Home > Industrial Equipment & Components > Power & Generating Sets > Diesel Generator > Factory Directly ! Single Phase Alternator Used for Diesel Generator ST Series

Factory Directly ! Single Phase Alternator Used for Diesel Generator ST Series

Factory Directly ! Single Phase Alternator Used for Diesel Generator ST Series photo-1
US$ 30 - 800 MOQ: 5 Pieces
Key Specifications
Get Latest Price
Place of Origin:
Fujian, China
Brand Name:
DELLENT
Model Number:
ST Series
Payment & Shipping
Payment Methods:
Port of Shipment:
Fuzhou China
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Fujian, China
Brand Name DELLENT
Model Number ST Series
Output Type AC Single Phase
Speed 1500RPM ,1800RPM
Frequency 50HZ ,60HZ
Rated Power 1KW to 24KW
Rated Voltage 220V ,230V
Rated Current 4.35A --104A

Specifications

Single phase alternator used for diesel generator ST series
1, 100% copper
2, factory directly
3, ISO CE SGS CQC
4, reliabel

Factory Directly !  single phase alternator used for diesel generator ST series

 
Product Description

 

The ST series generators are mainly designed to serve as power generating unit of small capacity, which supply electricity for lighting purpose in ships, for house-hold electric devices used in towns or villages.
The construction of the generators is of drip-proof, salient pole rotating field self excitation and constant voltage type. The alternator interior is used with high quality electric magnetic and Electric materials. Stator insulation is class B. These generators are elegant in appearance, tight in construction and easy maintenance. IEC standard are adopted on dimension, these dimension are suitable for using in Australia, Europe, America and other countries with the end covers to be model B.
These generators are excellent in appearance and easy to maintain. Dimensions are adopted according to I.E.C Standards, the alternator is 230V of 115V, the frequency is 50Hz. Its operation mode is of continuous duty. It can provide 60Hz and the other voltage's generator according to necessary.
Operating Conditions:         
1. Altitude: not exceed 1000m.           
2. Cooling air temperature: 258~313K (-15 °C ~40 °C ).
3. Relative air humidity: not exceed 90%.    
The alternators are of harmonic wave self-exciation constant voltage system and automatic voltage control excitation constant voltage system, both of them have Excellent dynamic performance, convenient and reliable in operation. These generators are excellent in appearance and easy to maintain. Dimensions are adopted according to I.E.C Standards.
The voltage of the alternator is 230V of 115V, the frequency is 50Hz. Its operation mode is of continuous duty. It can provide 60Hz and the other voltage's generator according to necessary.
The other voltage's generator according to necessary.
The alternator can be coupled with a prime mover directly or through a V-belt, with 5% change of speed of the prime mover under load Variation of 0~100%, at a voltage of 230V or 115V, 50Hz or 60Hz to get a satisfactory constant voltage performance.

 

ST Alternator Specification

 

Model Output Current(A) Voltage(V) Power factor Pole Speed 
(kW) Series Connection Parallel Connecion Series Connection Parallel Connection (cos) number (r.p.m)
ST-1 1 4.35 8.7 230 115 1 4 1500
ST-2 2 8.7 17.4 230 115 1 4 1500
ST-3 3 13 26 230 115 1 4 1500
ST-5 5 21.8 43.5 230 115 1 4 1500
ST-7.5 7.5 32.6 65.2 230 115 1 4 1500
ST-10 10 43.5 87 230 115 1 4 1500
ST-12 12 52.2 104 230 115 1 4 1500
ST-15 15 65.3 130 230 115 1 4 1500
ST-20 20 87 174 230 115 1 4 1500
ST-24 24 104 208 230 115 1 4 1500
 
WHY CHOOSE US (OUR ADVANTAGE)
WHAT WE DO AT DELLENT
• Having self-own plants producing for stators ,rotors and some related die-casting parts since from 1995
• Stamping of lamination
• Rotor die-casting
• Winding and inserting – both manual and semi-automatically
• Vacuum varnishing
• Machining shaft, housing, end shields, etc…
• Rotor balancing
• Painting – both wet paint and powder coating
• Assembling
• Packing
• Inspecting spare parts every processing
• 100% test after each process and final test before packing. 

 

WHAT DELLENT CAN DO FOR CUSTOMERS

• Dellent supplies standard products to customers.
• Dellent supplies standard products under customers’ brands and packaging, etc
• Dellent develops any new products together with the customers.

 

 
Company View

Factory Directly ! single phase alternator used for diesel generator ST seriesFactory Directly ! single phase alternator used for diesel generator ST seriesFactory Directly ! single phase alternator used for diesel generator ST seriesFactory Directly ! single phase alternator used for diesel generator ST seriesFactory Directly ! single phase alternator used for diesel generator ST seriesFactory Directly ! single phase alternator used for diesel generator ST seriesFactory Directly ! single phase alternator used for diesel generator ST seriesFactory Directly ! single phase alternator used for diesel generator ST seriesFactory Directly ! single phase alternator used for diesel generator ST series

 
DELLETN PRODUCTS PACKING

 

 

                       CERTIFICATION

/ http://dellent-motor.en.china.cn
Factory Directly ! single phase alternator used for diesel generator ST seriesFactory Directly ! single phase alternator used for diesel generator ST series
 
  Factory Directly ! single phase alternator used for diesel generator ST series
 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer
Year Established
2010
Factory Size
5,000-10,000 square meters
Total Employees
11 - 50 People

Recommended Categories

Explore top categories and find suppliers for your specific needs