Braided Power Cable
Specifications
Braided power cableCopper/AL cable
High voltage/Medium voltage cable/Low voltage cable
Control cable/power cable
Braided power cable
1-Conductor: Solid or stranded copper or AL
2-Insulation: XLPE or PVC or Rubber
3-Circuit Identication: The insulation shall be red, yellow, green, black, yellow/green
4-Filler: Polypropylene lament with lapped binding tape
5-Inner Sheath: Polyvinyl chloride (Black)
6-Armor: Galvanized steel wire/steel tape/Unarmored
7-Core-covering: Binding tape
8-Outer Sheath: Polyvinyl chloride (Black)
9-Application: For use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time.
10-Standards / Testing Specications: IEC 60502-1.
11-Installation: This cable can be installed in duct, tray or direct burial. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.
XLPE Insulation Power Cable
12-The Application of Power Cable: Power Cable is used to transmit power on power distribution circuit of AC 50Hz, rated voltage 35 KV or lower. It has not only excellent electrical performance, mechanical performance, heat-resistant & anti-aging performance, environment resistant character & chemical-corrosion resistant performance, but simple structure, light weight, without restriction by laying fall, and it also has high temperature (90) for long term.
13-Instruction:
I. Executive Standard: GB12706.1.3 adopts international electrician committee IEC60502
II. Working Features:
1. Environment temperature should be no lower than 0 for laying, the cable fall without limitation
2. The min bending radius of cable is stipulated as follows: Single core: 20(d+D) 5% three cores: 15(d+D) 5% (D is actual diameter of cable; D is actual outer diameter of conductor).
3. Operation temperature of cable PVC sheath is no more than 90.
4. Max rated temperature of cable conductor is 90, and no higher than 250 in time of short circuit (max. Lasting time is no longer than 5s).
Our company can produce both flame retardant and non-flame retardant series of XLPE power cable...Our products can be produced according to our works specifications which are equivalent to GB12706, IEC60502, IEC60332, IEC60754, and its some indexes are superior to standards stated above...
The flame-retardant cable covers all kinds of low-smoke low-halogen, low-smoke halogen free and three classes of A, B, C. We can design and manufacture special XLPE cable according to the other standards require by the customers, such as heavy section cut part conductors, water-resistant, defend termites, defend mouse, and so on...
Send Inquiry to This Supplier
You May Also Like
-
Sick YF8U14-050VA3XLEAX - Sensor/actuator CableNegotiableMOQ: 1 Piece
-
Pesticide Spraying Machine Wire Harnrss Tractors and Agricultural Machinery Cable AssemblyNegotiableMOQ: 1 Unit
-
4/8/16/32CH Channels Multi Cable With Wheel/6 UTP Multipair CableUS$ 500 - 800MOQ: 10 Pieces
-
Bulk Electrical Wire Low EccentricityUS$ 1 - 10000MOQ: 1 Piece
-
Competitive Price LMR400 Coaxial CableNegotiableMOQ: 10 Kilometers
-
Energy Saving High Temperature Self-Regulating Heat Trace Cable for Industrial ApplicationsUS$ 1.4 - 2.4MOQ: 1 Meter
-
Fireproof CableNegotiableMOQ: 500 Meters
-
Hot Sale Magnet Polyesterimide Flat Enamelled Super Aluminum WireUS$ 4.89MOQ: 500 Kilograms
-
Advanced Self-Regulating Heating Cable for Freeze Protection & Temperature MaintenanceUS$ 0.98MOQ: 10 Meters
-
Sports and Gym Equipment Silicone Grip Pipe Wrapping TapeNegotiableMOQ: 1 Roll