Dual-Wavelength 1940nm/1470nm Thulium Laser Platform for Versatile Skin Resurfacing
Product Spotlights
As a dedicated manufacturer of advanced aesthetic technology, Solana (Guangzhou) Beauty Technology Co., Ltd. proudly presents our flagship Dual-Wavelength Thulium Laser Platform. Engineered for professional clinics and medical spas, this system represents a significant leap in versatile skin resurfacing technology. Since our establishment in 2020, we have focused on integrating precision engineering with clinical efficacy, culminating in this platform designed to offer practitioners unparalleled flexibility and patient satisfaction. The core value lies in its dual-wavelength capability, allowing a single device to address a comprehensive range of dermatological concerns with optimized energy delivery for each indication.
Our platform harnesses the unique properties of Thulium-doped crystals to emit laser energy at two distinct and highly effective wavelengths: 1940nm and 1470nm. This dual-approach enables tailored treatments that were previously only possible with multiple devices.
Precision Ablation & Coagulation: The 1940nm wavelength is strongly absorbed by water in tissue, making it ideal for precise epidermal ablation and controlled coagulation. This allows for effective treatment of scars, wrinkles, and photodamage with minimal thermal damage to surrounding healthy tissue.
Deep Dermal Heating: The 1470nm wavelength has a lower water absorption coefficient, enabling deeper penetration into the dermis. This is perfect for non-ablative skin tightening, stimulating neocollagenesis, and treating vascular lesions with excellent efficacy.
Combined Synergy: Practitioners can utilize both wavelengths in a single treatment session for synergistic effects, such as combining superficial resurfacing with deep heating for comprehensive rejuvenation.
Adjustable Parameters: The system offers extensive customization with adjustable pulse duration, energy fluence, and repetition rate, ensuring protocols can be fine-tuned for different skin types and conditions.
Integrated Safety Architecture: Built with multiple redundant safety interlocks, real-time temperature monitoring, and a mandatory skin contact sensor, the platform prioritizes patient and operator safety above all.
User-Centric Design: Featuring a high-resolution touchscreen interface with pre-programmed treatment protocols and customizable patient profiles, the system reduces the learning curve and enhances clinic workflow efficiency.
The technical specifications of the Solana Dual-Wavelength Thulium Laser Platform are detailed below:
| Parameter | Specification |
| Active Medium | Thulium-doped Yttrium Aluminum Garnet (Tm:YAG) |
| Emission Wavelengths | 1940nm & 1470nm (independently selectable) |
| Maximum Output Power (per wavelength) | Up to 30W (configurable) |
| Pulse Duration Range | 0.5 ms - 500 ms (continuously adjustable) |
| Spot Size Options | 1mm, 2mm, 3mm, 5mm, 7mm, 10mm (interchangeable handpieces) |
| Cooling Method | Closed-loop water cooling with chiller |
| Control System | Industrial-grade PC with proprietary software, 15.6" touchscreen |
| Dimensions (Main Console) | Approx. 600mm (W) x 500mm (D) x 1100mm (H) |
| Power Requirements | AC 220V/50Hz or 110V/60Hz (configurable) |
The advantages of choosing this platform extend beyond its specifications. For clinic owners, it consolidates treatment capabilities, potentially replacing two or three single-wavelength devices, optimizing capital investment and treatment room space. For practitioners, the flexibility encourages creative and effective treatment plans, improving patient outcomes and satisfaction. Patients benefit from shorter overall treatment times, the potential for combined therapies, and predictable, reproducible results. The system's robust construction and reliable performance are backed by our ISO9001-certified manufacturing processes, ensuring every unit meets stringent quality standards.
Frequently Asked Questions (FAQ)
What is the primary difference between the 1940nm and 1470nm wavelengths in clinical practice?
The 1940nm wavelength is highly absorbed by water, making it excellent for superficial ablation and precise tissue removal (e.g., for acne scars). The 1470nm wavelength penetrates deeper with less surface absorption, making it ideal for non-ablative skin tightening and treating deeper vascular or pigmented lesions.Can this system be used for Fitzpatrick skin types V and VI?
