MPPT SOLAR CHARGE CONTROLLER
BUILT-IN MPPT TRACKER FOR OPTIMIZING THE POWER TRANSFORMATION.

solar charge controller
Features 

High converting efficiency higher than 97% for minimizing energy loss

  • Build-in MPPT tracker for optimizing the power transformation
  • Reversed current protection for preventing equipment damage
  • Automatic battery temperature compensation for long-term reliability
  • Capable of selecting different charging mode for various type of batteries
  • Capable of connecting additional DC load for wider applications
  • Three stage charge control system (bulk, absorption, and float mode) with temperature compensation
  • LED indicators display charge status in real time
  • Pulse Width Modulation (PWM) topology combined with a multi-stage charge control algorithm leads to superior charging and enhanced battery performance

MODEL

SMS-40A

Rated Voltage

12/24 VDC

Rated charge current

40A

Load current

15A

Input voltage range

15-55VDC

Max. PV open circuit array voltage

55VDC

Typical idle consumption

At idle < 10mA

Overload protection (DC load)

2.0*Inom>5s

1.5*Inom >20s

1.25*Inom temperature controlled

Bulk charge

14.6V(default)

29.2V(default)

Floating charge

13.4V(default)

26.8V(default)

Equalization charge

14.0V(default)

28.0V(default)

Over charge disconnection

14.8V

29.6V

Over charge recovery

13.6V

27.2V

Over discharge disconnection

10.8 V (default)

21.6V(default)

Over discharge reconnection

12.3V

24.6V

Temperature compensation

-13.2mV/°C

-26.4mV/°C

Lead acid battery settings

Adjustable

NiCad battery settings

Adjustable

Load control mode

  1. Low Voltage Reconnect (LVR): Adjustable

2. Low Voltage Disconnect (LVD): Automatic disconnection

3. Reconnection: Includes warning flash before disconnect and reconnection

Low voltage reconnect

12.0-14.0 Vdc

24.0-28.0 Vdc

Low voltage disconnect

10.5-12.5 Vdc

21.0-25.0 Vdc

Ambient temperature

0-40°C(full load)  40-60°C(de-rating)

Altitude

Operating 5000 m, Non-Operating 16000 m

Protection class

IP21

Battery temperature sensor

BTS - optional remote battery temperature sensor for increased charging precision

Terminal size (fine/single wire)

#8 AWG

 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2008
Factory Size
10,000-30,000 square meters
Total Employees
101 - 200 People

Recommended Categories

Explore top categories and find suppliers for your specific needs