Dual-Function Q-Switch ND:YAG Laser: Tattoo Removal and Carbon Peel Skin Rejuvenation System
Product Spotlights
As a dedicated manufacturer of aesthetic medical equipment, Solana (Guangzhou) Trading Co., Ltd. is proud to introduce our advanced Dual-Function Q-Switch ND:YAG Laser System. Engineered for professional clinics and medspas, this system combines high-performance tattoo removal with effective carbon peel skin rejuvenation in one reliable platform. We leverage our manufacturing expertise, backed by ISO9001 quality management systems, to deliver a device that offers practitioners versatility, consistent results, and operational efficiency, helping you expand your service offerings and meet diverse client needs.
This system is designed to address two of the most sought-after treatments in aesthetic medicine. The core of its technology is the Q-Switched ND:YAG laser, which delivers ultra-short, high-peak-power pulses of light. This specific pulse characteristic is crucial for its dual functionality:
For Tattoo Removal: The nanosecond pulses are absorbed by tattoo ink particles, creating a photoacoustic effect that shatters the ink into tiny fragments. These fragments are then naturally eliminated by the body's lymphatic system over time. The system typically operates at its fundamental 1064nm wavelength for deeper, darker inks and can utilize a frequency-doubled 532nm wavelength for red, orange, and other superficial colors.
For Carbon Peel Rejuvenation: In this non-ablative treatment, a thin layer of medical-grade carbon lotion is applied to the skin. The laser energy, attracted to the dark carbon particles, rapidly heats them. This process creates a mild exfoliation and, more importantly, generates a controlled thermal effect in the underlying dermis. This stimulates collagen production, tightens pores, and improves skin texture and tone, resulting in a brighter, smoother complexion.
The system's design prioritizes both practitioner control and patient comfort. Key operational features include:
Adjustable Parameters: Precise control over fluence (energy density), pulse repetition rate, and spot size allows for customized treatments tailored to different skin types, conditions, and treatment areas.
Intelligent User Interface: A color touchscreen provides easy access to pre-set treatment protocols for common indications, while also allowing for manual adjustments. Treatment history and settings can often be saved for returning clients.
Integrated Safety: Built-in skin type sensors and contact cooling tips (or integrated air cooling) help protect the epidermis, minimize discomfort, and reduce the risk of side effects like hyperpigmentation or blistering.
Robust Construction: Built for the demands of a clinical environment, the system features a stable mobile cart, durable components, and reliable laser source technology for long-term, consistent performance.
The primary benefits for your practice are clear. By investing in a dual-function system, you consolidate equipment needs, saving on cost, space, and maintenance compared to purchasing two separate machines. It enhances treatment flexibility, allowing you to seamlessly switch between removal and rejuvenation services during a single client visit. This efficiency can lead to increased patient throughput and higher revenue per device. For the patient, treatments are generally faster with the combined system, and the non-invasive nature of the carbon peel offers minimal downtime, making it an attractive option for busy individuals.
To provide a clearer overview, here are some typical technical specifications of the system:
| Specification | Detail |
| Laser Medium | ND:YAG Rod |
| Primary Wavelength | 1064 nm |
| Optional Wavelength | 532 nm (Frequency Doubled) |
| Pulse Width | 5-10 ns |
| Max Pulse Energy | Up to 2000 mJ @ 1064nm |
| Repetition Rate | 1-10 Hz |
| Spot Sizes | 2, 3, 4, 6, 8 mm (or adjustable) |
| Cooling Method | Air Cooling / Contact Cooling Tip |
| Power Supply | AC 110V/220V, 50/60Hz |
Trust in a product from a source committed to quality and global reach. Solana (Guangzhou) Trading Co., Ltd. operates under an ISO9001 certified quality management system, ensuring consistent manufacturing standards. Our products are trusted by professionals across diverse markets including North America, Europe, and Asia, with an annual export value reflecting significant international confidence. This dual-function laser system embodies our focus on providing effective, multi-purpose solutions for the growing aesthetic industry. It is designed to be a workhorse for your practice, delivering professional-grade results that can help build your reputation and client base. We invite you to contact us for more detailed specifications, pricing, and to discuss how this versatile system can be integrated into your service portfolio.
Frequently Asked Questions (FAQ)
Q: How many treatment sessions are typically needed for tattoo removal with this laser?
A: The number of sessions varies significantly based on factors like ink color, depth, age of the tattoo, and individual skin response. Professional black or dark blue tattoos may require 6-12 sessions spaced 6-8 weeks apart, while amateur tattoos might need fewer. A consultation and patch test are recommended to establish a realistic treatment plan.
