Home > Instruments & Meters > Electronic Instrument > Other Electronic Instruments > Complete Original Accessory Kit Keysight N5185A 4‑Channel RF Signal‑Generator for Laboratory R&D

Complete Original Accessory Kit Keysight N5185A 4‑Channel RF Signal‑Generator for Laboratory R&D

Complete Original Accessory Kit Keysight N5185A 4‑Channel RF Signal‑Generator for Laboratory R&D photo-1
Complete Original Accessory Kit Keysight N5185A 4‑Channel RF Signal‑Generator for Laboratory R&D photo-2
Complete Original Accessory Kit Keysight N5185A 4‑Channel RF Signal‑Generator for Laboratory R&D photo-3
Complete Original Accessory Kit Keysight N5185A 4‑Channel RF Signal‑Generator for Laboratory R&D photo-4
Complete Original Accessory Kit Keysight N5185A 4‑Channel RF Signal‑Generator for Laboratory R&D photo-5

Product Spotlights

Brand‑new original Keysight N5185A MXG X‑series compact multi‑channel analog signal generator is available from our spot inventory. It supports 1‑4 independent synchronous RF‑output channels, optional frequency‑coverage 9 kHz‑3 GHz /6 GHz /8.5 GHz. Every channel delivers maximum +25 dBm output power and‑146 dBc/Hz outstanding low phase‑noise. It achieves 800 μs fast frequency‑switching speed,‑96 dBc non‑harmonic spurious rejection and‑35 dBc harmonic suppression. The built‑in reflectometer imple
Negotiable MOQ: 1 Unit (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Warranty:
1 year
After-sales Service:
Online technical support
Brand:
Keysight
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
90 days
Warranty 1 year
After-sales Service Online technical support
Brand Keysight
Product Name Analog Signal Generator
Product Model N5185A-Option 508
Frequency range 9 kHz to 8.5 GHz
Power supply method Power supply
Packaging method Cardboard packaging
Transport Package Outer packaging
Specification Standard specifications
Trademark Keysight
Origin United States

Complete Original Accessory Kit Keysight N5185A 4‑Channel RF Signal‑Generator for Laboratory R&D


N5185A-Option 503:  9 kHz to 3GHz 

N5185A-Option 506:  9 kHz to 6 GHz 

N5185A-Option 508:  9 kHz to 8.5GHz 


Compact, multichannel analog signal generator with frequency coverage up to 8.5 GHz per channel



Highlights

Evolving technologies in wireless communications and aerospace and defense applications demand higher 

frequency coverage using complex modulation schemes like multiple-input / multiple-output (MIMO), 

beamforming, and multiplexing to maximize data throughput. The Keysight N5185A MXG analog signal 

generator provides consistent and repeatable results that are ideal for multiport testing. The MXG’s custom

DAC application-specific integrated circuits (ASICs) use direct digital synthesis to deliver precise signals in 

one easy-to-use box.


• Covers frequency range from 9 kHz to 8.5 GHz with excellent phase noise and output power.

• Supports military radio communications and MIMO tests with up to four unique outputs.

• Reduces measurement uncertainty in power amplifier characterizations when using the embedded reflectometer.

• Maximizes production capacity without sacrificing rack space in a 2U box.

• Enables fast access to a dedicated team of KeysightCare technical support engineers.




Definitions and Conditions 


Specifications represent warranted performance of a calibrated instrument that has been stored for a 

minimum of 2 hours within the operating temperature of 0 to 55 °C, unless otherwise stated, and after a 

45 minute warm-up period. The specifications include measurement uncertainty. Data represented in this 

document are specifications unless otherwise noted. 


Typical (typ) describes additional product performance information that is not covered by the product 

warranty. It is performance beyond specifications that 80 percent of the units exhibit with a 90 percent 

confidence level at room temperature (approximately 25 °C). Typical performance does not include 

measurement uncertainty. 


Nominal (nom) values indicate the expected mean or average performance, or an attribute whose 

performance is by design, such as the 50 ohm connector. This data is not warranted and is measured at 

room temperature (approximately 25 °C). 


Measured (meas) describes an attribute measured during the design phase for purposes of 

communicating expected performance, such as amplitude drift vs. time. This data is not warranted and is 

measured at room temperature (approximately 25 °C).



Options


Accessories

11900B:  Adapter 2.4 mm female to 2.4 mm female

11900C:  Adapter 2.4 mm male to 2.4 mm female

11901B:  Adapter 2.4 mm female to APC-3.5 female

11901C:  Adapter 2.4 mm male to APC-3.5 female

11904C:  Adapter 2.4 mm male to 2.92 mm female

83059B:  Coaxial Adapter, 3.5mm Female-Female

83059C:  Coaxial Adapter, 3.5mm Male-Female

Y1311A:  Additional removable M.2 drive

Y1310A:  Additional removable SD card

Y1313A:  Micro HDMI to Micro HDMI cable



WhatsApp:+85268839563

WeChat    :13728300615



N5185A (1)N5185A (5)N5185A (6)N5185A (4)N5185A (7)

Product Tags: N5185A signal‑generator , Keysight signal‑source , multi‑channel signal‑generator

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
1Yr
Verified Business License
Business Type
Trading Company
Year Established
2021
Factory Size
Below 1,000 square meters
Annual Export Value
Below US$1 Million

Recommended Categories

Explore top categories and find suppliers for your specific needs