Home > Electrical & Electronics > Sensor > Pressure Sensor > CNG/LPG Differential Pressure Sensor Module

CNG/LPG Differential Pressure Sensor Module

CNG/LPG Differential Pressure Sensor Module photo-1
Negotiable MOQ: 1000 Pieces (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Place of Origin:
Shanghai, China
Brand Name:
SEMORE
Model Number:
SOP8-Q
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Shanghai, China
Brand Name SEMORE
Model Number SOP8-Q
Usage Pressure Sensor
Theory Resistance Sensor
Output Analog Sensor
  • 1.5% Maximum Error Over 0 to 85°c
  • Temperature Compensated Over -40 to +125 °c
  • Small Size
  • High reliability, low drift 

 

SOP8-Q Pressure Sensor is consists of SOP8 packaged pressure sensor and signal conditioning circuit. The pressure sensor systems mounted on a 11.6*13.6mm FR4 PCB. The SOP8-Q Pressure Sensor has the features of the small form factor and high reliability. The pressure range of the sensor cell is 0~2000KPa absolute pressure. The supply voltage is 5 ± 0.5V,the type supply current is 2.0mA, the output is 0~5V.

The relationship between input and output can customize the characteristics design according to the requirements of the costumer.

 

  

Applications                       


  • Automotive Pressure Monitoring
  • Pneumatic Gages
  •  Hand-held Meters 

Pin Configuration                     


1) Pressure sensor side                       2) Sensor Signal Conditioner side 

 

 

3) Lateral side

 

 

 

 

Operating Characteristics

Table 1. Operating Characteristics (VS=5.0Vdc, TA=25 °c )

Characteristic

Symbol

Min

Typ

Max

Unit

Supply Voltage

Vs

4.5

5

5.5

V

Supply Current

Io

 

1.8

3

mV

Accuracy 

(0 to 85 °c )

 

 

 

1.5%

%FS

Response Time 2

TR

 

1.0

 

mS

Warm-Up Time 3

 

 

10

 

mS

Offset Stability 4

 

 

±0.5

 

%FS

Power ON Rise Time

Tpon

 

 

100

mS

 

 

  1. Device is ratiometric within this specified excitation range.
  2. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to a specified step change in pressure.
  3. Warm-up Time is defined as the time required for the product to meet the specified output voltage after the Pressure has been stabilized.
  4. Offset Stability is the products output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.

 

 

Typical Application Circuit                  

 

 

 

 

 

 

 

 

 

 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Year Established
2015
Factory Size
Below 1,000 square meters
Total Employees
11 - 50 People