Home > Products > Combined Transformers > PT Lightning Protection Combined Transformer Truck Use For Switchgear
PT Lightning Protection Combined Transformer Truck Use For Switchgear
- 10000 Unit / Units per Month
- Guangzhou Huangpu Port
- T/T Credit Card
Product Details
Place of Origin: | Guangdong, China | Brand Name: | SIHU | Model Number: | JCII (III) -12/150(210) - 650(800) |
Usage: | Power | Phase: | Single | Coil Structure: | Toroidal |
Coil Number: | Other, Optional |
Product Description
PT Lightning Protection Combined Transformer Truck Use For Switchgear
1. Technical Parameters
1).System Nominal Voltage: up to 12kV
2).Rated Operating Voltage: up to 10kV
3).Rated Frequency: 50Hz
4).Rated Primary Current: up to 1600 A
5).Rated Secondary Current: 5A
6).Rated Secondary Voltage: 0.1kV
7).Accuracy class up to 0.2 for metering; up to 10P for protection
*Except for the technical data listed above, we can design as per clients’ requirements.
2.Technical Parameters for JCII (III) -12/150(210) - 650(800) - Arrester Trucks see Table 1~4
Table 1 Main Technical Parameters of CT LZZC3-12Q
Rated Primary Current (A) | Accuracy Class Combination | Rated Output at Relative Accuracy Class Combination cosΦ=0.8(lag) (VA) | Rated Short-time Thermal Current (r.m.s) (kA) | Rated Dynamic Current (Peak) (kA) | ||
Cl. 0.2S |
Cl. 0.5
| Cl. 10P10 | ||||
20~200 | 0.2S/10P 0.5/10P | 15 | 15 | 15 | 7.2~35 | 18~75 |
315~1250 | 55 | 137 | ||||
1500~1600 | 63 | 157.5 |
Table 2 Technical Parameters of VTs Table 3 Technical Parameters of Fuse
Model | Rated Voltage (kV) | Rated Voltage of Residual Voltage Winding (kV) | Rated Output (VA) | Limit Output (VA) |
| Model | Rated Voltage (kV) | Rated Current (A) | Breaking Ability (kA) | |||
Primary | Secondary | Cl. 0.2 | Cl. 0.5 | Cl. 1 | XRNP1-3.6 | 3.6 | 0.3 0.5 1 2 3 | 50 | ||||
JDZ19-10RJC (JDZ19-10RVJC) | 10 | 0.1 |
| 15 | 30 | 60 | 350 | XRNP1-7.2 | 7.2 | |||
JDZX19-10RJCI,II or III | 10/√3 | 0.1/√3 | 0.1/3 | 15 | 30 | 60 | 350 | XRNP1-12 | 12 |
PT Lightning Protection Combined Transformer Truck Use For Switchgear : | |
For the low voltage products: | 5 -10 days |
For the medium voltage products: | 10 -15 days |
For the high voltage products: | 20 -30 days |
Payment: | T/T or L/C |
Port: | Guangzhou |
Packing: | Wooden case |
PT Lightning Protection Combined Transformer Truck Use For Switchgear :
- Your inquiry related to our product & price will be replied within 24hours
- Well-trained & experienced staff are to answer all your inquiries in English of course.
- Working time: 8:00am ~17:45pm, Monday to Saturday. (UTC+8).
- Provide perfect after-sale service, if you got any question, please contact with us and we wll solve your problem immediately.
- We have our own transportation department, goods can be delivered on time whenever they are ready.
- Your business relationship with us will be confidential to any third party.
1. Q: Minimum order quanlity?
A: 3units
2. Q: Delivery time?
A: 5~30 days (after order)
3. Q: Payment term?
A: L/C or T/T
4. Q: Tell me more about the product information.
A: Voltage Transformers&Current Transformers: up to 1000kV
Dry-type Power Transformers: up to 35kV
Switches: up to 35kV
Trucks Matching Switchgears: up to 35kV
Sensors: up to 35kV
Insulating Articles: up to 1000kV
Or you could send more the parameters of the product you need that help us to select suitable one for you.
Guangdong Sihui Instrument Transformer Works Co., Ltd. who lies in Sihui city, the mid-west of Guangdong Province, 63km away from Guangzhou. It was founded in 1988 and has become one of the top 5 instrument transformers enterprises in China.
A series of products, such as instrument transformers, power transformers, metering trucks, insulation articles and so on, have been professionally designed, manufactured and sold. All of them are suitable for the switchgears matching, power plants and substations in those systems of electric, railway and petrochemical industry. A great of products have owned proprietary intellectual property rights and core technology. Meanwhile, about 30 national honors have been won.
