Home > Products > Laser Particle Size Analzyer > HE-NE Laser ultrasonic dispersion Winner2000ZD Zirconia particle size Analysis instrument
HE-NE Laser ultrasonic dispersion Winner2000ZD Zirconia particle size Analysis instrument
- 500 Set / Sets per Month
- Qingdao
- Credit Card PayPal
- High sensitivity China topseller Winner 2000ZDE Pesticide additives particle size analysis Instrument
- 30Years experience universal Winner2308C Charcoal Particle Size Analysis instrument
- Stable test China topseller Winner 2000ZDE coke powder particle size analysis Instrument
- Wet dispersion digital display control Economical small model Winner2000E Carbon particle size analysis instrument
- Double laser Multispectral probe Winner2008 Aluminum oxide particle size analysis instrument
- Double laser orthogonal optical bench Winner2005A Toner particle size analysis instruments
Product Details
Place of Origin: | Shandong, China | Brand Name: | Winner | Model Number: | Winner 2000ZDE |
Packaging Details
Wooden box outside, foam inside, prevent damage during the delivery.
Outer dimension is L105*W57*H54cm
Product Description
HE-NE Laser ultrasonic dispersion Winner2000ZD Zirconia particle size Analysis instrument
Winner 2000ZDE Laser particle size analyzer
is designed for the measurement of particles size distribution, which are extensively suited for any powder, grain and liquid materials ,such as the foodstuff ,chemical pharmaceutical, grinding, ceramic and metals processing ,especially in scientific laboratories and quality inspection departments.
Main Specification:
Model Name | Winner2000ZDE | Winner2000ZD(3 Gears) | |
Standard | ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009 | ||
Measuring Range | 0.1-300μm | 0.1-40μm /0.6-120μm/1-300μm | |
Channels Number | 39 | 32×3 | |
Accuracy | <1% (National Standard Sample D50 ) | ||
Repeatability | <1% (National Standard Sample D50 ) | ||
Light source | High performance He-Ne Laser (λ= 632.8nm, P>2MW) | ||
Dispersion Method | Ultrasonic | Frequency:40KHz Power:35W, Time: ≥1S | |
Stir | Revolutions Speed: 0-300RPM (Adjustable) | ||
Circulate | Rated Flow:8L/min Rated Power:10W | ||
Sample Pool | Volume:350mL | ||
Micro- Sample Pool | Volume: 10mL ( Available) | ||
Operation Mode | Full automatic and manual control, freely choose | ||
Optical Calibration System | Full automatic | ||
Test Speed | <2mins for each time | ||
Volume | L88cm×W39cm×H46cm | ||
Net Weight | 41Kg | ||
Warranty | 2 years |
Working Principle:
Main Features:
1, Intelligent operation mode realize one key test and decrease workload, Get better repeatability after remove human factors errors.
2, Optical Calibration System is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level,make optimum optical paths to ensure accurate and stable test.
3,Full built-in dispersion system, set mechanical stirring, ultrasonic dispersion, and circulation path in one, It ensures particles uniform dispersion and distribution,avoids many bad phenomenon, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube, And it guarantees the representativeness of test result.
4,Original Unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution.
5, Converging light Fourier transformation patent technology and gears test technology, which is not only overcomes limitation of lens aperture on scattering angle but also choose proper gear to test according the sample size distribution. It have high resolution and accuracy.
Accuracty is <1% (National Standard Sample D50 )
Repeatability is <1% (National Standard Sample D50 )
Patent Technology:
- Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
- Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
- Mie scattering principle application patent No.- ZL 2013 2 0812021.4.
- Dry particle size analyzer full sealed sample cuvette application is protected by patent No.- ZL.2011 2 0267646.8.
- Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0
- Powder dispersion pump design application is protected by patent No.-ZL 2007 2 0018648.7
- Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2
- Pressurized aerosol protection device for spray particle size analyzer is protected by patent No. ZL 2011 2 0267651.9
- Spray particle size analyzer with auxiliary probe construction is protected by patent No. ZL 2011 2 0267648.7
- Split spray laser particle size analyzer is protected by patent No. ZL 2011 2 0267654.2
Winner 2000ZDE particle testing equipment is Wooden box package, G.W.:50KG.
We would ship machine by DHL, FeDex, China express, by sea and by air.
Warranty: we will offer you free spare parts within 2 years, and technology support in all a life.
After warranty time, we will offer them at cost price, and shipping cost would be paid by customers.
24 Hours reply
7 Workdays offer solution
11 People-After sale service team
Jinan Winner Particle Instrument Co., Ltd. have been specialized in particle size analyzer for more than 20 years since that we take National science Project-particle size analyzer development in 1985.
High quality assurance is our task and also what we are doing now.
1. How about the package ? Is it safe during the delivery ?
All Particle size analyzer is packed by standard strong wooden carton with foam inside.
It is safe when shipping.
2. What is the delivery way ? How many days will the machine arrive us ?
We will ship the particle size analyzer by DHL,FedEx, UPS,etc (Door to Door Service), around 5 days to arrive.
Or by Air to your airport (Door to Airport Service ), around 3 days to arrive.
Or by Sea to the seaport, Minium CBM requirement : 1 CBM, around 30days to arrive.
3. Do you provide the Warranty ? How about the after sales service ?
2 year warranty free for spare parts, Whole life technical support.
We have professional after sales team, if any question, assistant videos are also provided in after-sale service.
