Home > Products > Industrial Measuring & testing Instruments > Paint Thickness Measuring Gauges Which Widely Used for Metal Surface Coating
Paint Thickness Measuring Gauges Which Widely Used for Metal Surface Coating
- Ningbo/Shanghai
- T/T Credit Card
You May Like
-
Easy Operational fn Series Car Paint Coating Thickness Measuring Applicator Gauges Instruments
-
Newest Calbration Design of Digital Car Paint Coating Thickness Gauge
-
1500um Car Paint Coating Thickness Measuring Applicator Tester
-
China High Accuracy Car Paint Coating Thickness Gage
-
Auto Recognize F&NF Probe Car Paint Coating Thickness Test Tool
-
Dual Probe Auto Recognize F&NF Probe Zinc Paint Coating Thickness Measuring Instrument
Product Details
| Place of Origin | China | Brand Name | PULANI | |
| Model Number | 2013PLN-YT |
Product Description

Basic instructions:
1 . Automatic shutdown time: 30s
2.There are 4 kinds of state mode : measurement status, Statistics status, view data
status , calibration status.
A) Measurement status: display of measured values.
B)View data status :20 sets of historical data through.
C) Statistics status: maximum, minimum, average value.
D) Multi-point Calibration status :
F) Auto Calibration status : calibration measurements, and the gauge has 6 kinds of
calibration mode of 0.0 um, 50um, 100 um,250um ,500 um.
Key function instructions
K1 (+) function :
A :Short press K1 (+), When you in different status, it will show you different function as
below :
1) In the measurement status,short press “+”, the unit will be switch from um to mil .
2) In the view data status,short press “+”, it can turn up to show the data .
3)In the statistics status of “MAX” ,short press “+”,the background light will be off .
4)In the calibration status, short press”+”,it can switch 6 kinds of calibration mode of 0.0 um,
50um, 100 um,250um ,500 um in turn.
B: long press K1(+), When you in different status, it will show you different function as
below :
1)In the measurement status, long press “+”, it will enter to the multi-point calibration mode
2)In the view data status, long press “+”, delete a single data selected
3)In the statistics status of “MAX”, long press “+” , it could be light on /off the background
light, but if the screen is black one ,you can not see the data.
4)In the auto calibration status: exit the calibration status to the measuring status
K2 (MENU)function
A: short press K2(menu),When you in different status, it will show you different function as
below :
1)In the Non-calibration status: measurement status, view data status and statistics status
be switched in turn.
2)In the both of auto and multi-point calibration status: exit the calibration status to the view
data status
B: long press K2(menu),When you in different status, it will show you different function as
below :
1)In the auto measurement status: enter the auto calibration status
3)In the statistics status and View data status: invalid
K3 (-)function
A: short press K3 (-)
1)View data status: turn down to show the data
2)Statistics status: invalid
3)The calibration status: switch 6 kinds of calibration mode of 0.0 um, 50um, 100
um,250um ,500 um in turn .
B: long pressK3 (-):
1)In the Measurement status: restore factory (it will removal of historical data and the
calibration parameters) .
2)In the View data status: clear the historical data (including 20 measurements, the
maximum, minimum and average), the calibration parameters keep constant.
3)In the Statistics status: invalid
4)In the calibration status: exit the calibration status to the measuring status

