Home > Products > Heating or Cooling Heat Pump > High efficient Air to water EVI heat pump for Low ambeint temperature area (low to -25C) Quality Choice
High efficient Air to water EVI heat pump for Low ambeint temperature area (low to -25C) Quality Choice
- 1000 Set / Sets per Month
- SHUNDE GUANGZHOU
- Credit Card
- R290 DC Inverter Heat Pump for Heating, Cooling and DHW
- Customized 50liter stainless steel household square heat heat pump thermal storage buffer water tank
- Gas Shortage Remedies 50 liter luftwarmepumpen heat pump hot water buffer tank no coil for house floor heating
- Customized Commercial Domestic Heat Pump Water Heater 100L 200L 300L Hot Water Tank Storage Heat Pump Water Tank For House
- Economical Energy Conservation Domestic Hot Water Combined Tank For Heat Pump System Water Heater 300l Tank 316 Stainless Steel
- Economical Energy Conservation Domestic Hot Water Combined Tank For Heat Pump System Water Heater 300l Tank 316 Stainless Steel
Product Details
Type: | Other, air to water heat pump | Installation: | Freestanding | Storage / Tankless: | Instant / Tankless |
Housing Material: | Other, plastic or stainless steel | Use: | Other, heating , cooling or hot water | Certification: | CB, CE, CSA, EMC, Other, CB, CE, CSA, EMC, RoHS, SAA,C-TICK,ETL |
Place of Origin: | Guangdong, China | Brand Name: | MACON | Model Number: | MACHRW050ZA/S(E01D) |
Product Description
Low temperature water heat pump EVI heat pump
Indoor Unit Model | MACHRW | 040W/PS(E01) | 050W/PS(E01) | 060W/PS(E01) | 080W/PS(E01) |
Outdoor Unit Model | MAFP | 040A | 050A | 060A | 080A |
Rated Hot Water Output | L/h | 300 | 375 | 450 | 600 |
Cooling: DB 35℃/WB 24℃, water inlet temp. 12℃, water outlet temp. 7℃ | |||||
Rated Cooling Capacity | KW | 10.0 | 12.5 | 15.0 | 20.0 |
Rated Input Power (Cooling) | KW | 3.51 | 4.39 | 5.26 | 7.02 |
Rated Input Current (Cooling) | A | 6.7 | 8.3 | 10.0 | 13.3 |
Hot Water: DB 20℃/WB 15℃, water inlet temp. 15℃, water outlet temp. 55℃ | |||||
Rated Heating Capacity | KW | 14.0 | 17.5 | 21.0 | 28.0 |
COP | W/W | 4.65 | 4.65 | 4.65 | 4.65 |
Rated Input Power | KW | 3.01 | 3.76 | 4.52 | 6.02 |
Rated Input Current | A | 5.7 | 7.2 | 8.6 | 11.4 |
Heating: DB 7℃/WB 6℃, water inlet temp. 40℃, water outlet temp. 45℃ | |||||
Rated Heating Capacity | KW | 11.0 | 13.8 | 16.5 | 22.0 |
COP | W/W | 3.26 | 3.26 | 3.26 | 3.26 |
Rated Input Power | KW | 3.37 | 4.22 | 5.06 | 6.75 |
Rated Input Current | A | 6.4 | 8.0 | 9.6 | 12.8 |
Power Supply | V/PH/Hz | 380/3/50 | 380/3/50 | 380/3/50 | 380/3/50 |
Max. Running Current | A | 10.0 | 12.5 | 15.0 | 20.0 |
Application Ambient Temperature | -25℃~43℃ | ||||
Noise @ 1m | dB(A) | 54 | 54 | 55 | 58 |
Compressor | Hitachi EVI Scroll Compressor | ||||
Heat Exchanger | GEA 316 Plate Heat Exchanger | ||||
Evaporator | Hydrophilic Aluminium Fin Heat Exchanger | ||||
Refrigerant Control Valve | SanHua Electronic Expansion Valve | ||||
Water Inlet/ Outlet | inch | 1″ | 1″ | 1″ | 1-1/4″ |
Water Flow Volume | m³/h | 2.41 | 3.01 | 3.61 | 4.82 |
Refrigerant Type | R410a/R407C | ||||
Indoor Unit Net Dimensions (L/M/H) | mm | 670/600/760 | 670/600/760 | 780/670/765 | 1205/730/800 |
Indoor Unit Shipping Dimensions (L/M/H) | mm | 720/640/910 | 720/640/910 | 830/720/865 | 1330/760/950 |
Outdoor Unit Net Dimensions (L/M/H) | mm | 880/420/800 | 930/440/1270 | 930/440/1270 | 1105/515/1545 |
