Home > Instruments & Meters > Electronic Instrument > Other Electronic Instruments > Genuine Keysight E4980B LCR Meter In Stock Built-In Data Storage Export Function For Test Report Archiving

Genuine Keysight E4980B LCR Meter In Stock Built-In Data Storage Export Function For Test Report Archiving

Genuine Keysight E4980B LCR Meter In Stock Built-In Data Storage Export Function For Test Report Archiving photo-1
Genuine Keysight E4980B LCR Meter In Stock Built-In Data Storage Export Function For Test Report Archiving photo-2
Genuine Keysight E4980B LCR Meter In Stock Built-In Data Storage Export Function For Test Report Archiving photo-3
Genuine Keysight E4980B LCR Meter In Stock Built-In Data Storage Export Function For Test Report Archiving photo-4

Product Spotlights

Brand new original Keysight E4980B LCR meter with full spot inventory and fast worldwide delivery, featuring a 20Hz–2MHz wide frequency band. Ultra-high measurement accuracy delivers stable L, C, R, Z and phase test data for resistors, capacitors, inductors and transformers. Equipped with high-speed sweep testing, touchscreen operation and USB remote control, perfectly matching lab R&D, component validation and production QC workflows. Full set of standard fixtures and official calibration certi
Negotiable MOQ: 1 Unit (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Warranty:
1 year
After-sales Service:
Online technical support
Brand:
Keysight
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
30 days
Warranty 1 year
After-sales Service Online technical support
Brand Keysight
Product Name Precision LCR Meter
Product Model E4980B
Frequency range 20 Hz to 2 MHz
Power supply method Power supply
Packaging method Cardboard packaging
Transport Package Outer packaging
Specification Standard specifications
Trademark Keysight
Origin United States

Genuine Keysight E4980B LCR Meter In Stock Built-In Data Storage Export Function For Test Report Archiving




E4980B           :  20 Hz to 2 MHz 

E4980BL-102:20 Hz to 1 MHz 

E4980BL-052:20 Hz to 500 kHz

E4980BL-032:20 Hz to 300 kHz

E4980A  -001:2 MHz With 40V Bias Source



Provides the best combination of accuracy, speed, and versatility for a wide range of component measurements



Highlights


Frequency

• 20 Hz to 2 MHz, with four-digit resolution in any range


Basic accuracy

• 0.05% basic accuracy with accurate measurement repeatability at low and high impedance


DC bias

• DC bias enhancement (Keysight Option 001)


More features

• 20 Vrms test signal (Keysight Option 001)

• High-speed measurements at 5.6 ms

• 201 points list measurement sweep

• Versatile PC connectivity (LAN, USB, and GPIB)


The Keysight E4980B precision LCR meter combines accuracy, speed, and versatility for a wide range of component measurements. The E4980B is an essential tool for general R&D and manufacturing test of components and materials, offering fast measurement speed and performance at both low and high impedance ranges.


The versatile LAN, USB, and GPIB PC connectivity enhances your design and test productivity. For materials measurements, the E4980B paired with the Keysight N1500A-005/006 materials measurement suite simplifies the measurement process from fixture setup to report generation.



Measurement parameters

• Cp-D, Cp-Q, Cp-G, Cp-Rp

• Cs-D, Cs-Q, Cs-Rs

• Lp-D, Lp-Q, Lp-G, Lp-Rp, Lp-Rdc

• Ls-D, Ls-Q, Ls-Rs, Ls-Rdc

• R-X

• Z-θd, Z-θr

• G-B

• Y- θd, Y-θr

• Vdc-Idc 1


Definitions

• Cp     Capacitance value measured with parallel-equivalent circuit model

• Cs      Capacitance value measured with series-equivalent circuit model

• Lp      Inductance value measured with parallel-equivalent circuit model

• Ls       Inductance value measured with series-equivalent circuit model

• D        Dissipation factor

• Q       Quality factor (inverse of D)

• G       Equivalent parallel conductance measured with parallel-equivalent circuit model

• Rp     Equivalent parallel resistance measured with parallel-equivalent circuit model

• Rs      Equivalent series resistance measured with series-equivalent circuit model

• Rdc   Direct-current resistance

• R       Resistance

• X       Reactance

• Z       Impedance

• Y       Admittance

• θd     Phase angle of impedance/admittance (degree)

• θr      Phase angle of impedance/admittance (radian)

• B       Susceptance

• Vdc   Direct-current voltage 

• Idc    Direct-current electricity



Deviation measurement function: Deviation from reference value and percentage of deviation fromreference value can be output as the result.

Equivalent circuits for measurement: Parallel, Series

Impedance range selection: Auto (auto range mode), manual (hold range mode)

Trigger mode: Internal trigger (INT), manual trigger (MAN), external trigger (EXT), GPIB trigger (BUS)



WhatsApp:+85268839563

WeChat    :13728300615





E4980B (1)E4980A (1)E4980B (2)E4980B (3)E4980B (4)


Product Tags: Keysight E4980B , E4980B meter , E4980B tester

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
1Yr
Verified Business License
Year Established
2021
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market
Location
Dongguan, Guangdong, China

Recommended Categories

Explore top categories and find suppliers for your specific needs