Home > Furniture > Hotel Furniture > Other Hotel Furniture > HN-CR9 Chemical Cleaning Locker for Laboratory, Corrosion-Resistant Finish With Hanging Rod & Adjustable Shelving, Easy Assembly

HN-CR9 Chemical Cleaning Locker for Laboratory, Corrosion-Resistant Finish With Hanging Rod & Adjustable Shelving, Easy Assembly

HN-CR9 Chemical Cleaning Locker for Laboratory, Corrosion-Resistant Finish With Hanging Rod & Adjustable Shelving, Easy Assembly photo-1
HN-CR9 Chemical Cleaning Locker for Laboratory, Corrosion-Resistant Finish With Hanging Rod & Adjustable Shelving, Easy Assembly photo-2
HN-CR9 Chemical Cleaning Locker for Laboratory, Corrosion-Resistant Finish With Hanging Rod & Adjustable Shelving, Easy Assembly photo-3
HN-CR9 Chemical Cleaning Locker for Laboratory, Corrosion-Resistant Finish With Hanging Rod & Adjustable Shelving, Easy Assembly photo-4
HN-CR9 Chemical Cleaning Locker for Laboratory, Corrosion-Resistant Finish With Hanging Rod & Adjustable Shelving, Easy Assembly photo-5
US$ 80 - 200 MOQ: 5 Combos
Key Specifications
Get Latest Price
Material:
Other, Stainless steel
Size:
Single
Style:
Modern
Payment & Shipping
Payment Methods:
Port of Shipment:
zhengzhou,qingdao
Delivery Detail:
10 days
Material Other, Stainless steel
Size Single
Style Modern
Kind Cabinet
Folded Unfolded
Condition New
Fixed Fixed
Customized Customized
Transport Package various
Specification standard
Trademark juntuo
Origin luoyang

This manual provides a comprehensive overview of the HN-CR9 Chemical Cleaning Locker, a specialized storage solution engineered to address the unique safety, organization, and material compatibility challenges present in laboratory, industrial, and healthcare environments where corrosive substances are handled.

Target Audience: Laboratory managers, facility safety officers, procurement specialists, and operations personnel in biotech, pharmaceutical, educational, and industrial research settings.

1. Problem Statement: The Challenge of Corrosive Material Storage

Storing cleaning chemicals, acid-based solutions, solvents, and associated tools in standard metal cabinets presents significant risks:

  • Material Degradation: Fumes and spills corrode standard steel, compromising structural integrity.

  • Safety Hazards: Leaking containers can damage cabinets and create dangerous reactions or exposure.

  • Organization Failure: Improper storage of reactive chemicals together or with tools increases risk.

  • Regulatory Non-Compliance: May fail to meet OSHA, ISO, or other lab safety standards for chemical storage.

cfsafcas45723saias045sadpofew1111

2. Solution Overview: The HN-CR9 Engineered Response

The HN-CR9 is purpose-built from the ground up to function as a primary control measure in your lab's safety protocol. Its core design integrates corrosion-resistant materials, adaptable organization, and secure containment to mitigate the risks associated with storing hazardous cleaning and maintenance chemicals.

3. Core System Components & Functional Breakdown

3.1. Corrosion-Resistant Enclosure System

  • Material: Constructed from cold-rolled steel treated with a specialized, chemically-resistant epoxy or powder coating. This finish is selected for its impermeability to fumes and resistance to a wide range of acids, alkalis, and solvents commonly found in laboratory cleaning agents.

  • Seam & Joint Design: Welded and sealed seams minimize areas where corrosive vapors can penetrate and attack the substrate metal from within.

3.2. Adaptive Interior Organization System

  • Stainless Steel Hanging Rod: A solid stainless steel rod provides a non-reactive, easy-to-clean mounting point for tools, mop heads, and brushes, keeping them off the floor and allowing for air circulation.

  • Adjustable Shelving: Shelves are coated with the same corrosion-resistant material and feature adjustable brackets. This allows customization for different container sizes (e.g., 1-gallon jugs, spray bottles, smaller acid containers) and ensures proper segregation of incompatible substances.

  • Integrated Drip Management (Optional): For labs handling wet equipment, a removable polymer catch basin can be specified to contain incidental drips or spills from tools, preventing liquid contact with the cabinet floor.

3.3. Safety & Access System

  • Ventilation Ports (Passive): Incorporates baffled ventilation openings to allow for passive diffusion of potentially accumulated vapors, reducing internal pressure and fume concentration. (Note: Not a substitute for fume hoods or active ventilation for volatile substances.)

