Place of Origin | Hunan, China | Brand Name | ZHONGPU SHENGDE | |
Model Number | DXH06-F/3DC800R40 |
Product Description
1. APPLICATION
Designed especially for surge protection of the PV strings; apply to the PV power grid-connection system.
2.TECHNICALS PARAMETERS
Model DXH06-F/ | 3DC1000R40 | 3DC800R40 | 3DC600R40 | |
Type (IEC 61643-1) | Class II /Type 2 | |||
Max. Continuous Operating Voltage(Uc) | 1300VDC | 1000VDC | 800VDC | |
Nominal Continuous Operating Voltage(Un) | 1000VDC | 800VDC | 600VDC | |
Nominal Discharge Current Capacity (In) | 20kA(8/20μs) | |||
Max. Discharge Current Capacity (Imax) | 40kA(8/20μs) | |||
Protection Mode | Full Mode Protection | |||
Protection Level(Up) | ≤4.0kv | ≤3.6kv | ≤3.2kv | |
Response Time(T) | <25ns | |||
Fault Indicator | Available | |||
Live Line(mm² ) | ≥6 | |||
Earth line(mm² ) | ≥10 | |||
Grounding Resistance(R) | ≤4Ω | |||
Protection Level of the Shell | IP20 | |||
Operating Temperature | -40℃~+70℃ | |||
Overall Size(mm) | 54×90×65 | |||
Installation Method | 35 mm DIN-rail |
3.NAMING RULES:
4. WIRING DIAGRAM
5.Main Features:
l Use Y-shaped connection, Full mode protection of the L+-L-/PE;
l Use the temperature control circuit break protection technology,to avoid the accident;
l With the remote alarm contact signal, convenient to remote monitoring of the system;
l The module has normal and fault indication, with fast response speed and low residual voltage.
6.Installation Method and Attentions
1) Wiring as shown in Figure;
2) The connecting lead shall use many strands of copper wires of more than 6mm2, and the earth wire shall use many strands of copper wires of more than 10mm2. The connecting wire shall be as short, straight and coarse as possible. Grounding Resistance should be no less than 4Ω;
3) The front of lightning arrester shall be connected with proper fuse in series or be opened;
4) The power supply must be cut off while conducting the installation. It is prohibited to conduct the operation with the charge. The connecting lead must conform to the requirement;
5) After completing the installation, the lightning protection module shall be inserted tightly and inspected;
6) When there is RED for the fault indicator of the lightning arrester module (warning signal of remote-signaling port), it indicates that the lightning protection module has degraded and shall be replaced;
7) The SPD needn't special maintenance, but only check the connection and indicating state periodically.
7. Certificates:
Contact Us
- Hunan Zhongpu Lightning Protection Co., Ltd.
- Contact nameDerain Tan Chat Now
- Phone86-0731-22461398
- AddressBldg 5, SME Promotion Park, Zhuzhou, Hunan
Product Categories
DC Surge Protection Device | Lightning Protection Socket | New Products | Photovoltaic Surge Protection Device |
Signal Surge Protection Device | Wind Power Generation Surge Protection Device |
New Products
-
24V Combined 3 in 1 Signal Lightning Surge Protector
-
24V Combined 3 in 1 Signal Under Voltage Protector
-
24V Combined 3 in 1 Signal Lightning Arrester
-
24V Combined 3 in 1 Signal Lightning Protection Device
-
220V Signal Lightning Protector
-
Network Surge Protection Device
-
50kA 10/350us CLASS I Wind Power Generation Lightning Surge Protector
-
50kA 10/350us CLASS I Wind Power Generation Surge Protection Device
-
50kA 10/350us CLASS I Wind Power Generation Surge Arrester
-
50kA 10/350us CLASS I Wind Power Generation SPD
-
50kA 10/350us CLASS I Wind Power Generation Lightning Protection Device
-
50kA 10/350us CLASS I Wind Power Generation AC Surge Protector
-
50kA 10/350us CLASS I Wind Power Generation 440V Surge Protector
-
50kA 10/350us CLASS I Wind Power Generation Lightning Arrester
-
50kA 10/350us CLASS I Wind Power Generation Under Voltage Protector
-
50kA 10/350us CLASS I Wind Power Generation Surge Protector
-
50kA 10/350us CLASS I Wind Power Generation Lightning Protection
-
Class II N-PE Wind Power Generation Surge Protection Device
-
Class II N-PE Wind Power Generation Outdoor Surge Protector
-
Class II N-PE Wind Power Generation AC Surge Protector
-
Class II N-PE Wind Power Generation 690V Surge Protector
-
Class II N-PE Wind Power Generation Surge Protector
-
Class II N-PE Wind Power Generation Lightning Arrester
-
Class II N-PE Wind Power Generation Lightning Protection
Popular Searches
- power transformer
- Distribution Service
- current transformer
- power transformers
- High Frequency Transformer
- Electrical Transformer
- energy saver device
- led transformers
- step up converter
- Ac Drive Converter
- Frequency Drive Converter
- lightning conductor
- Copper Lightning Rod
- electronic transformer
- Lighting Transformers
- toroidal transformer
- auto transformer
- current transformer inductor
- voltage transformer
- Control Transformer
- Power Supply Transformer
- Led Lighting Transformer
- Waterproof Transformer
- Electric Transformer
- Low Frequency Transformer
- Flyback Transformer
- Core Transformer
- pot & kettle
- Output Inductor
- Power Distribution Equipment
Recommended Products
- ABB ICSF08D1 FPR3323101R1012
- Allen Bradley 2080-LC20-20QWB
- Allen Bradley 1606-XLB480E
- Honeywell DC-TAIX11
- Schneider Electric 140CPU31110
- Emerson PR6423/00R-010-CN CON021/913-030
- ABB 3BHE024747R0101 GDC801A101
- ABB HIEE300900R0001 PPC322 BE
- Bently Nevada 330104-00-16-10-11-00
- ABB SDCS-CON-4 3ADT313900R1501
- Honeywell 51451326-504
- Bently Nevada 330500-00-00
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Derain Tan
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile