Home > Instruments & Meters > Electronic Instrument > Oscilloscope > DSO1202E,Handheld Hantek Oscilloscope,200MHz Bandwidth

DSO1202E,Handheld Hantek Oscilloscope,200MHz Bandwidth

DSO1202E,Handheld Hantek Oscilloscope,200MHz Bandwidth photo-1
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Place of Origin:
Fujian, China
Model Number:
DSO1202E
Payment & Shipping
Payment Methods:
Port of Shipment:
xiamen shenzhen
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Fujian, China
Model Number DSO1202E

Specifications

DSO1202E,200MHz Handheld Hantek Oscilloscope
1GS/s sample rate,6000 Counts DMM with analog bargraph
2M Memory Depth

 

Function & Benefits
  • Five in one: Oscilloscope/Recorder/DMM/FFT Spectrum Analyzer/Frequency Counter
  • 200MHz Bandwidth, 1GS/s sample rate,6000 Counts DMM with analog bargraph
  • 5.6 inch TFT LCD Display,640*480; Dual-Window Design for more detailed
  • Easy-to-use pop-up menu with built-in multi-language help system
  • 2M Memory Depth and 32 Automatic Measurements
  • Automatic cursor tracking measurements
  • Average Mode for smoothing waveforms
  • USB Host/Device 2.0 full-speed interface; support removeable disk;LAN Option, easy to control by PC or long-distance
Specifications

 

Model DSO1072E DSO1102E DSO1152E DSO1202E
Sample Modes Real-Time Sample
Normal Normal data only
Peak Detect High-frequency and randon glith capture
Average Wavefom Average, selectable 4,8,16,32,64,128
Inputs Coupling AC, DC, GND
Inputs Impendance 1MΩ±2% ll20pF±3pF
Probe Attenuation 1X, 10X
Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X
Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×)
Horizontal System
Sample Rate Range 1GS/s
Waveform Interpolation (sin x)/x
Record Length 2M
SEC/DIV Range 4ns/div~2000s/div, in a  2, 4, 8 sequence 2ns/div~2000s/div, in a  2, 4, 8 sequence
Sample Rate and Delay Time Accuracy ±50ppm over any ≥1ms time interval
Scanning Speed Range 4ns/div to 8ns/div; (-8div x s/div) to 40ms;
20ns/div to 80μs/div;(-8div×s/div) to 40ms
200μs/div to 40s/div; (-8div×s/div) to 400s
2ns/div to10ns/div;
 (-4div×s/div) to 20ms;
Delta Time Measurement Accuracy 
(Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);Sample interval = s/div ÷ 200
Vertical System
Vertical Resolution 8-bit resolution, all channel sampled simultaneously
Volts Range 2mV/div to 100V/div at input BNC
Bandwidth 70MHz 100MHz 150MHz 200MHz
Rise Time at BNC( typical) 5ns 3.5ns 2.3ns 1.8ns
Analog Bandwidth in Normal and Average
modes at BNC or with probe, DC Coupled
±400V(100V/div-20V/div);  ±50V(10V/div-5V/div); ±40V(2V/div-500mV/div); 
±2V(200mV/div-50mV/div); ±400mV(20mV/div-2mV/div)
Math +, -, *, /, FFT
FFT Windows:Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point
Bandwidth Limit 20MHz
Low Frequency Response (-3db) ≤10Hz at BNC
Trigger System
Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source CH1, CH2, AC Line
Trigger Modes Auto, Normal, Single
Coupling Type DC, AC, HF Reject, LF Reject, Noise Reject
Trigger Sensitivity DC(CH1,CH2): AC; HF Reject; LF Reject
Trigger Level Range CH1/CH2: ±8 divisions from center of screen; 
Video Trigger
Video Trigger Type CH1, CH2: Peak-to-peak amplitude of 2 divisions;
Signal Formats and Field Rates Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range 100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range 20ns ~ 10s
Slope Trigger
Slope Trigger Mode Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range 20ns ~ 10s
Overtime Trigger
Over Time Modee Rising edge or Falling edge
Time Range 20ns ~ 10s
Alternative Trigger
Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution 6 digits
Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range AC coupled, from 4Hz minimum to rated bandwidth
Signal Source Pulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor Measurement Manual: Voltage difference between cursors: deltaV
Time difference between cursors: deltaT
Reciprocal of deltaT in Hertz (1/deltaT);
Tracing: The valtage and time at a waveform point;
Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS,
Scope Trendplot 1.2M Point
General Specifications
Display Resolution 640 horizontal by 480 vertical pixels
Display Contrast Adjustable (16 gears) with the progress bar
Frequency(typical) 1kHz
Dimension 260mmmm; 220mm; 75mm
Weight 2.5KG(without Packing)