Home > Electrical & Electronics > Optical Fiber, Cable & Wire > Electric Wire & Cable > ACSR 50mm2 Aluminum Conductor Steel Reinforced Rabbit

ACSR 50mm2 Aluminum Conductor Steel Reinforced Rabbit

ACSR 50mm2 Aluminum Conductor Steel Reinforced Rabbit photo-1
US$ 0.0001 - 10 MOQ: 1000 Meters
Key Specifications
Get Latest Price
Place of Origin:
Henan, China
Brand Name:
SAN HENG
Model Number:
acsr
Payment & Shipping
Payment Methods:
Port of Shipment:
Qingdao CHINA
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Henan, China
Brand Name SAN HENG
Model Number acsr
Insulation Material Other, Bare
Type High Voltage
Application Overhead
Conductor Material Aluminum
Jacket Other, NONE

Specifications

ACSR 50mm2 aluminum conductor steel reinforced rabbit
1.more than 15-year experience
2.Factory price&best quality

  

  ACSR 50mm2 aluminum conductor steel reinforced rabbit

 

ACSR (Aluminum Conductor Steel Reinforced)

APPLICATIONS:

Used as bare overhead transmission cable and as primary and secondary distribution Cable. ACSR offers optimal strangth for lin designing. Variable steel core stranding for desired strength to be achieved without sacrificing ampacity.

CONSTRUCTION:

Aluminum 1350-H19 wires, concentrically stranded around a steel core. Core wire for ACSR is available with class A, B or C galvanizing ;Aluminum coated( AZ) or aluminum-clad steel core (AL). Aditional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.

 

ACSR & AAC Conductor Wire (Aluminum Conduct Steel Reinforced)   is widely used in the overhead power distribution system of our country.

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, ASTM B232, CSA C49, DIN48204, JIS C3110, customer special specification also can be satisfied.
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power
Applications
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Construction
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.

Specifications
ACSR bare conductor meets or exceeds the following ASTM specifications:

B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Notes
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
The data sheets below show part spec of IEC61089

Code Number Stranding&Wire Diameter Approx Sectional Area ApproxWeight Breaking Load DC Resistance
Overall
Al Steel Diameter Al Steel Total
mm mm mm mm 2 mm 2 mm 2 Kg/km KN Ohm/km
16 6/1.84 1/1.84 5.53 16 2.67 18.7 64.6 6.08 1.7934
25 6/2.30 1/2.30 6.91 25 4.17 29.2 100.9 9.13 1.1478
100 6/4.61 1/4.61 13.8 100 16.7 117 403.8 34.33 0.2869
125 18/2.97 1/2.97 14.9 125 6.94 132 397.9 29.17 0.2304
160 18/3.36 1/3.36 16.8 160 8.89 169 509.3 36.18 0.18
250 22/3.80 7/2.11 21.6 250 24.6 275 880.6 68.72 0.1154
400 54/3.07 7/3.07 27.6 400 51.9 452 1510.3 123.04 0.0723
450 54/3.26 7/3.26 29.3 450 58.3 508 1699.1 138.42 0.0643
500 54/3.43 7/3.43 30.9 500 64.8 565 1887.9 153.8 0.0578
560 54/3.63 19/2.18 32.7 560 70.9 631 2103.4 172.59 0.0516
630 54/3.85 19/2.31 34.7 630 79.8 710 2366.3 191.77 0.0459
710 54/4.09 19/2.45 36.8 710 89.9 800 2666.8 216.12 0.0407
800 72/3.76 7/2.51 37.6 800 34.6 835 2480.2 167.41 0.0361
900 72/3.99 7/2.66 39.9 900 39.9 939 2790.2 188.33 0.0321


ACSR 50mm2 aluminum conductor steel reinforced rabbitACSR 50mm2 aluminum conductor steel reinforced rabbitACSR 50mm2 aluminum conductor steel reinforced rabbitACSR 50mm2 aluminum conductor steel reinforced rabbit







 

 

 

 

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2000
Factory Size
5,000-10,000 square meters
Total Employees
51 - 100 People