Home > Products > Switches & Trucks Maching Swichgears > Combined Unit Using in Switchgears 12kV CT and VT
Combined Unit Using in Switchgears 12kV CT and VT
- 200 Unit / Units per Month
- Guangzhou Huangpu Port
- T/T Credit Card PayPal
Product Details
Place of Origin: | Guangdong, China | Brand Name: | Sihu | Model Number: | JCII (III) -12/150(210) - 650(800) |
Usage: | Power | Phase: | Single | Coil Structure: | Toroidal |
Coil Number: | Other, One or more |
Product Description
Combined Unit Using in Switchgears 12kV CT and VT
1. Application
The truck is mid-set mounted in the switchgears. It is composed of a primary terminal extending current transformer and a voltage transformer fuse enclosed. Our trucks are one type of patent products in our company.
2. General Technical Parameters
1).System Nominal Voltage: up to 12kV
2).Rated Operating Voltage: up to 10kV
3).Rated Frequency: 50Hz
4).Rated Primary Current: up to 1600 A
5).Rated Secondary Current: 5A
6).Rated Secondary Voltage: 0.1kV
7).Accuracy class up to 0.2 for metering; up to 10P for protection
*Except for the technical data listed above, we can design as per clients’ requirements.
3. Main Features
1).Excellent in insulation performance
2).Low partial discharge, high accuracy
3).With compact and reasonable structure
4).Enabling the structure of switchgear much more compact
5).Be able to improve the electrical and mechanical performance of the switchgears
6).High resistance to uncleanness and moisture
7).Epoxy resin insulated
4. Production Capability: 10,000 pieces per year
5. Minimum Order: 1piece
6. Delivery Time: 4-15 days
7. Manufacturing Standards: GB1207-2006, GB1208-2006, Q/SH005-2004
ABB Excellent Supplier
Our company is one of the excellent suppliers for high voltage products business unit of China.
Certificate of Measurement system
Our company has satisfied the requirements of Measurement Assurance System standards.
GOST Certificate
Our products had gained the GOST certificate and can enter the Russia market.
CE Certificates for current transformers
Combined Unit Using in Switchgears 12kV CT and VT
All our goods are packed in wooden cases, with foam inside for protection. And we have a team who is in charge of packing. The team consists of our skilful carpenters and experienced packing designers. These enable our packing reasonable, safe and reliable.
Combined Unit Using in Switchgears 12kV CT and VT
9.Technical Parameters for JCII (III) -12/150(210) - 650(800) Metering Trucks see Table 1~3
Table 1 Main Technical Parameters of CT LZZC3-12Q
Rated Primary Current (A) | Accuracy Class Combination | Rated Output at Relative Accuracy Class Combination cosΦ=0.8(lag) (VA) | Rated Short-time Thermal Current (r.m.s) (kA) | Rated Dynamic Current (Peak) (kA) | ||
Cl. 0.2S |
Cl. 0.5
| Cl. 10P10 | ||||
20~200 | 0.2S/10P 0.5/10P | 15 | 15 | 15 | 7.2~35 | 18~75 |
315~1250 | 55 | 137 | ||||
1500~1600 | 63 | 157.5 |
Table 2 Technical Parameters of VTs Table 3 Technical Parameters of Fuse
Model | Rated Voltage (kV) | Rated Voltage of Residual Voltage Winding (kV) | Rated Output (VA) | Limit Output (VA) |
| Model | Rated Voltage (kV) | Rated Current (A) | Breaking Ability (kA) | |||
Primary | Secondary | Cl. 0.2 | Cl. 0.5 | Cl. 1 | XRNP1-3.6 | 3.6 | 0.3 0.5 1 2 3 | 50 | ||||
JDZ19-10RJC (JDZ19-10RVJC) | 10 | 0.1 |
| 15 | 30 | 60 | 350 | XRNP1-7.2 | 7.2 | |||
JDZX19-10RJCI,II or III | 10/√3 | 0.1/√3 | 0.1/3 | 15 | 30 | 60 | 350 | XRNP1-12 | 12 |
10.For residual voltage winding: Accuracy class is 6P, rated output is 50VA.
