Power System Fuse RW11-12KV, 12KV Voltage Class With Drop-Out Design
Product Spotlights
As a professional manufacturer of electrical protection equipment, Jinhua Dika Electrical Equipment Co., Ltd. is proud to introduce our RW11-12KV Power System Fuse. Designed for reliability in demanding overhead distribution networks, this fuse integrates a proven drop-out mechanism with robust construction to provide critical circuit protection at the 12KV voltage level. Our commitment, backed by a structured quality management system, ensures that each unit delivers consistent performance for utilities and industrial power systems worldwide.
Core Product Features & Technical Advantages:
- Precision Drop-Out Action: The fuse is engineered so that the fuse tube automatically drops and visibly swings open upon operation. This provides a clear, unambiguous indication of a faulted circuit, enhancing safety for maintenance personnel and speeding up fault location and isolation.
- Robust Construction for Harsh Environments: Manufactured with high-grade materials, the fuse body and components resist corrosion, UV degradation, and mechanical stress. This ensures long-term reliability and minimal maintenance, even when installed in coastal, industrial, or other challenging outdoor conditions.
- Reliable Overcurrent Protection: At the heart of the device is a carefully calibrated fuse link. It provides precise time-current characteristics, ensuring that the fuse operates quickly under short-circuit conditions while withstanding temporary overloads, thus protecting expensive downstream equipment like transformers.
- Simplified Operation & Maintenance: The design allows for easy, hot-stick operation for opening and closing. The drop-out fuse tube can be readily replaced after an operation without the need for specialized tools, minimizing system downtime and reducing operational costs.
- Adaptable Mounting & Configuration: The RW11-12KV fuse is designed for standard pole mounting. Its configuration can be adapted with various mounting brackets and accessories to suit different pole types and system layouts, offering flexibility for system designers and installers.
Detailed Technical Specifications:
| Parameter | Specification / Description |
|---|---|
| Rated Voltage | 12 Kilovolts (KV) |
| Model Designation | RW11-12KV |
| Design Principle | Drop-Out (Expulsion Type) |
| Rated Current Range | Commonly available from 6.3A to 100A (Specific ratings customizable) |
| Breaking Capacity | Designed to interrupt fault currents as per system requirements |
| Insulation Level | Suitable for 12KV system BIL (Basic Insulation Level) |
| Mounting | Vertical or horizontal mounting on poles or structures |
| Ambient Temperature Range | Operational from -40°C to +40°C (or as per specific design) |
| Primary Application | Protection of transformers, feeders, and branch lines in overhead distribution networks |
Benefits for Your Power System:
- Enhanced System Safety: The visible break and isolation prevent accidental contact with live parts after a fault, protecting personnel.
- Improved Reliability: By quickly isolating faulted sections, it prevents cascading failures and minimizes the extent of outages, improving overall system reliability indices like SAIDI and SAIFI.
- Cost-Effective Protection: It serves as a primary protective device for distribution transformers, preventing costly damage and extending equipment life, offering a high return on investment.
- Operational Efficiency: The clear fault indication reduces the time needed for patrols to locate faults, allowing for faster restoration of service to unaffected customers.
Trust in a product backed by a manufacturer with a global footprint. Jinhua Dika Electrical Equipment Co., Ltd. supports an annual export value in the range of US$1-1.5 Million, serving diverse markets from North America and Europe to Southeast Asia and Africa. Our production processes are guided by a commitment to quality and consistency. We invite you to experience the difference that a well-engineered protection device can make. Contact us today to discuss your specific requirements for the RW11-12KV Drop-Out Fuse or to request detailed technical documentation and pricing.
Frequently Asked Questions (FAQ)
Q1: What is the primary function of the "drop-out" feature in this fuse?
A: The drop-out mechanism ensures that after the fuse operates (blows), the fuse tube disengages and hangs down, providing a visible air gap. This clearly indicates a faulted circuit and offers a physical isolation point, enhancing safety during maintenance.
Q2: Can this RW11-12KV fuse be used for both transformer and feeder protection?
A: Yes, it is commonly applied for both applications. For transformer protection, it is typically installed on the primary (high-voltage) side. For feeder protection, it is used to isolate faulted sections of an overhead line. The specific current rating is selected based on the protected load.
Q3: How do I select the correct current rating for my application?
A: The current rating should be chosen based on the maximum continuous load current of the circuit or transformer it protects, with a margin for temporary overloads. It is recommended to consult your system design specifications or contact our technical team for assistance in selection.
Q4: Is hot-stick operation required for this fuse?
A: Yes, for safety, all switching operations (opening or closing the fuse) on live lines must be performed using an insulated hot stick by trained personnel. The fuse is designed with fittings compatible with standard hot-stick tools.
Q5: What happens after the fuse operates? How is it restored to service?
A: After an operation, the dropped fuse tube must be replaced with a new one of the same rating. Once the fault is cleared and it is safe to proceed, a lineman uses a hot stick to open the upper contact, install the new tube, and then close the contact to restore service.
Q6: What are the typical mounting options for this fuse?
A: It is primarily designed for mounting on wooden, concrete, or steel utility poles using appropriate mounting brackets. The configuration (vertical/horizontal) depends on the specific system design and space constraints.
Q7: Are there different interrupting capacity options available?
A> The interrupting capacity is a key design parameter. We can provide fuses with different breaking capacities to match the fault current levels of your specific power system. Please provide your system's maximum fault current for accurate product specification.
Q8: What is the expected service life of this fuse under normal conditions?
A: The mechanical housing and contacts have a long service life, often exceeding 20-30 years when installed in standard environments. The fuse link itself is a consumable item and is replaced only after an operation. The overall longevity depends on environmental conditions and operational cycles.
Send Inquiry to This Supplier
You May Also Like
-
100A/200A 40.5kV Outdoor High Voltage Dropout Fuse Switch DisconnectorUS$ 18 - 30MOQ: 50 Units
-
11kV Outdoor High Voltage Distribution Dropout Fuse, Electrical ProtectionUS$ 18 - 30MOQ: 50 Units
-
High Voltage Outdoor Drop-out Cutout Fuse, Factory Direct SupplyUS$ 18 - 30MOQ: 50 Units
-
15kV 100A/200A Outdoor Porcelain Cut-out Fuse, Expulsion Type High Voltage Dropout FuseUS$ 18 - 30MOQ: 50 Units
-
Outdoor High Voltage Silicon Polymer AC Drop-out Fuse Cutout, Durable DesignUS$ 18 - 30MOQ: 50 Units
-
12kV Medium/High Voltage Ceramic Drop-out Fuse for Outdoor Electrical InstallationsUS$ 18 - 30MOQ: 50 Units
-
Outdoor Lightning Arrester HY5WS-17-50DL-TB for Solar Power Plant InstallationsUS$ 18MOQ: 5 Units
-
Lightning Arrester HY5WS-17-50DL-TB for 17kV Power Transmission LinesUS$ 18MOQ: 5 Units
-
Lightning Arrester HY5WS-17-50DL-TB for Wind Farm High-Voltage ProtectionUS$ 18MOQ: 5 Units
-
50kA Discharge Capacity Lightning Arrester HY5WS-17-50DL-TB for SubstationsUS$ 18MOQ: 5 Units