2015 Promotion!!!CE Approved 6-Parameter Patient Monitor /BP Monitor/ECG Monitor RPM-9000C2
Features:
High resolution 8.4”color TFT display
Lightweight, compact and portable
ECG, SPO2, NIBP, RESP, TEMP, PR
Bulit-in rechargeable lithium battery
ECG waveforms of 7-leads display on the same screen
72-hours graphic and tabular trends of all parameters
72 alarm events of all parameters recall
32 seconds full-disclosure waveform review
500 NIBP measurement date can be storage and recall
Date and waveforms color be adjustable
Arrhythmia analysis and S-T segment analysis
Suitable for adult,pediatric and neonatal patient
Audible and visual alarm, alarm events review
Can be used to monitor adult, pediatrics and neonate patients
a. Method: Oscillometry
b. Modes: Manual/Auto/Comtinuous
c. Auto measure time:Adjustable
d. Measurement rang:10-270mmHg
ECG:
a. Lead mode:3-lead or 5-lead
b. Lead selection:I;II;III;avR;avL;avF;V
c. Heart rate range:Adult:15-300bpm;
Pediatric/Neonatal:15-300bpm
d.ECG waveform: 2 channals
e. Accuracy: ± 1 bpm or ±1%
f. S-T segment detection Measurement rang :-0.2mv~2.0mv
g. Alarm:Yes,audible and visual alarm,alarm events review
h. High resolution 12.1"color TFT display
i. Lightweight,compact and portable
j. ECG,APO2,NIBP,RESP,2-TEMP,PR
k. Optional:2-IBP,ETCO2,And thermal printer
l. Bulit-in rechargeable lithium battery
m. ECG waveforms of 7-leads display on the same screen
n.72-hours graphic and tabular trends of all parameters
o. 72 alarm events of all parameters recall
p. 32 seconds full-disclosure waveform review
q. 500 NIBP measurement date can be storage and recall
r. Date and waveforms color be adjustable
s. Arrhythmia analysis and S-T segment analysis
t. Suitable for adult,pediatric and neonatal patient
SPO2
a. Measurement range:0-100%
b. Accyracy:70-100%, ±2% 0-69%,upspecified
Pulse rate
a. Range:20-254bpm
b. Accuracy: ±3bpm
Respiration
a. Method:RA-LL impedance
b. Range:Adult:0-120rpm;pediatric/neonatal:0-150rpm
c. Apnca alarmYes
Temperature
a. Range:0-50℃
b. Apnca: 0.1℃
c. Channal:Dual-Channal
Standard Configuration:
ECG/ NIBP /SPO2/ TEMP/ RESP /PR
Item |
No. |
Contents |
Qty |
Remark |
|
1 |
Main Unit |
1 |
|
|
2 |
Power cable |
1 |
|
|
3 |
NIBP tube |
1 |
|
|
4 |
ECG cable with Temp |
1 |
5 lead |
Standard Configuration |
5 |
ECG Electrodes |
12 pieces-1 pack |
adult |
|
6 |
SPO2 Sensor |
1 |
adult |
|
7 |
Cuff |
1 |
adult |
|
8 |
Packing list |
1 |
|
|
9 |
User Manual |
1 |
|
|
10 |
Temperature cable sensor |
1 |
|
Send Inquiry to This Supplier
You May Also Like
-
Hospital Infusion Syringe Pump Suitable for Different Brands of SyringesUS$ 230 - 450MOQ: 1 Piece
-
K4 GSM Elderly Care Monitoring Alarm SystemUS$ 1 - 10MOQ: 1 Piece
-
YSBB-100S Top Selling Mobile Infant Incubator Newborn Baby IncubatorNegotiableMOQ: 1 Set
-
Emergency Rescue Stretcher by LLDPE With Rotational Moulding for Military ArmyUS$ 100 - 200MOQ: 1
-
Multi-Function Electric Hospital Bed With LCD DisplayUS$ 1,500 - 5,000MOQ: 5 Sets
-
High Concentration Oxygen Source Medical Dental Ozone GeneratorUS$ 200 - 300MOQ: 1 Set
-
Discount KL001-4 Electric Hospital Care Bed Pediatric Hospital Bed Cheap Hospital BedUS$ 200 - 1,000MOQ: 1 Pack
-
Heart Model,biology ModelNegotiableMOQ: 100 Pieces
-
Ward Equipments Components of Wheel Chair PartsUS$ 6 - 15MOQ: 100 Pieces
-
Medical G03 Double-arm Orthopaedics Traction BedNegotiableMOQ: 1 Piece