11.Notes: Other technical data and outline drawing should be provided under request.
Combined Unit Using in Switchgears 12kV CT and VT
Combined Unit Using in Switchgears 12kV CT and VT
Combined Unit Using in Switchgears 12kV CT and VT
Contact Us
- Guangdong Sihui Instrument Transformer Works Co., Ltd.
- Contact nameLizhen Zhang
- Phone86-758-3233633
- AddressNo.8 Fuhua road, Dongcheng Street, Sihui City Zhaoqing,Guangdong
Combined Transformers | Current Transformers | Electric Insulation Articles | New Products |
Power Transformers & Reactors | Switches & Trucks Maching Swichgears |
- Acrel leakage current transformer rated current 400-800A Applied to residual current signal collection AKH-0.66/L L-150
- Acrel measuring rated current 250-400A low voltage leakeage CT Residual current transformer AKH-0.66/L L-100
- Acrel Applied to residual current signal collection residual current transformer AKH-0.66/L L-200 rated current 800-1500A
- Acrel AKH-0.66/L L-80 rated current 100-250A Applied to residual current signal collection measurement current transformer
- Acrel leakage current transformer rated current 400-800A Applied to residual current signal collection AKH-0.66/L L-150
- Acrelrated current 800-1500A Applied to residual current signal collection residual current transformer AKH-0.66/L L-200
- Acrel AKH-0.66/L L-45 residual current transformer rated current 16-100A Applied to residual current signal collection
- Acrel Can be widely used in industrial automation fields smart AC current transformer BA20(II)-AI/V
- Acrel smart AC electrical transducer BA50(II)-AI/V Mainly detects the leakage current of the electrical system
- Acrel BA50L(II)-AI/V smart AC electrical current sensor Can be widely used in industrial automation fields out 1-5V/0-5V
- Acrel BA50L(II)-AI/V Can be widely used in industrial automation fields out 1-5V/0-5V smart AC electrical current sensor
- Made in China Three phase dry type transformer SG-100VA for thermal power plant
- Flyback transformer
- Lan transformer
- НЕФТЯНОЕ МЕСТОРОЖДЕНИЕ SHENGDONG SHENGLI газогенератор мощностью 500 кВт T12V190
- shengdong shengli oil field 500KW natural gas generator T12V190ZL
- B6190 G6190 200KW diesel engine used in ship boat spare parts
- B12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- BH12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- AL12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- BL12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600lw
- Acrel smart AC electrical current sensor BA50L(II)-AI/V Can be widely used in industrial automation fields out 1-5V/0-5V
- Acrel BA50L(II)-AI/I AC current sensor in AC0-(0.1-1)A out 4-20mA/0-20mA Real-time monitoring of AC current in the power grid
- Acrel BA50(II)-AI/V AC electrical transducer Mainly detects the leakage current of the electrical system
Popular Searches
- power transformer
- Distribution Service
- current transformer
- power transformers
- High Frequency Transformer
- Electrical Transformer
- energy saver device
- led transformers
- step up converter
- Ac Drive Converter
- Frequency Drive Converter
- electronic transformer
- Lighting Transformers
- toroidal transformer
- auto transformer
- voltage transformer
Recommended Products
- FOXBORO FBMSVH Control card module
- FOXBORO FBMSVL Multi port serial card
- ABB XVC770BE102 3BHE021083R0102 Thermal dispersion technology flow meter
- ABB XVC770AE 3BHE006414R0001 Servo Driver
- ABB PFEA113-65 3BSE050092R65 Dual expansion port module
- ABB LTC391AE01 HIEE401782R0001 connecting module
- ABB DSAI 130A 3BSE018292R1 Digital input/output module
- GE SR489-P5-HI-A20-E Protection Relay
- VIBRO-METER VM600 RPS6U 200-582-500-013 Vibration monitoring and control system
- HONEYWELL SPS5710 51199929-100 Power supply module
- GE IS210BPPBH2CAA Digital expansion module
- GE IS200TSVCH2AED MRP246517 Digital I/O module
Find Similar Products By Category
- Electrical Equipment & Supplies > Transformers
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Lizhen Zhang
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-