  • Robust Locking Mechanism: Features a chemical-resistant lock cylinder and handle to ensure secure, restricted access to hazardous materials, a key requirement for safety audits.

fdcsds0909dsfvsdvgs034

4. Technical Specifications & Configuration Options

Category Standard Specification Available Customization (OEM/ODM)
Model HN-CR9 Chemical Cleaning Locker Client-specific model numbers available
Primary Application Laboratory, Industrial Cleanroom, Healthcare Prep Areas Can be specified for other corrosive environments
Frame & Body Material Cold-Rolled Steel with Chemical-Resistant Coating Alternative: 304 or 316 Grade Stainless Steel
Interior Fittings Material Epoxy-Coated Steel or Stainless Steel Full stainless steel interior upgrade
Key Features Adjustable Shelving, Stainless Hanging Rod, Lock Add: Spill Containment Sump, Pegboard, Label Holders
Ventilation Passive Baffled Vents Optional: Port for ducting to extraction system
Dimensions (HxWxD) Typical: 1800mm x 900mm x 450mm Fully customizable to fit allocated lab space
Assembly Knock-Down (KD) or Welded KD for easier lab entry; Welded for permanence
Compliance Designed to support lab safety protocols Can be tailored to specific regulatory frameworks

5. Recommended Application Workflows

  • Centralized Chemical Storage: Designate the HN-CR9 as the sole storage point for all laboratory-grade cleaning and disinfectant solutions, separating them from analytical reagents.

  • Spill Response Station: Configure with absorbents, neutralizers, PPE, and cleanup tools, making it a dedicated hub for emergency response.

  • Equipment & Tool Storage: Use the hanging rod and shelves to store dedicated lab cleaning apparatus (e.g., acid-resistant mops, brushes, wet-vacuums) to prevent cross-contamination with everyday tools.

  • Wet/Dry Separation: Utilize adjustable shelves to create distinct zones for liquid containers (lower) and dry supplies/PPE (upper), with the catch basin managing tool drainage.

6. Installation, Maintenance & Safety Protocols

  • Installation: Position on a level, impervious floor away from direct heat sources and incompatible materials. Ensure adequate clearance for door swing and ventilation.

  • Maintenance: Inspect regularly for coating damage. Clean spills immediately with appropriate neutralizers. Wipe exterior with a damp cloth; avoid abrasive cleaners.

  • Labeling: Clearly label the cabinet exterior with its contents (e.g., "CORROSIVE CLEANING AGENTS ONLY") and appropriate hazard pictograms as per your institution's Globally Harmonized System (GHS) protocol.

Frequently Asked Questions (FAQ)

Q1: What specific chemicals is the corrosion-resistant coating rated for? Can it handle concentrated acids?
A1: The standard coating is highly resistant to a broad spectrum of common laboratory cleaning agents, diluted acids, alkalis, and solvents. However, for storage of high-concentration mineral acids (e.g., 98% Sulfuric Acid) or strong oxidizing agents, we strongly recommend specifying the optional 304 or 316 Stainless Steel upgrade for maximum safety and longevity. A technical datasheet with chemical resistance charts is available upon request.

Q2: Does the passive ventilation replace the need for a fume hood for these chemicals?
A2: Absolutely not. The passive vents are designed only to prevent the buildup of minor vapors from closed containers and allow general air exchange. They do not provide active containment or exhaust. All volatile, fume-producing chemicals must be stored and handled in accordance with your lab's safety policy, typically within a properly functioning fume hood or dedicated volatile storage cabinet.

Q3: We need to store both liquid chemicals and long-handled tools like mops and squeegees. Can the interior be configured for both?
A3: Yes, this is a key strength of the HN-CR9's design. Using the adjustable shelving system, you can create a lower section with shelves for chemical containers. The upper section can be left open to accommodate the stainless steel hanging rod, from which S-hooks (included) can be used to suspend long-handled tools vertically, maximizing space efficiency and keeping wet tools contained and organized.


The contact information of the sales manager is shown in the picture below. You can make inquiries directly without waiting.


MP2

Product Tags: Chemical Cleaning Locker , Corrosion Resistant Locker , Laboratory Storage Cabinet

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
1Yr
Verified Business License
Business Type
Manufacturer
Year Established
2017
Port of Shipment
Qingdao
Main Markets
North America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs