autoclave PriceNegotiableMOQ: 1 Set
-
Beiqi Salon Furniture Tool Sterilization CabinetNegotiableMOQ: 10 Pieces
-
Cheap Pet Hospital IncineratorUS$ 28,000 - 42,000MOQ: 1 Set
-
Hot Sale Sterilized BoilerUS$ 5.00 - 15.00MOQ: 1 Set