WGZ-2000/2000P/4000/4000P Turbidity Meter With the Best Price
High Quality WGZ-2000/2000P/4000/4000P turbidity meter with the best price
Summary
WGZ Series scattered light turbidity meter is used for measuring the scattering degree of the lights
generated by the insoluble grain matters suspended in water or transparent liquids, with capability to
characterize the content of these suspended grain matters.
It can be broadly applied in the measurement of turbidity in power plants, waterworks, treatment stations
of domestic sewage, beverage factories, environmental protection departments, industrial water, wine and
pharmacy industries, epidemic prevention divisions, hospitals, and etc.
Applications
*Microcomputer, touch keyboard, backlight LCD, standard parallel RS232 data communication interface
*Custom-made high strength long service life lamp-house, provided with data storage and inquiry function,
can meet GLP requirements
*Data nonlinear processing and data smoothing function, quick and automatic multi-points calibration,
self-diagnostic information prompt, selectable span ¨C automatic or manual switch
*Set average measuring mode with shortcut to obtain correct data within quickest time, applicable particularly
to measure extreme-low turbidity and can be used to measure unstable water sample
*Precise light route system, reliable positioning structure, effective tone compensation, direct turbidity
reading , built-in or external printer is optional
*Microcomputer, touch keyboard, backlight LCD, standard parallel RS232 data communication interface
*Custom-made high strength long service life lamp-house, provided with data storage and inquiry function,
can meet GLP requirements
*Data nonlinear processing and data smoothing function, quick and automatic multi-points calibration,
self-diagnostic information prompt, selectable span ¨C automatic or manual switch
*Set average measuring mode with shortcut to obtain correct data within quickest time, applicable particularly
to measure extreme-low turbidity and can be used to measure unstable water sample
*Precise light route system, reliable positioning structure, effective tone compensation, direct turbidity
reading , built-in or external printer is optional
Technical Specifications
Model |
WGZ-2000/2000P |
WGZ-4000/4000P |
Minimum Principle |
90º scattered light |
|
Minimum readout NTU |
0.01 |
0.001 |
Measuring range NTU |
0-10/0-100 0-1000/0-2000 |
0-10/0-100 0-1000/0-4000 |
Basic error F.S |
2%F.S/3%F.S/5%F.S |
|
Repeatability |
1% |
|
Zero draft NTU |
0.02 |
|
As one part of Chincan Sales Group, each factory has technical support staffs available offering repair and maintenance of the products exported by Chincan. We promise that all of our products will be easily accessible to technical support and manufacturer's representatives who are always ready and able to assist when needed.
Q: What after-sales service can be provided by CHINCAN ?
A: The after-sales service of CHINCAN is divided into two parts: technical support and maintenance.
Q: What about the technical support and maintenence?
A: Sometimes users will get some problems when they operate the instruments which are unfamiliar or first time use, users
can send us emails or call us about detailed information. We will provide users solution or operation video.For so many years’
experience, our instruments works well during warranty period. If there any parts are broken during warranty period, we would
like to provide spare parts for free.
Q: How to solve the disputes between CHINCAN and customers during the after-sales maintenance?
A: We will be customer oriented,and make concessions in some principles , we will properly handle the disputes to maximize
customer's satisfaction.
Normally all CHINCAN products are supplied with a warranty of 12 Months from the date of shipment. This warranty is entirely dependent on the following conditions:
1.The following circumstance don't belong to the warranty policy which is Man-made damages caused by improper operations.
2.The instruments must be operated in accordance with our operating guidelines; serviced and maintained on a regular basis
in accordance with the terms specified in the relevant user manual.
3. Only approved spare parts should be used in the instruments which bought from CHINCAN and these should be changed on
a regular basis as specified in the relevant user manual. Details of the approved spare parts and accessories for each
instrument are shown in the user manual or alternatively this information can be obtained from CHINCAN.
Send Inquiry to This Supplier
You May Also Like
-
High Quality WMP-5 Portable 5-parameters Water Quality DetectorUS$ 800 - 1,200MOQ: 1 Piece
-
High Quality SC-2 COD TesterUS$ 1,000 - 2,500MOQ: 1 Piece
-
WZH-1 Lab TurbidimeterUS$ 600 - 1,000MOQ: 1 Set
-
SC-2 COD TesterUS$ 1,000 - 2,500MOQ: 1 Set
-
HIGH PRECISE WZZ-2A Professional Polarimeter/High Quality Lab Polarimeter/Digital Automatic PolarimeterUS$ 1,100 - 1,200MOQ: 1 Set
-
HIGH PRECISE TDSscan10L Pocket TDS/Temp. Tester Quality ChoiceNegotiableMOQ: 10 Sets
-
HIGH PRECISE POL-200 Benchtop Semiautomatic Polarimeter With LED LightUS$ 100 - 1,000MOQ: 1 Set
-
HIGH PRECISE PHS-3BW Basic PH/mV/Temp. MeterUS$ 100 - 200MOQ: 1 Set
-
HIGH PRECISE DDS-12DW Benchtop Conductivity/Temp. Meter With the Best PriceUS$ 100 - 200MOQ: 10 Sets
-
HIGH PRECISE DDS-307W Benchtop Conductivity/Temp. MeterUS$ 100 - 200MOQ: 10 Sets