NYRY (VV32)

NYRY (VV32) photo-1

Product Spotlights

These power cables are used for electricity supply in low voltage installation systems. They are well adapted to underground use in industrial applications with an additional mechanical protection. They are suitable for laying Indoor, tunnel, cable trench, shaft or buried laying. The cable can withstand mechanical external forces and a certain tensile force, it widely used in transformer stations, electric power plants and industrial plants.
Negotiable MOQ: 3000 Meters (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Certification:
ISO9001
Application:
Overhead
Payment & Shipping
Payment Methods:
Port of Shipment:
Shanghai
Delivery Detail:
7 days
Certification ISO9001
Application Overhead

Application
These power cables are used for electricity supply in low voltage installation systems. They are well adapted to underground use in industrial applications with an additional mechanical protection. They are suitable for laying Indoor, tunnel, cable trench, shaft or buried laying. The cable can withstand mechanical external forces and a certain tensile force, it widely used in transformer stations, electric power plants and industrial plants.

Construction
● Conductor: Copper, class 1 or class 2, solid or stranded, circular or circular compacted conductors   
● Insulation: Polyvinyl chloride PVC
● Filler: Non-hygroscopic material
● Binder: Non-hygroscopic material
● Inner sheath: Polyvinyl chloride PVC
● Armour: Steel wire
● Binder :Non-hygroscopic material
● Outer sheath: Polyvinyl chloride PVC

Chaircteritics
Good electrical and mechanical properties. Resistance to abrasion, moisture and sunlight. Adequate resistance to oil and abrasion. 

Specification
IEC 60228 Conductors of Insulate Cables 
IEC 60502-1 Power Cables with Extruded Insulation and Their accessories for Rated Voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 1: Cables for Rated Voltages of 1 kV (Um=1.2kV) and 3kV(Um=3.6kV)

