DIN Rail Switching Power Supply DR-75-24
Specifications
Single Output Industrial DIN Rower supply DR-75-24 Switching powerCompact size,light weight
100%full-load burning test
DIN Rail switching power supply DR-75-24
| Model Specification |
DR-75-12 | DR-75-24 | DR-75-48 |
| DC output voltage | 12V | 24V | 48V |
| Output voltage error (Note2) | ±2% | ±1% | ±1% |
| Rated output current | 6.3A | 3.2A | 1.6A |
| Output current rage | 0-6.3A | 0-3.2A | 0-1.6A |
| Wave and noise(Note3) | 100mVp-p | 150mVp-p | 240mVp-p |
| Inlet stability(Note4) | ±0.5% | ±0.5% | ±0.5% |
| Load stability(Note5) | ±1% | ±1% | ±1% |
| DC output power | 75.6W | 76.8W | 76.8W |
| Efficiency | 76% | 80% | 81% |
| Adjustable range for DC voltage | 10.8-13.2V | 21.6-26.4V | 43.2-52.8V |
| AC input voltage range | 88~264 47~63HZ;248~370VDC | ||
| Input current | 1.8A/115V 0.90A/230V | ||
| AC lnrush current | Cold-start current 30A/115V 60A/230V | ||
| Leakage current | <3.5mA/240VAC | ||
| Overload protection | 105%~150% Type- PULSING HICCUP SHUTDOWN Reset. auto recovery |
||
| Over-voltage protection | 13.8-16.2V | 37.6-32.4V | 58-62V |
| High-temperature protection | |||
| Temperature coefficient | ±0.03%°C(0~50°C) | ||
| Setup rise hold up time | 1000ms,60ms,50ms/230VAC | ||
| Vibration | 10~500Hz,2G 10min./1cycle,Period for 60min,Each axes | ||
| Withstand voltage | Input and output interval- 1.5KVAC,Input and enclosure- 1.5KVAC,Output and enclosure-0.5KVAC |
||
| Isolation resistance | Input and output interval,Input and enclosure,Output and enclosure- 500VAC/100M Ohms | ||
| Working temperature and humidity | -10°C~+50°C,20%~90%RH | ||
| Store temperature and humidity | -20°C~+85°C,10%~95RH | ||
| Overall dimension | 55.5*125.2*100mm | ||
| Weight | 0.55Kgs 20PCS/14KG/1.1CUFT | ||
| Safety standards | Meet UL1012 | ||
| EMC standards | Meet Part 15J conduction class B | ||
| Note:1.The testing condition for the parameter above is:230VAC input, rated load,25°C 70%Rh,Humidity 2.Error,include the setting error, line stability and load stability.(Note:5) 3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting 4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage. 5.Load stability test: The load is from 0% to 100%,others 60%. 6.C2311must be knocked down. | |||
Send Inquiry to This Supplier
You May Also Like
-
SPS5710 51199929-100 Honeywell Power Supply ModuleNegotiableMOQ: 1 Piece
-
ANDW Series Pure Sine Wave InverterNegotiableMOQ: 1 Set
-
Industrial Grade LED Power Supply for Long Strip LED LightNegotiableMOQ: 100 Pieces
-
Switching Power SupplyNegotiableMOQ: 2700 Pieces
-
Scrap Recycle Computer Hardware Untested Computer Power SuppliesNegotiableMOQ: 10000 Pieces
-
CX-9001 1KVA Knob Type Variable AC Power Supply Unit of Single Phase Input and Single Phase OutputNegotiableMOQ: 1 Piece
-
Universal Travel Adapter&power Power Converter Adapter Power SupplyUS$ 100 - 5,000MOQ: 10 Sets
-
Hot Sales 5050 Smd Led Strip Power SupplyUS$ 0.78 - 1.5MOQ: 1000 Poles
-
(DC Power Supply) QJ12003E 100% Original&New!!NegotiableMOQ: 1 Set
-
TS-001 Mini Circuit Breaker 12V Power Supply Din Rail ChannelNegotiableMOQ: 100 Pieces