SM-500S Portable Patient Monitor
- 0 per Month
- T/T L/C D/P D/A Credit Card PayPal
- Veterinary Ultrasound Scanner Animal Ultrasound Detector Essential Instrument for Pet Care
- Medical Sonar Ultrasound Vet Handheld Pig Sheep Pregnancy Ultrasound Machine
- Vet veterinary ultrasound machine handheld ultrasound echo scanner for cow
- Handheld Digital Veterinary Ultrasound Canine Horse Pigs Cow Pregnancy Animals Portable Device Vet Ultrasound
- Medical animal veterinary instrument ultrasound machine price for vet ultrasound pregnancy scanner
- Hysteroscopy : Display + Camera system + light source + Trolley + Hysteroscope + Gynecology Resectoscope + Electronic surgical Unit + Endoscopy Pump
Product Description
Specifications
12" color TFT display, up to 12 waveformsOne level menu, easy to use
Arrhythmia analysis, ST calculation, Pace analysis
Features:
-12" color TFT display, up to 12 waveforms
-One level menu, easy to use
-Parameters including ECG/RESP, SpO2 , NIBP, TEMP, Pulse Rate and IBP(optional)
-Maximum 720 hour graphic and tabular trends of all parameters
-Built-in recorder and battery
-Suitable for adult, pediatric and neonatal patient
-Arrhythmia analysis, ST calculation, Pace analysis
-Anti-ESU, anti- defibrillator
-Standard network interface, can connect to Central monitor system
Main Functions:
1. 12 widescreen TFT, Resolution ratio: 800600, up to 12 waveforms ;
2. Display ECG, SpO2, pulse rate, NIBP, respiration, temperature
3. Plumbic acid battery.
Optional:
1. Recorder(Built-in)
2. CO2
3. Anesthesia depth
1 Classification
Item | Specification | |
SFDA classification | Class II | |
Anti-electroshock degree | Class I equipment with internal power supply | |
Anti-electroshock degree | TEMP/SpO2/NIBP ECG/RESP | BF CF |
Explosion proof level | Ordinary equipmentwithout explosion proof | |
Harmful liquid proof degree | Ordinary equipmentwithout liquid proof | |
Working system | Continuous running equipment |
2applicable standards
Medical electrical equipment GB 9706.1-2007, Part I: General requirements for safety
GB 9706.25-2005 Medical electrical equipment Part 2-27: ECG monitoring equipment safety requirements
YY 1079-2008 ECG
YY0667-2008 Medical electrical equipment Part 2: Automatic cycling non-invasive blood pressure monitoring equipment, safety and essential performance
YY0668-2008 Medical electrical equipment Part 2: multi-parameter patient monitoring equipment requirements for the safety
3 monitor size and weight
size 300 275 150 mm
Weight 4 kg
4 Power Supply
100~240 VAC, 50/60 Hz, Pmax=90VA Fuse T1.5A
5Battery
2.6 Ah 12V rechargeable battery
Operating time after full charge is more than 1 hours
Operating time after the first alarm of low battery will be about 5 minutes
Maximum charging time is less than 6 hours.
6 Signal Interface
Network interface standard RJ45 Socket
7 Storage
Trend 720 hours
NIBP review 1000 NIBP events
Wave review 2 hours
Alarm review 200 alarm events
All storage data are non volatile.
8 Environment
8.1 Temperature
Working 0 ~ 40 C
Storage -20 ~ 50C
8.2 Humidity
Working 15% - 90 %(no coagulation)
Storage 15% - 90 % (no coagulation)
8.3 Atmospheric pressure
Working 86.0 kPa ~ 106.0kPa;
Storage 86.0 kPa ~ 106.0kPa
9ECGSpecification
9.1Heart rate calculation method
Since the first occurrence of heart rate to heart rate occurred in the second interval T1; second heart rate, heart rate occurred to a third place time interval T2; continuous record 10 times, and then calculated the average interval of 10, must the heart rate per minute. 3s ~ 10s refresh every heart.
9.2 Heart rate meter accuracy and arrhythmia response
Monitor the 20s stable time after figure ECG heart rate a wave group): heart rate display 40bpm5bpm; b): heart rate display 30bpm5bpm; c): heart rate display 120bpm5bpm; d): heart rate display 45bpm5bpm
A) Couple rhythm two waves of duration is 1500ms; if the calculation all the QRS complex, heart rate to 80bpm, if only large R wave or S-wave, the heart rate to 40bpm.
B) Slow change couple rhythm if the calculation all the QRS complex, heart rate to calculate 60bpm, if only large waves, heart rate to 30bpm.
C) Fast couple rhythm if the calculation all the QRS complex, heart rate as 120bpm.
D) bi-directional contraction if you calculate the QRS complex, heart rate to calculate 90bpm, if only large waves, heart rate to 45bpm.
9.3 Lead mode
5 Leads: RALALLRLV; lead mode: I, II, III, AVR, AVL, AVF, V
9.4Gain
Gain control: manually four stalls
1/4 stalls(0.25) 2.5mm/mV; 1/2 stalls (0.50) 5.0mm/mV; 1 stall (1) 10mm/mV; 2 stalls (2) mV 20mm/mv;
9.5 Heart rate
Measure range:
Adult 15 ~ 300 bpm
Neonatal/Pediatric 15 ~ 350 bpm
accuracy 1%
resolution 1 bpm
9.6 Sensitivity
> 200 V P-P
9.7 Differential Input Impedance
> 5 M ohm
9.8 Bandwidth
Surgery 1 ~ 20 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
9.9 CMRR
Diagnostic Mode >90 dB
Monitor Mode >110 dB
Surgery Mode >110 dB
9.10 Electrode offset potential
300mV
9.11Input dynamic range
In any lead, the applied DC bias voltage of 300mV to 320mV / s rate of change of 5mV of the differential mode voltage, and display devices should have the capacity to respond; output signal amplitude error should not exceed 10% ;
9.12 pacing pulse suppression
Monitor switch is open in the pacemaker, can inhibit the range: 2 mV ~ 700mV, width: 0.1ms ~ 2ms, rise time: 10us ~ 100s normal QRS wave single pulse without overshoot pacing pulse does not affect heart rate calculation.
Monitor switch is open in the pacemaker, can inhibit the range: 2 mV ~ 5mV, width: 0.5ms ~ 2ms, rise time: 10us ~ 100s single pulse overshoot normal QRS waves of pacing pulses, without affecting heart rate calculation.
Overshoot (a0) range should 0.025ap to 0.25ap range, independent of the choice of time constant, but not more than 2mV;
Monitor switch is open in the pacemaker, pacing pulse detector inhibition of rapid ECG signal to 1V / s RTI minimum input slew rate.
9.13 QRS wave amplitude and period range between
Amplitude (p-v RTI) range: 0.5mV ~ 5mV;
Width (adult monitor): 70 ~ 120ms;
Width (neonatal / pediatric): 40 ~ 120ms;
Set monitor mode for adults should not be less than or equal to 0.15mV amplitude QRS signal or of less than or equal to 10ms between the 1mV signal a response. For neonatal / pediatric mode, monitors allowed to respond to the above two signals to respond to either or both;
9.14 frequency voltage tolerance
Superimposed on a QRS wave signals received, and to meet tolerances of 10% of heart rate showed the error limits of accuracy required under the premise of the maximum frequency sine wave peak - valley kurtosis should not be less than 100V (pv)
9.15 drift tolerance
When a 0.1Hz, amplitude 4mV (pv) of the triangular wave superimposed on a string of rate of 0.5mV, interval 100ms, repetition rate of 80bpm when the QRS wave, ECG heart rate monitor shows the error should be within 80bpm 8bpm;
9.16 baseline control and stability
Reset: reset recovery time is not greater than the 3s;
Baseline Stability: After boot, 10s baseline drift in the output rate should not exceed 10V / s RTI;
After boot, 1h, total drift should not exceed 500V / s RTI;
Working temperature should not exceed 50V /
9.17 system noise
Should be not more than 30V (p-v RTI)
9.18 Multi-channel crosstalk
Should not be imposed by the channel signal is not imposed without the signal channel output generated more than spin plus signal (multiplied by the gain) 5%;
9.19 Electro surgery interference suppression
Heart rate should not exceed the interference is not activated when the heart rate 10%, interfere with the duration should not exceed 10S;
9.20 pacemaker pulse display capabilities
Show an increase is not less than 0.2mV RTI; in 10s, the baseline drift is not greater than 10mm;
9.21 heart rate response time
Step increase in heart rate from 80bpm to 120bpm maximum response time of less than 10 s;
Heart rate from 80bpm to 40bpm step to reduce the maximum response time of less than 10 s;
9.22 to the alarm time
High heart rate alarm start time is less than 10 s by YY 1079-2008;
Low heart rate alarm start time is less than 10 s according to YY 1079-2008;
Cardiac stop alarm start time is less than 10 s by YY 1079-2008;
Tachycardia alarm start time is less than 10 s.
