Home > Products > CAST RESIN TRANSFORMER > Dry-type Transformer 6900 volts
Dry-type Transformer 6900 volts
- 0 per Month
- T/T L/C
Product Details
Place of Origin: | Gujarat, India | Brand Name: | PEC | Model Number: | 6900 volts |
Usage: | Power | Phase: | Three | Coil Structure: | Other, epoxy |
Coil Number: | Other, 3 |
Product Description
Specifications
CAST RESIN TRANSFORMER 500 kvaregistered company engaged in the manufacturing Industrial Transformers
manufacture of Industrial Transformers Epoxy Cast Resin Construction Dry Type, Oil Cooled low and medium voltage Industrial Automatic Voltage Controller ranging up to 7000 KVA capacity (U.K. based Brentford type), Variable voltage supply UPTO 33000 Volts Special Purpose Transformers step up step down auto transformers Ultra Isolation Transformers Rectifier equipment 1500 Volts and up to 25000 Amps. for Industrial applications.
Rated power [kVA] | Rated voltage [kV] | No-load losses [W] | Load Losses [W] | Total Weight [kg] | Dimensions |
| |||
Lenth [mm] | Width [mm] | Height [mm] | |||||||
100 | 12 | 320 | 1600 | 760 | 1230 | 70 | 890 | ||
| 24 | 400 | 1500 | 830 | 1300 | 755 | 940 | ||
160 | 12 | 440 | 2300 | 920 | 1290 | 720 | 1050 | ||
| 24 | 580 | 2200 | 940 | 1310 | 720 | 1095 | ||
250 | 12 | 600 | 3000 | 1170 | 1330 | 730 | 1135 |
| |
| 24 | 800 | 2900 | 1230 | 1400 | 735 | 1150 |
| |
| 36 | 1300 | 3800 | 1700 | 1900 | 900 | 1350 |
| |
315 | 12 | 720 | 3300 | 1320 | 1380 | 820 | 1195 |
| |
| 24 | 930 | 3400 | 1400 | 1440 | 825 | 1205 |
| |
| 36 | 1450 | 4500 | 1900 | 1950 | 920 | 1400 |
| |
400 | 12 | 880 | 4300 | 1430 | 1380 | 820 | 1290 |
| |
| 24 | 1100 | 3900 | 1570 | 1460 | 830 | 1280 |
| |
| 36 | 1700 | 5100 | 2100 | 2000 | 920 | 1440 |
| |
500 | 12 | 1350 | 4900 | 1520 | 1410 | 830 | 1320 |
| |
| 24 | 1270 | 4800 | 1830 | 1540 | 840 | 1350 |
| |
| 36 | 1900 | 6000 | 2600 | 2050 | 940 | 1500 |
|
Contact Us
- POWER ENGINEERS COMPANY
- Contact nameATUL KHOSLA
- Phone91-9714-777713
- Address967/2/2, GIDC, MAKARPURA,
- Acrel leakage current transformer rated current 400-800A Applied to residual current signal collection AKH-0.66/L L-150
- Acrel measuring rated current 250-400A low voltage leakeage CT Residual current transformer AKH-0.66/L L-100
- Acrel Applied to residual current signal collection residual current transformer AKH-0.66/L L-200 rated current 800-1500A
- Acrel AKH-0.66/L L-80 rated current 100-250A Applied to residual current signal collection measurement current transformer
- Acrel leakage current transformer rated current 400-800A Applied to residual current signal collection AKH-0.66/L L-150
- Acrelrated current 800-1500A Applied to residual current signal collection residual current transformer AKH-0.66/L L-200
- Acrel AKH-0.66/L L-45 residual current transformer rated current 16-100A Applied to residual current signal collection
- Acrel Can be widely used in industrial automation fields smart AC current transformer BA20(II)-AI/V
- Acrel smart AC electrical transducer BA50(II)-AI/V Mainly detects the leakage current of the electrical system
- Acrel BA50L(II)-AI/V smart AC electrical current sensor Can be widely used in industrial automation fields out 1-5V/0-5V
- Acrel BA50L(II)-AI/V Can be widely used in industrial automation fields out 1-5V/0-5V smart AC electrical current sensor
- Made in China Three phase dry type transformer SG-100VA for thermal power plant
- Flyback transformer
- Lan transformer
- НЕФТЯНОЕ МЕСТОРОЖДЕНИЕ SHENGDONG SHENGLI газогенератор мощностью 500 кВт T12V190
- shengdong shengli oil field 500KW natural gas generator T12V190ZL
- B6190 G6190 200KW diesel engine used in ship boat spare parts
- B12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- BH12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- AL12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- BL12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600lw
- Acrel smart AC electrical current sensor BA50L(II)-AI/V Can be widely used in industrial automation fields out 1-5V/0-5V
- Acrel BA50L(II)-AI/I AC current sensor in AC0-(0.1-1)A out 4-20mA/0-20mA Real-time monitoring of AC current in the power grid
- Acrel BA50(II)-AI/V AC electrical transducer Mainly detects the leakage current of the electrical system
Popular Searches
- power transformer
- Distribution Service
- current transformer
- power transformers
- High Frequency Transformer
- Electrical Transformer
- energy saver device
- led transformers
- step up converter
- Ac Drive Converter
- Frequency Drive Converter
- electronic transformer
- Lighting Transformers
- toroidal transformer
- auto transformer
- voltage transformer
Recommended Products
- 6.5kw ~ 1000kw Stamford AC 3phase Electric Alternator for Diesel Gensets
- 280kw to 2000kw Diesel Power Electric Generator Powered by Baudouin for Industrial Use
- 26700 3.2V 4000mAh 4500mah 5000mAh 6000mAh Lithium Iron Phosphate Battery
- SAFRAN CIRCUIT BREAKER 4200 series
- SAFRAN CIRCUIT BREAKER 160 series
- For Building Data Acquisition HVAC Monitoring and Control BACnet/IP IO Module
- Supports VPN and TLS/SSL Data Encryption Flexible EdgeIO Controller
- AXON Radio frequency coaxial connector
- 800PP846A Operation panel Provides greater visibility into the process
- TRICONEX 3721 Communication module Multiple sensors can be connected
- PM150V08 3BSE009598R1 High performance processor module Multiple control tasks can be handled simultaneously
- MS-NAE5510-3 Ethernet-based monitoring devices Higher data transfer rate
Find Similar Products By Category
- Electrical Equipment & Supplies > Transformers
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
ATUL KHOSLA
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-