High reliability

Super high pressure

Less maintenance

Technical Parameter

IEC 60502-1

No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal
Steel Wire Diameter
Nominal
Sheath Thickness
Approx.
Overall Diameter
Approx. weight Max. D.C. Resistance of Conductor
at 20℃
No. × mm² No. mm mm mm mm kg/km Ω/km
2×1.5 1 0.8 0.8 1.8 13.7 322 12.1
2×2.5 1 0.8 0.8 1.8 14.5 367 7.41
2×4 1 1.0 0.8 1.8 16.3 459 4.61
2×6 1 1.0 1.25 1.8 18.2 652 3.08
2×10 6 1.0 1.25 1.8 20.7 842 1.83
2×16 6 1.0 1.25 1.8 22.3 1025 1.15
2×25 6 1.2 1.6 1.8 26.2 1501 0.727
2×35 6 1.2 1.6 1.8 28.2 1791 0.524
2×50 6 1.4 1.6 1.9 31.8 2231 0.387
2×70 12 1.4 2.0 2.0 36.5 3067 0.268
2×95 15 1.6 2.0 2.2 41.3 3907 0.193
2×120 18 1.6 2.0 2.3 44.3 4562 0.153
2×150 18 1.8 2.5 2.4 49.7 5874 0.124
2×185 30 2.0 2.5 2.6 54.1 6938 0.0991
2×240 34 2.2 2.5 2.7 59.7 8504 0.0754
2×300 34 2.4 2.5 2.9 65.7 10262 0.0601
2×400 53 2.6 2.5 3.2 72.7 12586 0.0470
3×1.5 1 0.8 0.8 1.8 14.2 357 12.1
3×2.5 1 0.8 0.8 1.8 15.1 411 7.41
3×4 1 1.0 0.8 1.8 16.9 528 4.61
3×6 1 1.0 1.25 1.8 18.9 750 3.08
3×10 6 1.0 1.25 1.8 21.7 991 1.83
3×16 6 1.0 1.25 1.8 23.4 1232 1.15
3×25 6 1.2 1.6 1.8 27.5 1801 0.727
3X35 6 1.2 1.6 1.8 29.7 2181 0.524
3×50 6 1.4 1.6 2.0 33.8 2777 0.387
No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal
Steel Wire Diameter
Nominal
Sheath Thickness
Approx.
Overall Diameter
Approx. weight Max. D.C. Resistance of Conductor
at 20℃
No. × mm² No. mm mm mm mm kg/km Ω/km
3×70 12 1.4 2.0 2.1 38.7 3843 0.268
3×95 15 1.6 2.0 2.2 43.7 4947 0.193
3×120 18 1.6 2.0 2.3 46.9 5829 0.153
3×150 18 1.8 2.5 2.5 52.8 7454 0.124
3×185 30 2.0 2.5 2.7 57.5 8924 0.0991
3×240 34 2.2 2.5 2.9 64.1 11150 0.0754
3×300 34 2.4 2.5 3.1 70.2 13441 0.0601
3×400 53 2.6 3.15 3.4 79.4 17564 0.0470
4×1.5 1 0.8 0.8 1.8 15.0 398 12.1
4×2.5 1 0.8 0.8 1.8 15.9 468 7.41
4×4 1 1.0 1.25 1.8 18.9 736 4.61
4×6 1 1.0 1.25 1.8 20.2 869 3.08
4×10 6 1.0 1.25 1.8 23.2 1157 1.83
4×16 6 1.0 1.6 1.8 25.9 1609 1.15
4×25 6 1.2 1.6 1.8 29.7 2162 0.727
4×35 6 1.2 1.6 1.9 32.3 2669 0.524
4×50 6 1.4 2.0 2.1 38.4 3739 0.387
4×70 12 1.4 2.0 2.2 42.2 4723 0.268
4×95 15 1.6 2.5 2.4 49.3 6591 0.193
4×120 18 1.6 2.5 2.5 52.9 7775 0.153
4×150 18 1.8 2.5 2.7 57.9 9280 0.124
4×185 30 2.0 2.5 2.9 63.5 11235 0.0991
4×240 34 2.2 2.5 3.1 70.5 13979 0.0754
4×300 34 2.4 3.15 3.3 78.9 17902 0.0601
4×400 53 2.6 3.15 3.6 87.2 22055 0.0470
5×1.5 1 0.8 0.8 1.8 15.8 449 12.1
5×2.5 1 0.8 0.8 1.8 16.9 530 7.41
5×4 1 1.0 1.25 1.8 20.1 836 4.61
5×6 1 1.0 1.25 1.8 21.5 992 3.08
5×10 6 1.0 1.6 1.8 25.6 1490 1.83
No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal
Steel Wire Diameter
Nominal
Sheath Thickness
Approx.
Overall Diameter
Approx. weight Max. D.C. Resistance of Conductor
at 20℃
No. × mm² No. mm mm mm mm kg/km Ω/km
5×16 6 1.0 1.6 1.8 27.8 1878 1.15
5×25 6 1.2 1.6 1.9 32.3 2563 0.727
5×35 6 1.2 2.0 2.0 36.7 3487 0.524
5×50 6 1.4 2.0 2.2 41.7 4436 0.387
5×70 12 1.4 2.0 2.3 45.9 5649 0.268
5×95 15 1.6 2.5 2.5 53.7 7849 0.193
5×120 18 1.6 2.5 2.7 57.8 9345 0.153
5×150 18 1.8 2.5 2.9 63.8 11208 0.124
5×185 30 2.0 2.5 3.0 69.4 13517 0.0991
5×240 34 2.2 3.15 3.3 79.0 17888 0.0754
