dc Air Conditioner for Telecom Cabinet
Detailed Product Description

Cabinet Air Conditioner YX-FK Series

——Introduction for the products
The cabinet air conditioner refrigerates the air through inside and outside two independences, and exchanges the heat inside the cabinet to the outside by the heat -exchanger. By this way, it can protect the electricity wind chest's electrical element in the controllable temperature range movement. Simultaneously the cabinet air conditioner has dehumidifies the function, which will guaranteed the cabinet interior has the ideal temperature and the humidity.
Fengtely is popular of varies of the Cabinet Air Conditioners in the national market, which can meet the demand of the consumers.
Type |
refrigerating output(BTU/h) |
voltage/ electric current/ rated power |
Size(mm) |
weight (kg) |
||
width |
height |
deep |
||||
YX-FK340-W |
1230 |
230VAC/50Hz/1.3A/235W |
370 |
540 |
215 |
25 |
YX-FK1100-W |
4000 |
230VAC/50Hz/3.3A/390W |
470 |
1170 |
275 |
62 |
YX-FK2000-W |
7200 |
230VAC/50Hz/4.5A/720W |
470 |
1170 |
350 |
78 |
note: | ||||||
adjustable temperature range |
28°C-50°C |
|||||
refrigerating fluid |
R134a |
|||||
Application Environment |
≤60°C |
|||||
FK series of standard indoor cabinet air conditioner:
- Installation Instructions

(F K 3 4 0-site physical map)
- Side-mounted air-conditioning installation steps:
1. Installed in accordance with the corresponding models of air conditioning openings Figure a good hole in the cabinet side or on the door (Note: the side-mounted air-conditioning depends on the cabinet to install the upper, must ensure that the open hole is horizontal, because the air conditioning requirements, it is best tohorizontally mounted)
2. The air conditioner fixed in the cabinet has been opened good holes, screws;
3. comes with air conditioning drain installed Fortunately, air-conditioning at the bottom of, and connect the supplied hose
4.The power cord from the professionals, and open the air conditioning panel switch, air conditioning thermostat to display the cabinet temperature, circulation fan starts running at the same time within
5. air conditioning temperature setting (reference air conditioning random installation manual) air temperature factory setting is 3 3 ° C, under normal circumstances we do not recommend re-regulation, to avoid causing unnecessary trouble.



Picture of tapping:
Certification

Heat exchanger for communication cabinet:
Send Inquiry to This Supplier
You May Also Like
-
Fiberglass Reinforced Plastic Air Ducts, Inorganic Fiberglass Reinforced Plastic Air Channels, Organic Fiberglass Reinforced Plastic Ventilation DuctsUS$ 24.62 - 27.69MOQ: 1 Meter
-
4-way Cassette Fan Coil UnitNegotiableMOQ: 1 Piece
-
Water Cooled Air Conditoner( Air Volume M3/h 14000-25000)NegotiableMOQ: 2 Sets
-
Industrial Air Conditioner and Air Conditioning System Manufacturer in ChinaNegotiableMOQ: 10 Sets
-
Industrial Air ConditionerNegotiableMOQ: 2400 Sets
-
APP Control Mist Free Humidifier,0 Fog Ultrasonic Humidifier,Evaporative Humidifier/demineralizerNegotiableMOQ: 1000 Pieces
-
Cutting Tools Kit With Aluminum Carrying Case For Phenolic Foam Insulation Sheet Board Duct Good PriceNegotiableMOQ: 1
-
Small Steel Hatch Cover Easily Operating Experienced ManufacturerUS$ 0.5 - 11.9MOQ: 500 Pieces
-
ISO Standard Container Ventilator Hood ManufacturerUS$ 1 - 3.5MOQ: 500 Pieces
-
Class 100 Cleaniness FFU With Low Noise for Ultra-clean SpaceUS$ 1 - 1MOQ: 1 Set