Outdoor Unit shipping Dimensions (L/M/H) | mm | 1020/450/950 | 1080/480/1420 | 1080/480/1420 | 1210/540/1690 |
Indoor Unit Net Weight | kg | 100 | 110 | 115 | 150 |
Indoor Unit Gross Weight | kg | 115 | 125 | 130 | 180 |
Outdoor Unit Net Weight | kg | 35 | 50 | 50 | 65 |
Outdoor Unit Gross Weight | kg | 40 | 55 | 55 | 75 |
Indoor Unit Model | MACHRW | 100W/PS(E01) | 120W/PS(E01) | 160W/PS(E01) | 180W/PS(E01) |
Outdoor Unit Model | MAFP | 100A | 120A | 080A*2 | 090A*2 |
Rated Hot Water Output | L/h | 750 | 900 | 1200 | 1350 |
Cooling: DB 35℃/WB 24℃, water inlet temp. 12℃, water outlet temp. 7℃ | |||||
Rated Cooling Capacity | KW | 25.0 | 30.2 | 40.0 | 45.0 |
Rated Input Power (Cooling) | KW | 8.77 | 10.60 | 14.04 | 15.79 |
Rated Input Current (Cooling) | A | 16.7 | 20.1 | 26.7 | 30.0 |
Hot Water: DB 20℃/WB 15℃, water inlet temp. 15℃, water outlet temp. 55℃ | |||||
Rated Heating Capacity | KW | 35.0 | 42.0 | 56.0 | 63.0 |
COP | W/W | 4.65 | 4.65 | 4.65 | 4.65 |
Rated Input Power | KW | 7.53 | 9.03 | 12.04 | 13.55 |
Rated Input Current | A | 14.3 | 17.2 | 22.9 | 25.8 |
Heating: DB 7℃/WB 6℃, water inlet temp. 40℃, water outlet temp. 45℃ | |||||
Rated Heating Capacity | KW | 27.5 | 33.0 | 44.0 | 49.5 |
COP | W/W | 3.26 | 3.26 | 3.26 | 3.26 |
Rated Input Power | KW | 8.44 | 10.12 | 13.50 | 15.18 |
Rated Input Current | A | 16.0 | 19.2 | 25.7 | 28.9 |
Power Supply | V/PH/Hz | 380/3/50 | 380/3/50 | 380/3/50 | 380/3/50 |
Max. Running Current | A | 25.0 | 30.2 | 40.0 | 45.0 |
Application Ambient Temperature | -25℃~43℃ | ||||
Noise @ 1m | dB(A) | 59 | 60 | 65 | 64 |
Compressor | Hitachi EVI Scroll Compressor | ||||
Heat Exchanger | GEA 316 Plate Heat Exchanger | ||||
Evaporator | Hydrophilic Aluminium Fin Heat Exchanger | ||||
Refrigerant Control Valve | SanHua Electronic Expansion Valve | ||||
Water Inlet/ Outlet | inch | 1-1/4″ | 1-1/4″ | 1-1/4″ | 2″ |
Water Flow Volume | m³/h | 6.02 | 7.22 | 9.63 | 10.83 |
Refrigerant Type | R410a/R407C | ||||
Indoor Unit Net Dimensions (L/M/H) | mm | 1205/730/800 | 1205/730/800 | 1210/730/800 | 1210/730/800 |
Indoor Unit Shipping Dimensions (L/M/H) | mm | 1330/760/950 | 1330/760/950 | 1260/780/900 | 1260/780/900 |
Outdoor Unit Net Dimensions (L/M/H) | mm | 1105/515/1545 | 1105/515/1545 | 1105/515/1545 | 1105/515/1545 |
Outdoor Unit shipping Dimensions (L/M/H) | mm | 1210/540/1690 | 1210/540/1690 | 1155/565/1645 | 1155/565/1645 |
Indoor Unit Net Weight | kg | 170 | 180 | 200 | 380 |
Indoor Unit Gross Weight | kg | 200 | 210 | 230 | 410 |
Outdoor Unit Net Weight | kg | 65 | 75 | 75 | 110 |
Outdoor Unit Gross Weight | kg | 75 | 85 | 85 | 130 |
Outstanding Performance
1.Working ambient temperature ranges from -25℃ to 43℃. Highest outlet water temperature up to 60℃. Intelligent control with automatic load balancing technology design which allows the heat pump to work under different climates and satisfies the demand for cooling in summer, heating in winter and domestic hot water all year round.
2. Automatic antifreeze protection technology
Under standby mode, unit will detect water outlet and ambient temperature automatically, if temperatures are too low, it will enter antifreeze protection to start the water pump or heating mode to prevent the water system from freezing.
3. Equipped with heating belt on the chassis and extra refrigerant pipe under evaporator to prevent the chassis or the evaporator condensate from freezing under low temperature running and ensure thorough defrosting drainage.