5×300 34 2.4 3.15 3.6 86.6 21643 0.0601
5×400 53 2.6 3.15 3.9 95.8 26754 0.0470
3×2.5+1×1.5 1/1 0.8/0.8 0.8 1.8 15.7 450 7.41/12.1
3×4+1×2.5 1/1 1.0/0.8 1.25 1.8 18.4 699 4.61/7.41
3×6+1×4 1/1 1.0/1.0 1.25 1.8 19.9 833 3.08/4.61
3×10+1×6 6/1 1.0/1.0 1.25 1.8 22.5 1092 1.83/3.08
3×16+1×10 6/6 1.0/1.0 1.6 1.8 25.4 1527 1.15/1.83
3×25+1×16 6/6 1.2/1.0 1.6 1.8 28.8 2034 0.727/1.15
3×35+1×16 6/6 1.2/1.0 1.6 1.9 30.8 2403 0.524/1.15
3×50+1×25 6/6 1.4/1.2 2.0 2.0 36.5 3390 0.387/0.727
3×70+1×35 12/6 1.4/1.2 2.0 2.1 40.1 4261 0.268/0.524
3×95+1×50 15/6 1.6/1.4 2.0 2.3 45.5 5514 0.193/0.387
3×120+1×70 18/12 1.6/1.4 2.5 2.5 50.7 7148 0.153/0.268
3×150+1×70 18/12 1.8/1.4 2.5 2.6 54.4 8236 0.124/0.268
3×185+1×95 30/15 2.0/1.6 2.5 2.7 59.5 9994 0.0991/0.193
3×240+1×120 34/18 2.2/1.6 2.5 2.9 66.1 12399 0.0754/0.153
3×300+1×150 34/18 2.4/1.8 2.5 3.1 72.4 14964 0.0601/0.124
3×400+1×185 53/30 2.6/2.0 3.15 3.4 81.7 19493 0.0470/0.0991
3×2.5+2×1.5 1/1 0.8/0.8 0.8 1.8 16.4 496 7.41/12.1
3×4+2×2.5 1/1 1.0/0.8 1.25 1.8 19.2 762 4.61/7.41
No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal
Steel Wire Diameter
Nominal
Sheath Thickness
Approx.
Overall Diameter
Approx. weight Max. D.C. Resistance of Conductor
at 20℃
No. × mm² No. mm mm mm mm kg/km Ω/km
3×6+2×4 1/1 1.0/1.0 1.25 1.8 20.9 931 3.08/4.61
3×10+2×6 6/1 1.0/1.0 1.25 1.8 23.5 1201 1.83/3.08
3×16+2×10 6/6 1.0/1.0 1.6 1.8 26.9 1716 1.15/1.83
3×25+2×16 6/6 1.2/1.0 1.6 1.8 30.4 2280 0.727/1.15
3×35+2×16 6/6 1.2/1.0 1.6 1.9 32.2 2646 0.524/1.15
3×50+2×25 6/6 1.4/1.2 2.0 2.1 38.6 3783 0.387/0.727
3×70+2×35 12/6 1.4/1.2 2.0 2.2 42.3 4751 0.268/0.524
3×95+2×50 15/6 1.6/1.4 2.5 2.4 49.5 6613 0.193/0.387
3×120+2×70 18/12 1.6/1.4 2.5 2.5 53.6 8012 0.153/0.268
3×150+2×70 18/12 1.8/1.4 2.5 2.7 57.0 9114 0.124/0.268
3×185+2×95 30/15 2.0/1.6 2.5 2.9 63.4 11280 0.0991/0.193
3×240+2×120 34/18 2.2/1.6 2.5 3.0 69.5 13842 0.0754/0.153
3×300+2×150 34/18 2.4/1.8 2.5 3.3 76.4 16773 0.0601/0.124
3×400+2×185 53/30 2.6/2.0 3.15 3.6 86.0 21752 0.0470/0.0991
4×2.5+1×1.5 1/1 0.8/0.8 0.8 1.8 16.7 513 7.41/12.1
4×4+1×2.5 1/1 1.0/0.8 1.25 1.8 19.7 799 4.61/7.41
4×6+1×4 1/1 1.0/1.0 1.25 1.8 21.2 966 3.08/4.61
4×10+1×6 6/1 1.0/1.0 1.6 1.8 24.9 1403 1.83/3.08
4×16+1×10 6/6 1.0/1.0 1.6 1.8 27.3 1797 1.15/1.83
4×25+1×16 6/6 1.2/1.0 1.6 1.9 31.4 2420 0.727/1.15
4×35+1×16 6/6 1.2/1.0 1.6 1.9 33.6 2892 0.524/1.15
4×50+1×25 6/6 1.4/1.2 2.0 2.1 40.0 4086 0.387/0.727
4×70+1×35 12/6 1.4/1.2 2.0 2.3 44.2 5208 0.268/0.524
4×95+1×50 15/6 1.6/1.4 2.5 2.5 51.7 7261 0.193/0.387
4×120+1×70 18/12 1.6/1.4 2.5 2.6 55.7 8656 0.153/0.268
4×150+1×70 18/12 1.8/1.4 2.5 2.8 60.6 10202 0.124/0.268
4×185+1×95 30/15 2.0/1.6 2.5 2.9 66.3 12400 0.0991/0.193
4×240+1×120 34/18 2.2/1.6 2.5 3.2 73.5 15408 0.0754/0.153
4×300+1×150 34/18 2.4/1.8 3.15 3.4 82.2 19656 0.0601/0.124
4×400+1×185 53/30 2.6/2.0 3.15 3.7 90.8 24254 0.0470/0.0991




Product Tags: NYRY LV Power Cable , 0.6/1kV SWA PVC Cable , VV32 Copper Cable

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Manufacturer
Year Established
2009
Factory Size
50,000-100,000 square meters
Annual Export Value
Above US$100 Million