Home > Industrial Equipment & Components > Valve > Pressure Reducing Valve > Pressure Reducing Pilot DN100 Hydraulic Control Valve

Pressure Reducing Pilot DN100 Hydraulic Control Valve

Pressure Reducing Pilot DN100 Hydraulic Control Valve photo-1
Negotiable MOQ: 1 Set (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Material:
Other, Stainless Steel Diaphragm, Brass Body
Size Range:
DN15 to DN100 (1/2“ to 4“)
Operating Temperature:
-20°C to +150°C
Payment & Shipping
Payment Methods:
Port of Shipment:
Shanghai, China
Delivery Detail:
7 days
Material Other, Stainless Steel Diaphragm, Brass Body
Size Range DN15 to DN100 (1/2“ to 4“)
Operating Temperature -20°C to +150°C
Pressure Range Inlet 0.2-1.0 MPa, Outlet Adjustable
Connection Type Flanged or Threaded Options
Application Steam, Water, Compressed Air Systems
Model Series Pilot-Operated PRV Series
Function Constant Outlet Pressure Maintenance
Installation Horizontal or Vertical Pipeline

Shanghai Sote Valve Co., Ltd., a trusted industrial valve manufacturer based in Shanghai, China, presents its precision-engineered Balanced Diaphragm Pressure Reducing Pilot Valve. Designed for critical pressure management applications, this valve ensures exceptional stability in demanding industrial environments where constant outlet pressure is non-negotiable. Our valve's robust construction and intelligent pilot operation make it ideal for steam distribution networks, compressed air systems, and water treatment plants requiring reliable pressure control across wide temperature variations.

Key technical advantages include:

  • Self-compensating diaphragm design eliminates pressure fluctuations caused by upstream changes

  • High-accuracy pilot system maintains outlet pressure within ±5% deviation

  • Wide temperature compatibility from -20°C to +150°C for versatile applications

  • Corrosion-resistant components with stainless steel diaphragm and brass body construction

  • Low maintenance requirements due to balanced seat design reducing wear

Technical specifications for standard models:

Parameter Specification
Pressure Adjustment Range 0.05 - 0.85 MPa (adjustable)
Maximum Inlet Pressure 1.0 MPa
Flow Coefficient (Kv) 4 - 160 m³/h (varies by size)
Seat Leakage Class ANSI Class IV
Ambient Temperature Limit -30°C to +80°C

This pressure reducing valve delivers significant operational benefits:

  • Energy savings through optimized system pressure reduces pump/compressor workload

  • Extended equipment lifespan by preventing pressure surges in downstream components

  • Reduced water hammer risk through gradual pressure adjustment mechanism

  • Simplified installation with horizontal/vertical mounting capability

Backed by Shanghai Sote Valve's 15-year manufacturing expertise and comprehensive quality control system, this pressure reducing valve undergoes rigorous performance testing before shipment. Our technical support team provides application-specific sizing guidance and installation recommendations. Custom configurations including special materials, pressure ranges, and connection types are available upon request to meet unique operational requirements.

FAQ Section

Q1: What maintenance does this valve require?
A: The modular design allows easy diaphragm replacement without removing the valve body. Annual inspection of the pilot filter is recommended.

Q2: Can it handle saturated steam applications?
A: Yes, all standard models are suitable for saturated steam service up to 150°C when installed with proper orientation.

Q3: Is the outlet pressure adjustable during operation?
A: The pressure setting can be adjusted via the external pilot knob while the system is running.

Q4: What is the response time for pressure regulation?
A: Typical stabilization occurs within 2-5 seconds after upstream pressure changes under normal flow conditions.

Q5: Are special tools required for installation?
A: Standard piping tools are sufficient. Ensure upstream strainer installation as specified in the manual.

Q6: Can it be used for aggressive media?
A: Optional stainless steel bodies and PTFE diaphragms are available for corrosive applications.

Q7: What is the minimum pressure differential required?
A: Stable operation requires at least 0.05 MPa differential between inlet and outlet pressures.

Q8: Do you provide dimensional drawings?
A: Complete CAD drawings and installation dimensions are available for download on our product page.

Product Tags: Diaphragm Pressure Reducing Valve , Pilot Operated Pressure Regulator , Constant Outlet Pressure Valve

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
1Yr
Verified Business License
Product Certifications
ISO9001, ISO9004, OHSAS18001, Others
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market
Location
Shanghai, China