Place of Origin: | Guangdong, China | Brand Name: | NAPUI | Model Number: | NAPUI130D |
Usage: | Industrial | Theory: | Temperature Recorder | Accuracy: | ±0.2% |
Temperature Range: | -100~1370℃ |
Product Description
China NAPUI130T paperless chart recorder with security functions
1.10.2 inch (1024 X 600) TFT LCD high-brightness, clear picture, wide viewing angles.
2.Four wire resistive touch screen (4096 X 4096), and it provides swipe, pinch in/out, and click and drag controls for fast navigation of common display mode functions.
3.Powerful image display and data processing function.
4.Hidden embedded portable shape brings more convenience.
5.Support USB interface and large capacity. Effective support long-term information collection.
6.Powerful PC analysis software.
7.Data acquisition, monitoring, recording and controlling (including voltage, current, temperature, humidity, pressure, vibration, frequency, flow, liquid level, etc)
Specification:
AC/DC Power | 85VAV~265VA/24VDC±10% |
Power Waste | ≤25VA(The instrument input channel number affects actual power waste) |
Channel Number | 1-64 |
Input Signals | Thermocouple:K,E,R,B,N,T,E.J,S,WRE5-26,WRE3-25 |
Hot resistance:Pt100,Cu50 | |
Current:4-20mA,0-10mA,0-20mA | |
Voltage:0-5V,0-10V,1-5V | |
Measurement accuracy | ≤±0.2%F.S |
Recording rates | 1-19999s |
Recording capacity(Reference:68M) | 6 Days(64 channels; inter-record gap:1s) |
36 Days(64 channels; inter-record gap:1m) | |
Recording model | loop record |
Alarm type | free to set upper and lower limits for each channel alarm;4 alarms each channel |
Relay | TP1718 |
Distribution | 24VDC each channel |
Communications | Standard RS232C (or RS484, USB, Ethernet, GPRS wireless communications, etc.) |
Standard ModBus RTU communication protocol | |
Operating temperature | 0℃~50℃ |
Operating humidity | <85%R.H |
Storage temperature | -20℃~70℃ |
Storage humidity | <95%R.H |
Materials | ABS |
Dimensions | 288*288*200mm |
Panel cutout | 278*278mm |
Weight | 3.8KG |
Input Module:
TP1708 Input Mode | Input Type | Measuring Range |
Hot resistance | Pt100 | -200.0~650.0℃ |
Cu50 | -50.0~150.0℃ | |
Thermocouple | S | 500~1750℃ |
R | 500~1750℃ | |
B | 500~1800℃ | |
K | -50.0~1370℃ | |
N | 0~1300℃ | |
E | 0~1300℃ | |
J | 0~760℃ | |
T | -100~400℃ | |
WRE5-26 | 0~2300℃ | |
WRE3-25 | 0~2300℃ | |
Voltage | 0-10V | 0.000V~10.000V |
0-5V | 0.000V~5.000V | |
0-1V | 0.000V~1.0000V | |
±500mV | -500.0mV~+500.00mV | |
±100mV | -110.00mV~+110.00mV | |
1-5V | 1.000V~+5.000V | |
Current | 4-20mA | 4.00mA~+20.00mA |
0-20mA | 0.00mA~20.00mA | |
0-10mA | 0.00mA~10.00mA | |
Resistance | 100Ω | 0~100Ω |
TP1728 Input Type | 4 channel for temperature/humidity; TP2300 Digital signal for temperature/humidity. | temperature/humidity: -20~125℃/5%~95% |
Dispatch is arranged within 1-3days once your payment is finished verification by our Financial department. If there is no option of express you need. Pls contact us in advance.
The delivery time show when you choice the express is for reference. We don't guarantee the time the same with it all the time, due to difference in customs clearing times in individual countries, which may affect how quickly your product is inspected.
Buyer are responsible for all import fees. We can declare low value in Commerical invoice if you appoint.
Dongguan NAPUI Electronic Technology Co., Ltd is 8 years specialist digital power meter Manufacturer in China.
All the power meter waranty are 12 months.
All the items are EXW.
Contact Us
- Dongguan Napui Electronic Technology Co., Ltd.
