New Products for 2014 PVC Insulated and Sheathed KVV Control Cable
Specifications
lor-coded PVC jacket single core.2.Through ULVW - 1 vertical retardant test.
3. much quantity to short times supply
Copper core PVC Insulated and Sheathed Copper wire woven shielded control cable
Standard: GB9330-88
1. The Control Cable products can be produced according to the standard GB/T9330-2008, and Control Cables are suitable for the connection of controlling electrical equipment and instrument meters, monitoring and controlling return circuit, protecting and measuring in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.
2. Type of Control Cable: KVV Control Cable, KVVP, KVVP2, KVV22, KVV32, KVVR, KVVRP, KYJVP, Control Cable.
3. Service Conditions
(1)The long-time working temperature of conductor of PVC insulated cable is 70oC
(2)The temperature for laying the cables can't be lower than 0oC. Permissible bending radius(3): Unarmoured cable: R≥ 6D; (D: Outer diameter of the cable); Armoured or copper-tape screened cable: R≥ 12D; Shielded flexible cable: R≥ 6D

TYPE |
NAME |
Section Area(mm 2 ) |
|
|
|||||
|
0.75 |
1 |
1.5 |
2.5 |
4 |
6 |
10 |
|
|
|
No. of Core |
Application Site |
|||||||
KVV |
Copper Conductor, PVC Insulated and Sheathed Control Cable |
2-48 |
2-14 |
2-10 |
Permanent installation indoors, in cable ditches or pipes |
||||
ZR-KVV |
Flame Retardant Copper Conductor, PVC Insulated and Sheathed Control Cable |
||||||||
NH-KVV |
Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed Control Cable |
||||||||
KVVP |
Copper Conductor, PVC Insulated and Sheathed, Braiding Shielded Control Cable |
2-48 |
2-14 |
2-10 |
Permanent installation indoors, in cable ditches or pipes where shielding is required |
||||
ZR-KVVP |
Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Braiding Shielded Control Cable |
||||||||
NH-KVVP |
Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Braiding Shielded Control Cable |
||||||||
KVVP2 |
Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable |
4-48 |
4-14 |
4-10 |
Permanent installation indoors, in cable ditches or pipes where shielding is required |
||||
ZR-KVVP2 |
Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable |
||||||||
NH-KVVP2 |
Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Copper-tape Screened Control Cable |
||||||||
KVV22 |
Copper Conductor, PVC Insulated and Sheathed, Steel tape Armored Control Cable |
7-48 |
4-48 |
4-14 |
4-10 |
Permanent installation indoors, in cable ditches, directly buried, Be able to withstand stronger external mechanical force |
|||
ZR-KVV22 |
Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Steel tape Armored Control Cable |
||||||||
NH-KVV22 |
Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Steel tape Armored Control Cable |
||||||||
KVV32 |
Copper Conductor, PVC Insulated and Sheathed, Thin steel wire Armored Control Cable |
19-61 |
7-48 |
4-14 |
4-10 |
Permanent installation indoors, in cable ditches, vertical shaft Be able to withstand stronger external mechanical force |
|||
ZR-KVV32 |
Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Thin steel wire Armored Control Cable |
||||||||
NH-KVV32 |
Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Thin steel wire Armored Control Cable |
||||||||
KVVR |
Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable |
4-48 |
- |
- |
Installation indoors where flexibility and movability are required |
||||
ZR-KVVR |
Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable |
||||||||
NH-KVVR |
Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Flexible Control Cable |
||||||||
KVVRP |
Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable |
4-16 |
4-48 |
- |
- |
Installation indoors where flexibility shielding and movability are required |
|||
ZR-KVVRP |
Flame Retardant Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable |
||||||||
NH-KVVRP |
Copper Conductor, Mica tape Fire-Resistant, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable |
||||||||

Send Inquiry to This Supplier
You May Also Like
-
Sick YF8U14-050VA3XLEAX - Sensor/actuator CableNegotiableMOQ: 1 Piece
-
Fireproof CableNegotiableMOQ: 500 Meters
-
4/8/16/32CH Channels Multi Cable With Wheel/6 UTP Multipair CableUS$ 500 - 800MOQ: 10 Pieces
-
Polyamide-Imide Enamelled Copper Wire Class 220 Aiw/220 High Temp ResistantNegotiableMOQ: 500 Kilograms
-
Suitable For Outdoor Use Coated Electrical WireUS$ 1 - 10000MOQ: 1 Piece
-
QYYEQ Electric Submersile Power Cable With Excellent Oil Resistance PropertiesUS$ 10 - 30MOQ: 100 Meters
-
Competitive Price LMR400 Coaxial CableNegotiableMOQ: 10 Kilometers
-
Wire and CableNegotiableMOQ: 2000 Rolls
-
Factory Price High Quality 1mm 1.5mm 2mm 2.5mm 4mm Aluminum Enamelled Winding Electrical WireUS$ 3.23 - 3.96MOQ: 1000 Kilograms
-
Advanced Self-Regulating Heating Cable for Freeze Protection & Temperature MaintenanceUS$ 0.98MOQ: 10 Meters