4, This machine is easy to use ? if I have no experience, I can also operate it well ?
Do you provide the user manual and operating videos to support us ?
Yes, our particle size analyzer is designed to use easily, computer control. Normally it will take you 2-3 hours to learn how to operate, if you are a technician, it will much faster to learn.
We will provide the English user manual for free , and the operation video is available.
5, If we come to your factory, if you will provide the free training ?
Yes, warmly welcome you to visit our factory, we will arrange the free training for you.
6. What is the payment way ?
We accept the payment terms: Bank transfer, Western union, Money gram, Paypal, etc.
If any question, you can send INQUIRY , or CHAT with us, we will be glad to service you !
Company Profile
Jinan Winner Particle Instrument Co., Ltd. have have been specialized in particle size analyzer for more than 20 years, since we undertake National Science Project-particle size analyzer development in 1985.
We are the 1st manufacturer to produce Nano-particle size analyzer in China!
Our particle size analyzer will enable you understand materials well, and save your time and cost. Reliable data enables scientists, researchers and engineers to evolve formulations and processes with confidence. Our products guide research and product development, manage and control manufacturing quality, and optimize output.
By now, We have Laser Particle size analyzer, Image particle size analyzer, Spray particle size analyzer, particles counter and Nano-particles size analyzer and so on.
We are dedicated to offer you the best particle size analysis solution.
Your satisfaction is our eternal target!
Contact Us
- Jinan Winner Particle Instruments Co., Ltd.
- Contact nameCathy Feng
- Phone86-531-88873319
- AddressUnit 2, East Building F, North Area, 750 Shunhua Road, Gaoxin District
Dry particle size analyzer | Image Particle Size Analyzer | Laser Particle Size Analzyer | Nanoparticle Size Analyzer |
New Products | Spray Particle Size Analyzer | Wet Particle Size Analyzer |
- Wholesaler Winner 802 highly accurate semiconductor fiber laser nano metallic oxide particle size analyzer
- Winner 802 nano coating laser particle size analyzer
- Jinan Winner 802 nanometer ceramics Dynamic light particle size analyzer
- Jinan Winner 802 nanoparticle measurement particle size analyzer with Digital correlator
- Jinan Winner 802 dynamic light scattering nanoparticles particle size analyzer
- Jinan Winner 802 nanoparticles particle size analyzer
- Jinan Winner 802 online nano particle size analyzer for testing coating paint powders
- Jinan Winner 802 nano particle size analyzer for testing coating paint powders
- Jinan Winner 802 dynamic light nanoMagnesium Oxide particle size instrument
- Jinan Winner 802 dynamic light scattering nanoparticle size analyzer with high speed digital Correlator
- Jinan Winner 802 nanoparticle Powder particle size analyzer for oil emulsion
- Jinan Winner 802 nanoparticle Powder particle size measurement instrument for polymer latex
- Winner 802 laser diffraction Nano emulsion particle size analyzer for research institute
- Winner 802 Nano coating particle size analyzer for lab equipment
- Winner 802 Nanometer particle size distribution analyzer with Japan PMT
- Winner 802 Nanometer particle size distribution measurement instrument based on Brownian motion
- Winner 802 Nano particle size analysis instrument D10 D50 D90 for testing micron size
- Winner 802 Nano Laser Diffraction Particle Size Analyzer for test Nano aluminum powder
- Winner 802 dynamic light nanotrack particle size analyzer for measuring bentonite particles
- Winner 802 good accuracy nano particle size analyzers for testing plaster
- Winner 802 dynamic light scaterring nanometer laser particle size analyzer for nano Barium titanate particle test
- Winner 802 nanometer Vitamins test particle size analyzer for lab instrument
- Winner 802 dynamic light scaterring nanometer laser particle size analyzer for nano metllic oxide size distribution test
- Winner 802 dynamic light scaterring Nano-catalytic additive lubricants particle size analyzer
Recommended Products
- Acrel ADF400L-3D 3 circuits single phase 10(80)A High accuracy
- Acrel ADF400L-4H Multi Circuit Electrical Instruments 4 channel 3 phase 3*1(6)A High installation flexibility
- Acrel Multi Circuit Electrical Instruments 2 channel 3 phase 3*10(80)A ADF400L-2S din rail
- Acrel din rail Multi Circuit Electrical Instruments 6 channel single phase 10(80)A High installation flexibility ADF400L-6D
- Acrel 6 channel three phase 3*1(6)A High installation flexibility din rail ADF400L-6H Multi Circuit Electrical Instruments
- Acrel current transmitter input AC 0-1/5A output 4-20mA power AC/DC 85-270V BD-AI
- Acrel Active power transmitter AC/DC85-270V 1 Channel analog output BD-3P
- Acrel BD-4E Multi-power digital transmitter 2 channels energy impulse output Rs485 modbus-RTU
- Acrel BD-4EA transmitter 2 channels energy impulse output Rs485 modbus-RTU Multi-power digital
- Acrel transmitter AC/DC85-270V 1 Channel analog output 4-20mA BD-4P Active powe
- Used Temperature And Humidity Test Chamber High And Low Temperature Test Chamber Climate Aging Testing Machine
- JINGYAN Low Temperature Test Chamber Constant Temperature And Humidity Machine Environmental Aging Test Chamber
Find Similar Products By Category
- Measurement & Analysis Instruments > Analyzers > Other Analysis Instruments
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Cathy Feng
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-