- Contact nameCarina Wang
- Phone86-0769-22891717
- AddressPlant, 3rd Floor, Building 13, Small And Medium-Sized Enterprise Innovation Park, Northern Industrial City, High-New Technology Development Zone, Songshan Lake
- USA original BENTLY 3500/44-01-00
- Carel refrigeration thermostat PJEZY0H000 cold storage controller
- Carel refrigeration thermostat PJEZS2P010 cold storage controller
- Carel refrigeration thermostat PJEZS0H000 cold storage controller
- Carel refrigeration thermostat PJEZS00000 cold storage controller
- Carel refrigeration thermostat PJEZC0P000 cold storage controller
- Carel refrigeration thermostat PJEZC0H000 cold storage controller
- Carel refrigeration thermostat PJEZC00000 cold storage controller
- Carel multi-parallel refrigerator controller MX30M25H00 temperature controller MPX PRO
- 698 photovoltaic protocol converter photovoltaic inverter power generation electricity consumption information collection
- New York Inspiration Temperature Sensor, Model 025W39721-302
- Repair of the exhaust temperature probe of the new York temperature sensor 639A0151H01 compressor condensing unit
- USA original bently nevada 330171-00-08-10-02-00 330173-00-05-10-12-00 330172-16-42-10-01-00
- USA original bently nevada 330130-040-00-00 330130-085-00-05
- USA original bently nevada 330106-05-30-10-02-00 330106-05-30-15-02-CN 330130-035-00-CN
- USA original bently nevada 330104-00-04-10-02-00 330103-11-19-10-02-00 330106-05-30-05-02-CN
- USA original bently nevada 330104-00-04-10-02-CN
- USA original bently nevada 330104-00-03-05-02-00
- USA original bently nevada 330103-12-25-10-01-00 330103-13-23-05-02-00 330103-15-23-05-02-CN
- USA original bently nevada 330103-05-15-05-02-00 330103-05-13-10-02-00 330103-10-20-05-02-CN
- USA original bently nevada 330103-02-12-05-02-CN 330103-03-12-05-02-00 330103-05-10-10-02-05
- USA original bently nevada 330103-00-20-10-02-00 330103-01-07-05-02-00 330103-02-07-10-02-00
- USA original bently nevada 330103-00-15-05-01-00 330103-00-18-05-02-05 330103-00-16-10-01-00
- USA original bently nevada 330103-00-08-10-02-00 330103-00-10-05-01-00 330103-00-12-10-01-00 330103-00-14-05-02-00
Popular Searches
- phone logger
- recorder
- thermometer hygrometer
- Bath Thermometer Strip
- data measurement
- recorders
- Temperature Data Logger
- digital thermostat
- fan thermostat
- control thermostat
- temperature recorder
- temperature humidity data logger
- data recorder
- temperature humidity sensor
- Humidity Data Logger
- Usb Data Logger
Recommended Products
- Acrel ADF400L-3D 3 circuits single phase 10(80)A High accuracy
- Acrel ADF400L-4H Multi Circuit Electrical Instruments 4 channel 3 phase 3*1(6)A High installation flexibility
- Acrel Multi Circuit Electrical Instruments 2 channel 3 phase 3*10(80)A ADF400L-2S din rail
- Acrel din rail Multi Circuit Electrical Instruments 6 channel single phase 10(80)A High installation flexibility ADF400L-6D
- Acrel 6 channel three phase 3*1(6)A High installation flexibility din rail ADF400L-6H Multi Circuit Electrical Instruments
- Acrel current transmitter input AC 0-1/5A output 4-20mA power AC/DC 85-270V BD-AI
- Acrel Active power transmitter AC/DC85-270V 1 Channel analog output BD-3P
- Acrel BD-4E Multi-power digital transmitter 2 channels energy impulse output Rs485 modbus-RTU
- Acrel BD-4EA transmitter 2 channels energy impulse output Rs485 modbus-RTU Multi-power digital
- Acrel transmitter AC/DC85-270V 1 Channel analog output 4-20mA BD-4P Active powe
- Used Temperature And Humidity Test Chamber High And Low Temperature Test Chamber Climate Aging Testing Machine
- JINGYAN Low Temperature Test Chamber Constant Temperature And Humidity Machine Environmental Aging Test Chamber
Find Similar Products By Category
- Measurement & Analysis Instruments > Temperature Instruments
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Carina Wang
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-