4. Crankshaft heating device
Crankshaft heating device around the compressor help to avoid oil freezing in compressor, ensure reliable lubrication of compressor start-up under low ambient temperature for longer service life.
5. Automatic intelligent heating curve control
Intelligent working mode with winter heating curve, allows unit to automatically calculate water supply temperature according to outdoor ambient temperature changes. More convenient and more energy-saving.
6. Built-in unit ON/OFF and mode ON/OFF interfaces
Convenient switching control for different heat sources, central control of terminal fan coils and room thermostats. Automatic ON if any of the terminal equipment is on and automatic OFF when all terminal equipments are off.
7. Convenient modular design. Independent control or centralized control for option.
Each centralized controller can control 16 modular units to adjust automatically according to the load changes, suitable for large-scale sites where need heating and cooling like commercial plazas, hotels, factories, hospitals, schools, etc.
Performance Curve:
Multifunction Water Tank Radiator/ Convector Fan coi
Standard Export Package Keep The Product In Safety
For LCL Order: Interior Plastic Films + Plywood Case
For Container Order: Interior Plastic Films + Cartons
Our products are highly qualified by international standards. We gain various certifications such as CE, RoHS, EN14511 for European market, SAA, Water Mark, C-Tick for Australian market, ETL for North American market, etc.
Contact Us
- Foshan Macon Cooling & Heating Energy-Saving Equipment Co., Ltd.
- Contact nameJunji Zhang
- Phone86-0757-23669556
- AddressNo.12,Fuan 1st Industrial Area,Leliu Town,Shunde District Foshan,Guangdong
- Air source heat pump water heater swimming pool heat pump
- house heat pump 8kw 10kw 15kw 18kw 25kw 30kw EU Germany Poland Bulgaria Finland Netherlands Romania heat pump
- new energy heat pump split R32 8kw to 30kw Georgia Tajikistan Uzbekistan Kyrgyzstan Kazakhstan Turkmenistan heat pump
- EU 10kw split air to water heat pump R32 EVI low temperature heat pump
- Monobloc A+++ EU High COP air to water heat pump EVI Full DC Inverter cooling heating DHW heat pump
- Europe customized R32 A+++ heat pump 8kw 10kw 15kw 18kw 25kw 30kw split heat pump price
- Split Type Air Water Heat Pumps Heating DHW Cooling Model A+++ high scop European Union heat pumps price
- monoblock heat pump Air water EU France poland Czech Republic Bulgaria Finland Switzerland Netherlands
- DC INVERTER AIR TO WATER HEAT PUMP
- DC INVERTER SPLIT TYPE HEAT PUMP,Heating capacity,9kw
- DC INVERTER SPLIT TYPE HEAT PUMP,Heating Capacity,15kw
- Dc Inverter Split Type Heat Pump,15kw,
- DC INVERTER SPLIT TYPE HEAT PUMP,Heating Capacity,18kw
- DC INVERTER SPLIT TYPE HEAT PUMP,Heating Capacity,20kw
- Rated Current Input Without E-heater (a),20 Dc Inverter Monoblock Type Heat Pump
- Rated Current Input Without E-heater (a),24 Dc Inverter Monoblock Type Heat Pump
- Rated Current Input Without E-heater (A),30 DC INVERTER MONOBLOCK TYPE HEAT PUMP
- 100l Single Or Double Coils Stainless Steel Insulated 304/316 Vented Hot Water Tank Water Heater Boiler For House And Villas
- 200 Liter Single Double Coil Instant Electric Water Heater With Pump Dhw Buffer Underfloor Heating And Domestic Hot Water Tank
- Energy Shortage Alternative CE ERP certificate 160L boiler dhw tank hotwater tank heat pump electric tankless water heater
- 25L 30L 50L 60L 80L 120L Subsidie warmtepomp belgie hot water boiler r290 r744 Lucht-waterwarmtepompen house buffer water heater tank
- 100-1000 Liter Subsidie warmtepomp belgie hot water boiler r290 r744 Lucht-waterwarmtepompen house water heater tank
- Solve Coal Deficit 300L domestic multiple heat source support pompa ciepla heat pump geothermal hot water tank
- 200L House Hotel Villas School Heat Pump Air To Water 12kw Electric Thermostatic Instantaneous Domestic Hot Water Storage Tank
Popular Searches
- hotel equipment
- Heatpump Water Heater
- Swimming Pool Water Heater
- Air Heater
- Heat Pump Water Heaters
- air source water heater
- swimming pool heater
- Heat Pump House Heater
- hot water heater project
- sauna heater
- household heat pumps air water
- air heating pump
- air water heater
- air water heating pump
- Air To Water Heatpump
- Air Source Heatpump
Recommended Products
Find Similar Products By Category
- Home Appliances > Water Heaters > Heat Pump Water Heaters
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Junji Zhang
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-