Diesel Storage Microgrid System RPC3-S800KA230K-rp1 |
Product Overview
This system deeply integrates diesel power generation and intelligent energy storage, providing an efficient and stable off-grid/microgrid energy solution for high-standard engineering scenarios. The system achieves significant cost reduction and efficiency improvement through "using energy storage instead of diesel", supports flexible multi-mode operation, and provides all-weather reliable power support for application scenarios such as field construction, mining, and emergency support.
Product Advantages
Built-in battery performance detection and recording function: Supports real-time battery performance testing and data recording;
Highly integrated and pre-assembled design: Compact structure, significantly reducing the threshold for transportation and on-site deployment;
Supports flexible switching between three operation modes: Covers peak shaving and valley filling of the power grid, independent operation of the microgrid, and backup power supply for industry and commerce;
Multi-level battery protection and multi-dimensional fire protection system: Creates an all-round safety barrier to ensure the long-term reliable operation of the system;
Real-time status monitoring and fault recording: Has the ability of intelligent fault early warning and accurate positioning, improving operation and maintenance efficiency.
Product Features
Product Parameters
| Model | RPC3-S120KA241K-rp1 | RPC3-S233KA233K-rp1 | RPC3-S630KA322K-rp1 | RPC3-S756KA384K-rp1 |
| Full Capacity | 241kWh | 233kWh | 322kWh | 384kWh |
| Wiring Method | 3P4W+PE | |||
| Parallel Operation | Supported | |||
| Communication Interface | Ethernet/RS485/CAN | |||
| Altitude | 4000 (>2000m derating) | |||
| Operating environment temperature | -20℃~+55℃ (≥45℃ derating) | |||
| Allowable relative humidity | 5~95 (no condensation) | |||
| Temperature control scheme | Battery liquid cooling + Intelligent forced air cooling | Intelligent forced air cooling | ||
| Fire protection scheme | Aerosol + Perfluorohexanone | Perfluorohexanone | Heptafluoropropane | |
| Electrical protection | Overvoltage/undervoltage protection + Overload/short circuit protection + Surge protection + Anti-backflow protection | |||
| Protection level | Ethernet/ RS-485/CAN | |||
| Anti-corrosion level | C3 (optional) | |||
| External dimensions (mm) | 2000*2591*2438mm | 2500*2591*2438mm | 3658*2900*2438mm | 6366*2900*2438mm |
| Full configuration weight | 9t | 10t | 15t | 16t |
| DC Side Parameters | ||||
| Charge-discharge Rate | 0.5C Charge / 0.5C Discharge | 0.5C Charge / 1C Discharge | 0.5C Charge / 1C Discharge | 0.5C Charge / 1C Discharge |
| Cycle Life (@25℃, 70% EOL, 90% DOD) | 7000 cycles | 6000 cycles | 6000 cycles | 6000 cycles |
| PACK Capacity | 48.23kWh | 46.59kWh | 8.96kWh | 2.56kWh |
| DC Rated Voltage | 768V | 832V | 768V | 768V |
| DC Voltage Range | 660~864V | 715~936V | 660~864V | 660~864V |
| DC Current | 186A | 334A | 937A | 937A |
| Short Circuit Protection | MSD+Fuse | MSD+Fuse | Fuse | Fuse |
| AC Side Parameters | ||||
| Rated Capacity / Power | 120kW | 233kW | 630kW | 630kW |
| AC Rated Current | 173A | 336A | 910A | 910A |
| AC Rated Voltage | 400V | |||
| Allowable Grid Voltage Range | -15%~10% | |||
| Operating Frequency | 50/60Hz | |||
| Isolation Method | Power Frequency Isolation | |||
Send Inquiry to This Supplier
You May Also Like
-
Repower Times Distributed Liquid-cooled Energy Storage Cabinet 215~261kwhNegotiableMOQ: 0 Unit
-
Repower Times Portable Mobile Power Supply ne - 700NegotiableMOQ: 0 Unit
-
Repower Times Portable Mobile Power Supply Ne-1200/ne-1500NegotiableMOQ: 0 Unit
-
Repower Times 5.22kwh Integrated Home Energy Storage SystemNegotiableMOQ: 0 Unit
-
Repower Times Split Home Energy Storage System, 51.2v/314ahNegotiableMOQ: 0 Unit
-
Repower Times Foldable Solar Panels Nepv-100/nepv-200NegotiableMOQ: 0 Unit
-
Repower Times Stackable Home Energy Storage System, 5.22kwh - 26.1kwhNegotiableMOQ: 0 Unit
-
Repower Times Super Power Charging and Storage Cabin Ne-6000NegotiableMOQ: 0 Unit
-
Repower Times Hybrid Inverters (5.6kw - 10kw - 12kw)NegotiableMOQ: 0 Unit
-
Repower Times Mobile Energy Storage Maintenance Vehicle 100kwhNegotiableMOQ: 0 Unit