9.23 calibration signal
1mV (peak to peak), the accuracy 5%
10 NIBP Specifications
10.1 Measurements
Pulse wave oscillation
10.2 Mode
Manual / Automatic / Continuous
10.3 Automatic measurement mode of measurement interval
1 minute, 2 minutes, 3 minutes, 4 minutes, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 60 minutes, 90 minutes, 2 hours, 3 hours, 4 hours, 8 hours
10.4 Continuous measurement mode of measurement time
5 minutes
10.5 pulse rate range
40 - 240 bpm
10.6 Measurement range and accuracy
Range
40 ~ 280mmHg systolic blood pressure for adults
Diastolic blood pressure 10 ~ 220mmHg
The average pressure of 20 ~ 240mmHg
40 ~ 220mmHg systolic blood pressure of children
Diastolic blood pressure 10 ~ 160mmHg
20 ~ 170mmHg mean pressure
Newborn systolic blood pressure 40 ~ 135mmHg
Diastolic blood pressure 10 ~ 100mmHg
The average pressure of 20 ~ 110mmHg
Static pressure range 0 ~ 300mmHg
3mmHg static pressureAccuracy
5mmHg;Blood pressure accuracy: the maximum average error of
Maximum standard deviation 8mmHg
10.7 overvoltage protection
Adult model 300 mmHg
Child model 240 mmHg
Neonatal model 150 mmHg
11 SpOSpecifications
11.1 oxygen saturation
Measuring range 0 to 100%
Resolution 1%
2%Accuracy of 70 ~ 100%:
<69%: not defined
11.2 pulse rate
Range 20 ~ 250bpm
Resolution 1bpm
3bpmAccuracy
12 temperature specifications
Sensor type 10K series, 2.25K Series
Number of channels 2 channels
CRange 0 ~ 50
CResolution of 0.1
C (sensor error not included) 0.1 Accuracy
13 recorder (optional)
Record width of 48 mm
Walking paper speed 25/50 mm / s
2-channel waveform tracings
Contact Us
- Guangzhou Sonostar Technologies Co., Limited
- Contact nameSonostar Cai
- Phone86-020-32382095
- AddressFloor 5, building C, No. 27, Yayingshi Road, Science City Guangzhou,Guangdong
- Arthroscopy : Display + endoscopic imaging system + light source + Trolley + Arthroscope + Irrigation Pump + Arthroscopy Shaver
- DP10 Mindray Black White Ultrasound machine, Portable Ultrasound Machine, Mindray Ultrasound Machine
- DP-2200plus Mindray Black White Ultrasound machine, Portable Ultrasound Machine, Mindray Ultrasound Machine
- Ophthalmology Slit Lamp,Digital Slit lamp
- Trolley Color Ultrasound machine, Cart Color Doppler,4D color ultrasound
- Trolley Color Ultrasound machine, Cart Color Doppler,4D color ultrasound
- SONY Medical Printer,SONY Printer for B/W Ultrasound, SONY Thermal Printer
- C20 Color Ultrasound machine, Color Doppler
- Pulse oximeter
- Color Doppler ultrasound diagnostic instrument
- Doppler ultrasound diagnostic system
- B/W Ultrasound machine, Black and White Ultrasound
- Color Ultrasound machine, Color Doppler
- Circular light source board Circular light source CCD
- Ring light source with high power Camera light source lighting Circular light source board Circular light source CCD
- Ring light source with high power Camera light source lighting Circular light source board
- Ring light source with high power Camera light source lighting Circular light source at 75 degrees
- LED light source blue 24V white Camera light source lighting Circular light source at 75 degrees
- LED light source blue 24V white Camera light source lighting
- LED light source blue 24V white Camera light source
- LED light source blue 24V white
- CCD industrial camera defects LED light source blue 24V white
- Machine vision light source strip metal glass surface CCD industrial camera defects LED light source blue 24V white
- Guangdong Industrial Visual Bottom Light Source Wholesale ManufacturerRing light source maCircular light source at 75 degreesnufacturerCircular light source diffusion plateRing light source with high power
Popular Searches
- Ultrasound Bone Densitometer
- portable bone densitometer
- welch allyn ophthalmoscope
- streak retinoscope prices
- chison eco1 ultrasound best price
- uprobe-2 wireless ultrasound probe
- doppler color ultrasound machine toshiba
- palmtop ultrasound scanner
- olympus gif gastroscope
- digital endoscopes
- ophthalmic yag laser
- used endoscopy
- ultra sound machine
- autorefractor keratometer
- colonoscope olympus
- endoscopy olympus
Recommended Products
- Medical Grade Thermometer for Adults Heavy Duty Forehead Thermometer for Adults and Kids Clinical Accurate Digital Thermometer Touchless 32 Memory Body & Surface Mode Support customizable
- Acne Spot Face Patches for Facial Care Miracle Overnight Spot Cover Skincare for Acne Free and Pimple Free Made in Korea
- High Quality OEM Hydrocolloid Acne Patch with Excellent Effect Pimple Patches Manufacturer from Korea
- β-Conglycinin test kits (ELISA method)
- y attributesSamplesRatings & ReviewsKnow your supplierProduct descriptions from the supplier wholesale Tape Eyelash Sensitive Skin White Lash Extension Tape Pe Breathable Isolation Lash Tape vendor
- Red Powder Vitamin B12 (Food Grade CAS 68-19-9)
- High Quality Vb12 Vitamin B12 CAS 68-19-9
- High Purity API Nutrition Vitamin B12 Cyanocobalamin CAS No 68-19-9
- Hot Sales Folic Acid /Biotin /Inositol Vitamin a /C / E / D Vitamin B1 B3 B5 B6 B7 B9 B12/L-Arginine /L-Lysine/L-Isoleucine Vitamin Raw Powder
- Hot Sale Vitamin B9 Feed/Food Additives Pharmaceutical Grade Raw Powder Folic Acid Vitamin a/Vitamin C/Vitamin D/Vitamin B1/B5/B6/B7/B9/B12/Vitamin E
- Dental stainless steel nickel titanium root canal files
- blood pressure monitor digital blood pressure monitor Wrist electronic blood pressure monitor home blood pressure monitor
Find Similar Products By Category
- Health & Medical > Medical Devices > Ultrasonic, Optical, Electronic Equipments
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Sonostar Cai
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-