Product Spotlights

Dual isolated 4-20mA & 0-10V outputs for maximum system compatibility. Hall effect non-contact sensing ensures safety & measures DC/AC/pulsed currents. High accuracy (±1%), fast response (<20μs), and robust design for industrial use. Simplifies integration, reduces costs, and enhances reliability in motor drives, renewable energy, and automation.
US$ 30 ≥10 Units
Key Specifications
Get Latest Price
Measurement Principle:
Hall Effect, Open Loop
Output Signals:
4-20mA and 0-10V, Isolated
Primary Current Range:
Customizable (e.g., 0-50A, 0-100A)
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Measurement Principle Hall Effect, Open Loop
Output Signals 4-20mA and 0-10V, Isolated
Primary Current Range Customizable (e.g., 0-50A, 0-100A)
Power Supply 12-24V DC, 15-30V DC
Accuracy ±1% typical (at 25°C)
Response Time < 20 microseconds
Isolation Voltage Available upon request
Operating Temperature -25°C to +70°C
Mounting Type PCB Mount or DIN Rail Mount
Housing Material Plastic (UL94-V0) or Metal (Optional)

As a dedicated manufacturer with over a decade of experience in electrical measurement solutions, Jinhua Dika Electrical Equipment Co., Ltd. proudly presents our advanced Dual Output Hall Effect DC Current Transducer Module. Engineered for precision and reliability in demanding industrial environments, this module seamlessly converts DC current into two industry-standard, electrically isolated analog signals: 4-20mA and 0-10V. It is the ideal, versatile solution for system integrators and OEMs who require robust, accurate, and flexible current monitoring for applications ranging from motor control and renewable energy systems to power supply monitoring and battery management.

Our commitment to quality is underscored by our adherence to stringent management standards, ensuring every transducer delivers consistent performance. The dual-output design provides unparalleled integration flexibility, allowing you to connect to a wider array of PLCs, data loggers, and control systems without the need for additional signal converters. This not only simplifies your system design but also enhances overall cost-effectiveness and reliability.

Key Product Features and Technical Advantages:

  • Dual Isolated Outputs: Simultaneous 4-20mA current loop and 0-10V voltage output provide maximum compatibility with different control and monitoring systems. The isolation between input, output, and power supply protects sensitive equipment from high-voltage transients and ground loops.
  • Hall Effect Sensing Technology: Utilizes non-contact, open-loop Hall effect principle for measuring DC, AC, and pulsed currents. This ensures galvanic isolation from the primary circuit, enhanced safety, low power loss, and excellent linearity.
  • High Accuracy and Stability: Features a typical accuracy of ±1% at room temperature, with low temperature drift and excellent long-term stability, ensuring trustworthy measurements over the product's lifespan.
  • Wide Measurement Range: Available in various primary nominal current (IPN) ranges (e.g., 5A, 50A, 100A, 300A) to suit diverse application needs. Custom ranges are available upon request.
  • Compact and Robust Design: The module is designed for easy PCB mounting or DIN rail mounting with an optional adapter. The housing is typically made from flame-retardant plastic (UL94-V0), with metal enclosures optional for enhanced EMI shielding.
  • Fast Response and Wide Bandwidth: With a response time of less than 20 microseconds, it can accurately track rapid current changes, making it suitable for inverter and PWM motor drive applications.

This transducer offers significant benefits for your operations:

  • Simplified System Integration: Eliminates the need for separate transducers or signal conditioners for different input types, reducing component count, wiring complexity, and cabinet space.
  • Enhanced System Reliability: The built-in isolation and robust construction minimize the risk of signal interference and device failure, leading to higher system uptime.
  • Cost-Effective Monitoring: Provides a single-device solution for dual-channel monitoring needs, offering better value compared to purchasing two separate single-output sensors.
  • Versatile Application Scope: Perfect for solar inverters, UPS systems, welding equipment, industrial automation, elevator control, and EV charging stations.

Detailed Technical Specifications:

Parameter Specification
Input Current (IPN) Customizable (e.g., ±5A, ±50A, ±100A, ±300A)
Output 1 4-20mA DC (Two-wire or Three-wire)
Output 2 0-10V DC
Supply Voltage +12V to +24V DC, ±10% (or +15V to +30V DC for some models)
Overall Accuracy (25°C) ±1% of IPN (Typical)
Linearity
Response Time
Operating Temperature -25°C to +70°C
Storage Temperature -40°C to +85°C
Isolation Voltage 2.5kV AC/50Hz/1min (Standard, higher available)

Trust in a partner with a proven global footprint. Jinhua Dika Electrical Equipment Co., Ltd. supports an annual export value of US$1-1.5 Million, serving key markets across North America, South America, Europe, Asia, Africa, and Oceania from major Chinese ports like Shanghai and Ningbo. Our operational framework is guided by a commitment to quality and social responsibility. This dual-output current transducer embodies our dedication to providing innovative, reliable, and cost-effective measurement solutions that help you build more efficient and intelligent systems. Contact us today to discuss your specific requirements or to request samples, and experience the Dika difference in precision current sensing.

Frequently Asked Questions (FAQ)

  1. Q: Can this transducer measure AC current as well?
    A: Yes. While the title specifies DC, the Hall effect open-loop design inherently allows it to measure AC and pulsed currents. The output will be a DC signal proportional to the RMS value of the AC input.
  2. Q: Are the two outputs (4-20mA and 0-10V) completely independent and isolated?
    A: Yes. Both outputs are generated from the same measured current but are electrically isolated from each other and from the primary current circuit. This allows you to connect them to two different systems without causing ground loop issues.
  3. Q: What is the maximum current it can measure?
    A: The standard catalog includes models up to 300A. For higher currents, we can provide custom solutions or recommend using an external current shunt in conjunction with the transducer.
  4. Q: How do I select the correct power supply voltage?
    A: Most standard models operate on +12V to +24V DC. The specific required voltage range will be clearly stated in the datasheet for your chosen model. Ensure your power supply is stable and within the specified range.
  5. Q: Is zero and span adjustment available on this module?
    A: Typically, our standard modules are factory-calibrated. However, versions with onboard potentiometers for zero and span adjustment are available as an option for field fine-tuning.
  6. Q: What is the typical installation method?
    A: The module is designed for direct PCB mounting via pins. For panel or DIN rail mounting, a separate DIN rail mounting bracket or an enclosure with a DIN rail clip can be provided as an accessory.
  7. Q: Can you provide custom output ranges instead of 4-20mA/0-10V?
    A: Yes. We offer customization services. Outputs like 0-5V, 0-20mA, or other specific voltage/current ranges can be developed based on your project's requirements and order quantity.
  8. Q: What is the lead time for samples and bulk orders?
    A: Sample lead time is typically 7-10 working days. For bulk production orders, the lead time depends on the order quantity and customization level, generally ranging from 3 to 5 weeks. We ship globally from multiple ports for efficient delivery.
Product Tags: Hall Effect Current Transducer , 4-20mA 0-10V Current Sensor , Dual Output Current Transducer

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
1Yr
Verified Business License
Business Type
Manufacturer
Annual Export Value
US$1 Million - US$1.5 Million
Total Employees
11 - 50 People
Product Certifications
HACCP, TL900, QS9000, SA8000, ISO9001, ISO9004, ISO17799, ISO9000, ISO14000, ISO10441, ISO16949, TS16969, ISO19011:2000, OHSAS18001, Others