2711P-T12C6A1 Allen-Bradley Panelview Plus 1250 Touchscreen 12.1 In.
Product Spotlights
As a trusted supplier in the industrial automation sector, Rossonix Co., Limited leverages its decade of experience and global market presence to provide high-quality, reliable components like the Allen-Bradley PanelView Plus 1250. This 12.1-inch touchscreen Human-Machine Interface (HMI) represents a cornerstone for modern control systems, offering operators a clear, intuitive window into complex processes. We understand that in B2B transactions, reliability and performance are paramount. This unit delivers robust functionality, seamless integration with Rockwell Automation ecosystems, and a durable design built for demanding industrial environments, ensuring your operations run smoothly and efficiently.
Core Features & Technical Specifications:
The PanelView Plus 1250 is designed to be a powerful and versatile operator interface. Its key characteristics include:
- High-Resolution Touch Interface: The 12.1-inch color TFT LCD provides vibrant graphics and text, making it easy to monitor statuses, alarms, and data. The responsive touchscreen allows for quick navigation and input.
- Robust Processing Power: Equipped with an Intel Atom processor and 512 MB of RAM, it handles complex applications and multiple screens without lag, supporting real-time data display and logging.
- Versatile Connectivity: It features multiple communication ports for easy integration into your network. This includes Ethernet for fast network communication, USB ports for configuration and data transfer, and serial ports for legacy device connections.
- Durable Industrial Design: Built for panel mounting, it has a sturdy enclosure rated for industrial environments, capable of resisting vibrations, dust, and typical ambient conditions.
- Software Compatibility: Running on a Windows CE operating system, it is fully compatible with Rockwell Automation's FactoryTalk View Studio software for easy application development and deployment.
Detailed Technical Parameters:
| Parameter | Specification |
| Model Number | 2711P-T12C6A1 |
| Display Size | 12.1 inches (Diagonal) |
| Display Resolution | 800 x 600 pixels |
| Touchscreen Type | Analog Resistive Touch |
| Processor | Intel Atom |
| Memory (RAM) | 512 MB |
| Flash Memory | 1 GB |
| Communication Ports | 1 Ethernet (10/100 Mbps), 2 USB, 1 Serial (RS-232) |
| Operating System | Windows CE 6.0 |
| Power Supply | 24V DC |
| Mounting | Panel Mount (NEMA 4/4X or IP66 rated front) |
Advantages & Client Benefits:
- Enhanced Operational Efficiency: The intuitive interface reduces operator training time and allows for quicker response to system changes or alarms, minimizing downtime.
- Seamless System Integration: Its native compatibility with Allen-Bradley PLCs and networks simplifies installation and reduces engineering costs, creating a cohesive automation solution.
- Reliability in Tough Conditions: The industrial-grade construction ensures long-term performance in factories, plants, and outdoor installations, providing a dependable interface year after year.
- Flexible Application Development: Using FactoryTalk View Studio, engineers can create custom screens tailored to specific processes, from simple monitoring to complex control sequences.
- Clear Data Visualization: The sizable, high-resolution screen can display detailed process diagrams, trend charts, and live data, improving decision-making and process oversight.
Rossonix Co., Limited stands behind this product with a solid track record. Established in 2011 and holding ISO9001/9000 certifications for quality management, we have built a reputation for reliability. With an annual export value ranging between US$5-10 Million and a team of 11-50 dedicated professionals, we serve a vast global network spanning North America, Europe, Asia, and beyond. Our logistical capabilities, shipping from major ports like Shenzhen and Hong Kong, ensure timely delivery. When you choose this PanelView Plus 1250 through us, you are not just buying a component; you are gaining a reliable partner committed to supporting your industrial automation needs with quality products and dependable service. We encourage you to contact us for detailed quotations, technical support, or to discuss your specific application requirements.
Frequently Asked Questions (FAQ):
-
What is the main difference between the PanelView Plus 1250 and other PanelView models?
The PanelView Plus 1250 is part of the "Plus" series which offers enhanced processing power, more memory, and runs on Windows CE, allowing for more complex applications compared to some older standard PanelView units. -
Can this HMI communicate with non-Rockwell Automation PLCs?
While optimized for Allen-Bradley/Rockwell networks, it can communicate with other devices using standard protocols like Modbus via its serial or Ethernet ports, though configuration may require additional steps. -
What software is needed to program applications for this unit?
Rockwell Automation's FactoryTalk View Studio Machine Edition or similar versions are typically used to develop and deploy the HMI applications. -
Is the touchscreen resistant to chemicals or oils?
The front face is rated NEMA 4/4X (or IP66), which provides protection against water, dust, and oil ingress. However, direct exposure to harsh chemicals should be avoided; optional protective overlays are available. -
What is the typical power consumption of this device?
It operates on 24V DC. The specific power draw is moderate, designed for standard industrial power supplies. Exact wattage can be found in the technical datasheet. -
Does it support remote access or monitoring?
Yes, through its Ethernet port, the HMI can be integrated into a network, allowing for remote viewing of screens and data (with proper network security setup). -
Are spare parts or repair services available for this model?
As a trading company with access to global supply channels, Rossonix can often assist with sourcing replacement parts or compatible accessories. Repair services may be available through specialized third-party providers. -
What is the expected lifespan or operational temperature range?
These industrial HMIs are designed for long-term use. The operational temperature range is typically from 0°C to 50°C (32°F to 122°F), ensuring functionality in most industrial settings.
Send Inquiry to This Supplier
You May Also Like
-
2711P-T10C6B2 Allen-Bradley Powerview Plus 1000 10.4 In.NegotiableMOQ: 1 Piece
-
2711P-T10C6B1 Allen-Bradley Powerview Plus 1000 10.4 In.NegotiableMOQ: 1 Piece
-
2711P-T10C6A1 Allen-Bradley Powerview Plus 1000 Touchscreen 10.4 In.NegotiableMOQ: 1 Piece
-
2711P-T10C6D1 Allen-Bradley Powerview Plus 1000 10.4 In.NegotiableMOQ: 1 Piece
-
2711P-T10C6D2 Allen-Bradley Panelview Plus 1000NegotiableMOQ: 1 Piece
-
2711P-T10C4B1 Allen-Bradley Powerview Plus 1000 10.4 inNegotiableMOQ: 1 Piece
-
2711P-T12C15A2 Allen-Bradley Panelview Plus 1250 12.1 InchesNegotiableMOQ: 1 Piece
-
2711P-T10C15A2 Allen-Bradley Panelview Plus 1000 10.4 In.NegotiableMOQ: 1 Piece
-
2711P-T10C15A1 Allen-Bradley Panelview Plus 1000 10.4 In.NegotiableMOQ: 1 Piece
-
2711P-T12C15A1 Allen-Bradley Panelview Plus 1250 12.1 InchesNegotiableMOQ: 1 Piece