Q: Is the carbon peel treatment painful, and what is the downtime?
A: The carbon peel is generally well-tolerated. Patients often describe a warm, snapping sensation, similar to a rubber band against the skin. Topical anesthetic can be used if needed. There is typically no downtime; patients may experience mild redness that subsides within a few hours, and they can resume normal activities immediately after the procedure.
Q: Can this laser treat all skin types (Fitzpatrick I-VI)?
A: The Q-Switched ND:YAG laser at 1064nm is considered one of the safer options for darker skin types (Fitzpatrick IV-VI) for tattoo removal, as it is less absorbed by melanin. However, extreme caution and lower fluence settings must be used. For the carbon peel and treatments with the 532nm wavelength, it is more suitable for lighter skin types (I-III). A thorough skin assessment by a trained practitioner is mandatory.
Q: What is the maintenance schedule and expected lifespan of the laser system?
A: Regular maintenance includes cleaning optical components, checking cooling systems, and calibrating the energy output. The flashlamp in the laser cavity is a consumable item typically needing replacement every 1-5 million shots, depending on usage. With proper care and maintenance, the core laser system can have an operational lifespan of 8-10 years or more.
Q: Does the system come with training and technical support?
A> Yes, comprehensive initial training on operation, safety protocols, and treatment techniques is typically provided. We also offer detailed user manuals and access to technical support for troubleshooting. Ongoing clinical training resources may be available upon request.
Q: What safety features are incorporated to protect both the patient and operator?
A> Key safety features include a key switch for operator-only access, a ready-to-fire indicator with audible beep, skin contact sensors that only allow firing when the handpiece is properly placed, integrated cooling to protect the epidermis, and protective eyewear for both patient and operator that is specific to the 1064nm/532nm wavelengths.
Q: Are treatment protocols pre-programmed into the system?
A> Yes, the system usually includes a library of pre-set treatment protocols for common indications (e.g., amateur black tattoo, professional colored tattoo, carbon peel for oily skin). These serve as a starting point, which the practitioner can then customize based on the individual client's assessment.
Q: What is the difference between this Q-Switched laser and a Picosecond laser for tattoo removal?
A> The primary difference is pulse duration. Q-Switched lasers deliver pulses in the nanosecond range, while Picosecond lasers are faster (picosecond range). Picosecond lasers can be more effective on certain stubborn inks, especially blues and greens, and may require fewer sessions. However, Q-Switched ND:YAG lasers like this one remain a highly effective, proven, and often more cost-effective technology for a wide range of tattoo colors and skin rejuvenation procedures.
Send Inquiry to This Supplier
You May Also Like
-
CE Certified Professional Portable CO2 Fractional Laser for Skin Resurfacing With 10600nm WavelengthUS$ 1000 - 1300MOQ: 1 Unit
-
Portable Fractional CO2 Laser Device With Integrated Cooling for Safe Skin Resurfacing Scar Remoal Vaginal RejuvenationUS$ 1000 - 1300MOQ: 1 Unit
-
Professional Skin Cooling Machine for Laser Spa Devices, 1500W Cooling PowerUS$ 800 - 890MOQ: 1 Unit
-
Portable Skin Cooling Machine for Home Use, Compact Design With Adjustable TemperatureUS$ 800 - 890MOQ: 1 Unit
-
Clinic-Grade Skin Cooling Machine for Laser Treatments, Efficient Cooling With Low NoiseUS$ 800 - 890MOQ: 1 Unit
-
Skin Cooling Machine Featuring Automatic Temperature Control for Enhanced Spa SafetyUS$ 800 - 890MOQ: 1 Unit
-
Skin Cooling Machine With CE ROHS Certified 220V Cooling System for Laser SpasUS$ 800 - 890MOQ: 1 Unit
-
Latest 22D Ultramax Hifu Machine With Three Handles for Vaginal Rejuvenation Facelift Fat RemovalUS$ 1200 - 1250MOQ: 1 Unit
-
Latest Ai 3D Facial Scanner Skin Analysis Hair & Scalp Analyzer Salon Equipment Factory PriceUS$ 850 - 950MOQ: 1 Unit
-
New 2 in 1 ND YAG Laser Three Wavelengths 808nm 755nm 1064nm Diode Laser Permanent Painfree Hair Removal Tattoo Removal MachineUS$ 900 - 950MOQ: 1 Unit




