Home > Industrial Equipment & Components > Ventilation Equipment > Ventilation Fan > HTF Fire-control Fan, Axial Fan, Jet Fan for Extraction Smoke

HTF Fire-control Fan, Axial Fan, Jet Fan for Extraction Smoke

HTF Fire-control Fan, Axial Fan, Jet Fan for Extraction Smoke photo-1
HTF Fire-control Fan, Axial Fan, Jet Fan for Extraction Smoke photo-2
HTF Fire-control Fan, Axial Fan, Jet Fan for Extraction Smoke photo-3
Negotiable MOQ: 50 Volts (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Electric Current Type:
AC
Blade Material:
Cast Iron
Mounting:
Duct Fan
Payment & Shipping
Payment Methods:
Port of Shipment:
Foshan
Delivery Detail:
Delivery time depends on order quantity.
Electric Current Type AC
Blade Material Cast Iron
Mounting Duct Fan
Place of Origin Guangdong, China
Brand Name Popula
Model Number HTF(A)-I
Power 1.5` 22kw
Voltage 220/380V
Air Volume 76041~93800CMH
Speed 720/960/1400/1450/1470/2800/2900RPM
Certification CCC

Specifications

 

HTF Fire-control Fan for Extraction Smoke(axial fan) 
1 axial fan with large air volume 
2good performance,high efficiently 
HTF Fire-control Fan, axial fan, jet fan for Extraction SmokeHTF Fire-control Fan, axial fan, jet fan for Extraction Smoke

 

HTF Fire-control Fan for Extraction Smoke

HTF Fire-control Fan for Extraction Smoke is suitatble for fire control of tall buildings,subway tunnel,underground stores,gymnasia etc.This fan is set up with double-speed motor,it operates at a low speed normally and used for ventilation.Once occurrence a fire,the fan is automatically transferred into high-speed and discharge smoke by the electric control system,which facilitates safe evacuation of personnel on the fire spot.The transporting medium is air or other non-spontaneous-combution and non-explosive-combution air with no harm to human.The air transferred shall not contain any adhesive material,dust and grain and the concentration shall not exceed 150mg/m3 when the temperature shall not exceed 80oC.When used for fire control,the fans can run more than 30 minutes continually under the condition that the air and smoke temperature is at 280oC.

MODEL POWER(kW) ROTATION(r/min)  VOLUME(m3/h) PRESSURE(Pa) NOISE Db(A)
HTF-(A) SIGNLE SPEED SERIES      
4 1.5 2800 3800~5500 450~300 79
4.5 2.2 2800 6120~8500 670~410 84
5 3 2900 6817~9824 752~510 86
5.5 4 2900 10900~15200 900~530 86
6 5.5 2900 13197~16090 760~510 86
6.5 5.5 1450 15300~21500 680~425 86
7 7.5 1450 18908~24380 728~610 88
8 7.5 1450 26012~31421 723~600 89
9 11 1450 27613~33510 840~562 90
10 11 1450 35000~45679 770~630 90
11 15 1450 48500~51552 690~580 92
12 18.5 970 57748~62763 740~624 93
13 18.5 970 56031~74708 807~600 94
15 22 970 76041~93800 819~623 95
HTF-(A)-II DOUBLE SPEED SERIES  
5 3/2.4 2900 6817~9824 752~510 80
1450 3410~4912 188~127 75
6 5.5/4.5 2900 13197~16090 760~510 86
1450 6599~8045 190~127 75
7 8/6.5 1450 18908~24380 728~610 88
960 12518~16141 319~267 80
8 8/6.5 1450 26012~31421 723~600 89
960 17222~20800 317~263 80
9 11/9 1450 27613~33510 840~562 90
960 18216~22186 368~246 81
10 11/9 1450 35000~45679 770~630 90
960 24019~30255 338~276 80
11 16/13 1450 48500~51552 690~580 92
960 36375~38664 387~326 83
12 17/12 960 55651~62763 740~624 93
720 43311~47072 416~351 83
13 17/12 960 56031~74708 807~600 94
720 42023~56031 454~338 84
15 20/15 960 76041~93800 819~623 95
720 57031~70350 461~350 85

 

 

MODEL POWER(kW) ROTATION(r/min)  VOLUME(m3/h) PRESSURE(Pa) NOISE Db(A)
HTF-(B)-I DOUBLE SPEED SERIES  
3 2.2 2800 4070~5305 915~710 73
4 4 2900 5430~7860 1143~910 78
4.5 5.5 2900 5880~9520 1247~910 80
5 5.5 2900 7360~13000 1250~805 83
6 7.5 2900 15600~20840 916~776 85
7 11 1450 19680~25700 1018~878 82
8 15 1450 28320~37821 978~866 89
9 18.5 1450 36547~44398 978~895 90
10 22 1450 40750~54081 1134~949 91
11 30 1470 48530~60123 1128~870 92
12 30 980 46034~70231 1100~850 93
13 30 980 56845~89536 986~680 94
15 37 980 60438~116420 1150~650 95
HTF-(B)-II DOUBLE SPEED SERIES  
5 5.5/4.5 2900 7360~13000 1250~805 83
1450 3680~6500 313~201 75
6 11/9 2900 15600~20840 916~776 85
1450 7800~10420 229~194 76
7 11/9 1450 19680~25700 1018~878 82
960 13029~17015 644~385 73
8 16/13 1450 28320~37810 978~866 89
960 18750~25030 429~380 79
9 16/13 1450 36547~44398 978~895 90
960 24196~29395 429~392 80
10 28/22 1450 40750~54081 1134~949 91
960 26979~35805 479~415 81
11 28/22 1450 48530~60123 1128~870 92
960 36398~45092 494~381 82
12 30/15 960 46034~70231 1100~850 93
720 34526~52670 619~478 83
13 30/15 960 56845~89536 986~680 94
720 42637~67152 555~383 83
15 37/18 960 60743~116420 1150~650 95
720 45328~87315 647~366 87

 HTF Fire-control Fan, axial fan, jet fan for Extraction SmokeHTF Fire-control Fan, axial fan, jet fan for Extraction Smoke

...

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer
Year Established
2002
Factory Size
Above 100,000 square meters
Total Employees
Above 1000 People

Recommended Categories

Explore top categories and find suppliers for your specific needs