Our products have been sold well everywhere domestically as well as exported to Europe, America, Russia and Asia, which brings high reputation both at home and abroad. What's more, they are extraordinarily applied to power-supply systems of national key infrastructures, such as Guangzhou Baiyun International Airport, Guangzhou Metro, Shanghai Pudong Airport, Zhongnanhai, Beijing Olympic Game Venues, Jiuquan Satellite Shoot Centre, etc.
Contact Us
- Guangdong Sihui Instrument Transformer Works Co., Ltd.
- Contact nameLizhen Zhang
- Phone86-758-3233633
- AddressNo.8 Fuhua road, Dongcheng Street, Sihui City Zhaoqing,Guangdong
Combined Transformers | Current Transformers | Electric Insulation Articles | New Products |
Power Transformers & Reactors | Switches & Trucks Maching Swichgears |
- Acrel leakage current transformer rated current 400-800A Applied to residual current signal collection AKH-0.66/L L-150
- Acrel measuring rated current 250-400A low voltage leakeage CT Residual current transformer AKH-0.66/L L-100
- Acrel Applied to residual current signal collection residual current transformer AKH-0.66/L L-200 rated current 800-1500A
- Acrel AKH-0.66/L L-80 rated current 100-250A Applied to residual current signal collection measurement current transformer
- Acrel leakage current transformer rated current 400-800A Applied to residual current signal collection AKH-0.66/L L-150
- Acrelrated current 800-1500A Applied to residual current signal collection residual current transformer AKH-0.66/L L-200
- Acrel AKH-0.66/L L-45 residual current transformer rated current 16-100A Applied to residual current signal collection
- Acrel Can be widely used in industrial automation fields smart AC current transformer BA20(II)-AI/V
- Acrel smart AC electrical transducer BA50(II)-AI/V Mainly detects the leakage current of the electrical system
- Acrel BA50L(II)-AI/V smart AC electrical current sensor Can be widely used in industrial automation fields out 1-5V/0-5V
- Acrel BA50L(II)-AI/V Can be widely used in industrial automation fields out 1-5V/0-5V smart AC electrical current sensor
- Made in China Three phase dry type transformer SG-100VA for thermal power plant
- Flyback transformer
- Lan transformer
- НЕФТЯНОЕ МЕСТОРОЖДЕНИЕ SHENGDONG SHENGLI газогенератор мощностью 500 кВт T12V190
- shengdong shengli oil field 500KW natural gas generator T12V190ZL
- B6190 G6190 200KW diesel engine used in ship boat spare parts
- B12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- BH12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- AL12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- BL12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600lw
- Acrel smart AC electrical current sensor BA50L(II)-AI/V Can be widely used in industrial automation fields out 1-5V/0-5V
- Acrel BA50L(II)-AI/I AC current sensor in AC0-(0.1-1)A out 4-20mA/0-20mA Real-time monitoring of AC current in the power grid
- Acrel BA50(II)-AI/V AC electrical transducer Mainly detects the leakage current of the electrical system
Popular Searches
- power transformer
- Distribution Service
- current transformer
- power transformers
- High Frequency Transformer
- Electrical Transformer
- energy saver device
- led transformers
- step up converter
- Ac Drive Converter
- Frequency Drive Converter
- electronic transformer
- Lighting Transformers
- toroidal transformer
- auto transformer
- voltage transformer
Recommended Products
- TRICONEX 3009 Enhanced Main Processor (UMP) module Improve processor performance
- IS215ACLEH1BB Microprocessor-based controller
- 1394C-SJT22-A Servo controller Dc high precision power supply
- DS200TCQCG1BGF Dual system monitoring module
- CAT Caterpillar Starting Diesel Engine Battery 153-5720/12V210AH Maintenance-free
- IS215UCVEH2AE Used as a VME control card Vertical pin connector
- TRAFOTEK CHK0520 Line output reactor Reduce harmonic interference and improve system stability
- German CAT Carter Battery 115-2422 Deep Cycle Discharge 12V90AH Ship Starting Battery Excavator
- IC697CPX935 Central processing unit For communication
- 5464-414 Digital speed sensor A loop that provides control signals
- IC698CPE040-JP Central processing unit Rated processor speed
- A06B-6120-H075 driver The maintainability of the equipment is improved
Find Similar Products By Category
- Electrical Equipment & Supplies > Transformers
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Lizhen Zhang
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-