5 pcs gauges you received are with sample package. Now there are 2 types of regular package:
(1) 1 complete set of gauge package: 1 pcs gauge, 1 set calibration, 1 instruction, 1 black glasses box.
(2) 5 complete sets of gauge package: 5 pcs gauge, 5 sets calibration, 5 instructions, 5 black glasses boxes, 1 white carton box whose outside is with the color cover.
1) How the coating thickness gauge shut down?
A: Our coating thickness gauge adopt with automatic shutdown, when you stop using it, it will be shutdown automatic after 30 seconds.
2) What angle should be kept with Coating thickness with the analyte ?
A: The probe must be kept perpendicular to the surface with the measured material, otherwise it will lead to considerable error.
3) How to maintain accuracy of measurement when we need repeatedly measurements ?
A: When we need repeatedly measure, the thickness gauge should be keep the distance more than 3cm away from the analyte and at least keep 2 seconds or more interval .(Attention :Do not drag along the surface to the side of the probe to avoid probe magnetization.it will be impact of next measurement result)
4) When should we to calibrate the Coating thickness ?
A: Our thickness gauge has been calibrated , in most time, we just need to check whether the uncoated substrate is normalized to zero .Usually when the measurement accuracy beyond the precision values ,it need to be calibrated (refer to the instructions precision value range) . Calibration method according to operating instructions.
5) When the Coating thickness display with"" ,What does it mean?
A: It indicates that the battery voltage is low, please replace the battery in the automatic shutdown, otherwise it will affect the measurement accuracy.
6) How to choose the zero substrate?
A: The thickness of zero substrate should be used as the test material to avoid the permeability of different materials and measurement errors.
7) How to choose the zero substrate surface?
A: Use the gauge should be in the same part of the material being tested after calibrating to zero, and then measuring the same part. If the measuring pipe, bar and other curve surface materials, but the user indeed calibrating to zero with substrate of flats surface , this will affect the accuracy of the measurement. And choose the calibrating zero surface should be more smooth.
8) Coating thickness gauge has been calibrated, why also the measurement also not accurately?
A: The coating thickness calibration could not choose the substrate random ,firstly calibrating to zero based on the same test material of substrate which without coating , then put the calibration sheet in the top to calibrate, so that could get reliable measurement data. Remember: Be sure to use the same shape, the same material, the same roughness zeroing calibration substrate.
9) Why the different coating thickness measured data is not the same?
A: Due to different coating thickness gauge calibrated with different substrate before use . For consistency, we should make them in the same uncoated substrate to do the zero calibration, and then put the calibration sheet in the top to calibrate, so different coating thickness measurement data will be keep consistent.
10) When should we to replace to Standard film ?
A: The coating thickness calibration depends on the calibration sheet, so it is very important that keep the calibration sheet in good condition. If the calibration sheet has been used for many years and not in a good condition, please replace it . Otherwise, the measurement data will be inaccurate.
Contact Us
- Hangzhou Pulani Electronic Technology Co., Ltd.
- Contact nameDemi Guo Chat Now
- Phone86-571-85829611
- AddressBlock D,Floor 14th ,Chunxiao Court,Zhongshan Garden, No. 221, Zhaohui Road, Hangzhou, Zhejiang
Product Categories
| Automobile & Motocycle Electronic Products | Industrial Measuring & testing Instruments | New Products |
New Products
-
Auto Recognize F&NF Probe Dry Film Coating Thickness Gauge
-
Auto Recognize F&NF Probe Thin / Dry Film Thickness Measurement Systems Guages Meter
-
Digital Car Paint Coating Thickness Gauges
-
Large LCD Display, Manufacturer Magnetic Car Paint Coating Thickness Gauges Tester Meters
-
Smart Zinc Coating Thickness Tester
-
Mini Digitally Designed Zinc Coating Thickness Gauge
-
Coating Thickness Gauge for Measuring Metal Surface Coating
-
Smart Portable Digital Coating Thickness Meauring Checker
-
Coating Thickness Tester Which More Popular and Useful in Auto Industry
-
Smart New Calibration Tech Coating Thickness Tester Device
-
Smart Hot Sell Coating Paint Thickness Measuring Tester
-
Optimized Ergonomic Designed 2 in 1 Easy Operate Auto Paint Thickness Test Tool
-
MINI Design Coating Paint Thickness Measuring Tool
-
New Udapted Max 1700um Digital Coating Thickness Gauge Widely Used for Second Car Paint Checking
-
2016 Popular New Digital Paint Coating Thickness Gauge
-
Professional Type Coating Thickness Gauge With USB Port Which Coule Put the Data to PC
-
China Made Paint Coating Thickness Gauge
-
Handheld Digital Coating Thickness Measuring Meter for Auto Industry
-
Digital Big Scrren Coating Thickness Tester
-
DIgital Elcometer Coating Thickness Gauge of Different Color
-
Digital Handheld Coating Thickness Check Tool for Car Industry
-
Digital Coating Thickness Meter for Galvanized
-
Only Need do Zero Calibration Coating Thickness Gauge
-
Max Measuring Range of 1700um Galvanizing Coating Thickness Measuring Tool
Popular Searches
- wooden table easel
- ruler set
- plastic ruler
- 3d lenticular ruler
- drawing ruler
- bamboo easel
- flexible ruler
- tailor ruler
- pvc ruler
- office ruler supply
- ruler stationery
- metal ruler
- promotional ruler
- office ruler
- student ruler
- plastic flexible ruler
- ruler 15 cm
- measuring tap
- digital body fat caliper
- bamboo ruler
- magnetic measuring spoon
- drafting board
- magnifier ruler
- straight ruler
- silicone measuring cups and spoon
- silicone measuring cups spoon
- transparent ruler
- plastic scale ruler
- logo printing ruler
- acrylic ruler
Recommended Products
- Large-range 0-200mm Digital Height Gauge
- China Wholesale Stadiometer Measure Tape of Measurement Tool 3m Measuring Tape
- Popular Model High Quality 5 Meter Multifunction Tape Measure Promotion Steel Measuring Tape
- Digital Indicator Measuring Aids
- Digital Internal Micrometer
- Digital Radius Gauge
- Digital Thin-rod Depth Gauge
- Digital Thickness Gauge
- Digital Hardness Tester
- Height Gauge
- ZB01F Type Hand Press Sampling Knife
- ZB01B Type Disc Sampling Knife
Find Similar Products By Category
- Instruments & Meters > Weighing & Measuring Apparatus > Measuring Device
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Demi Guo
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile






Easy Operational fn Series Car Paint Coating Thickness Measuring Applicator Gauges Instruments
Newest Calbration Design of Digital Car Paint Coating Thickness Gauge
1500um Car Paint Coating Thickness Measuring Applicator Tester
Auto Recognize F&NF Probe Car Paint Coating Thickness Test Tool
Dual Probe Auto Recognize F&NF Probe Zinc Paint Coating Thickness Measuring Instrument













Auto Recognize F&NF Probe Dry Film Coating Thickness Gauge
Auto Recognize F&NF Probe Thin / Dry Film Thickness Measurement Systems Guages Meter
Large LCD Display, Manufacturer Magnetic Car Paint Coating Thickness Gauges Tester Meters
Mini Digitally Designed Zinc Coating Thickness Gauge
DIgital Elcometer Coating Thickness Gauge of Different Color