Yes, with appropriate parameter settings. The adjustable pulse duration and energy allow practitioners to safely treat darker skin tones by minimizing the risk of post-inflammatory hyperpigmentation. Protocols for higher Fitzpatrick skin types are included in the training.What is the typical downtime associated with treatments using this platform?
Downtime varies by protocol. Non-ablative 1470nm treatments may have minimal to no downtime. Ablative 1940nm treatments can involve 3-7 days of recovery, depending on the aggressiveness of the settings. Fractional modes significantly reduce downtime.Does the system require special facility preparations, like three-phase power or external water supply?
No, it operates on standard single-phase power (configurable for 110V or 220V) and uses a closed-loop internal cooling system with a built-in chiller, eliminating the need for an external water connection.How does the dual-wavelength capability improve treatment outcomes for photoaging?
It allows a holistic approach. The 1940nm wavelength can address superficial wrinkles and texture, while the 1470nm wavelength simultaneously or sequentially treats deeper laxity and stimulates collagen, leading to more comprehensive rejuvenation than a single wavelength could achieve.What kind of training and support is provided with the purchase?
We provide comprehensive on-site installation, initial operator training, and clinical protocol guidance. Ongoing technical support is available, along with access to online resources and advanced technique workshops.Is the platform suitable for hair removal treatments?
While the primary design focus is skin resurfacing and rejuvenation, the 1470nm wavelength can be effective for permanent hair reduction on lighter hair types, adding to the system's versatility. Specific protocols are available.What is the expected lifespan of the laser module, and what are the maintenance requirements?
The solid-state Thulium laser module is designed for high durability. With proper care and regular preventive maintenance as outlined in the manual, the core laser source can provide reliable performance for many years. Maintenance primarily involves periodic cleaning and calibration checks.
Trust in the Solana Dual-Wavelength Thulium Laser Platform is built on a foundation of rigorous manufacturing standards and proven global acceptance. Our operations are certified under the ISO9001 Quality Management System, ensuring consistency and reliability in every unit produced. Our technology has found successful application across diverse markets, including North America, South America, Europe, and Asia, demonstrating its adaptability to different clinical environments and patient demographics. This global footprint, supported by an annual export value reflecting strong international demand, underscores the platform's performance and reliability. We invite you to experience how this versatile tool can transform your practice's service offerings, enhance patient results, and drive your business growth. Contact us today to arrange a detailed consultation or a demonstration.
Send Inquiry to This Supplier
You May Also Like
-
Picoway Laser for Tattoo Removal in Dermatology and Cosmetic ClinicsUS$ 2500 - 2800MOQ: 1 Unit
-
Tattoo Removal Picoway Machine Featuring Sub-Nanosecond Pulse DurationUS$ 2500 - 2800MOQ: 1 Unit
-
FDA-Cleared Picoway Laser System for Multi-Pass Tattoo Removal TreatmentsUS$ 2500 - 2800MOQ: 1 Unit
-
1064nm & 532nm Picoway Laser Equipment for Pigment and Vascular LesionsUS$ 2500 - 2800MOQ: 1 Unit
-
Pico Laser Tattoo Removal Device With Adjustable 755nm 1064nm 1320nm Wavelength SettingsUS$ 750 - 790MOQ: 1 Unit
-
Pico Laser Tattoo Removal Machine Ideal for Dermatology Clinics and Medical SpasUS$ 750 - 790MOQ: 1 Unit
-
Triple-Wavelength Pico Laser Machine: 755nm 1064nm 1320nm for Comprehensive Tattoo RemovalUS$ 750 - 790MOQ: 1 Unit
-
Durable Pico Laser Tattoo Removal Equipment With Extended Warranty and Technical SupportUS$ 750 - 790MOQ: 1 Unit
-
Advanced Pico Laser Technology for Tattoo Removal Featuring 755nm 1064nm 1320nmUS$ 750 - 790MOQ: 1 Unit
-
FDA-Cleared Pico Laser Tattoo Removal System for 755nm 1064nm 1320nm ApplicationsUS$ 750 - 790MOQ: 1 Unit