ECG Waveform Simulator

ECG Waveform Simulator photo-1
Negotiable MOQ: 1 Combo (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Business Type:
Trading Company
Year Established:
2023
Factory Size:
Below 1,000 square meters
Payment & Shipping
Payment Methods:
Port of Shipment:
SHANGHAI
Delivery Detail:
20 days

ECG Signal Generator

SKX-2000C+/D+/G+/SUP+

Function Features

l Using 10 multipurpose ECG connectors, it can easily and quickly connect the lead line of ECG products such as monitor and ECG machine.

l 12 leads synchronous ECG signal output, output different 12-lead ECG waveform.

l Built-in 18650 large capacity lithium battery, power management module, in the process of use to ensure stable power supply, low interference output; Optional standard micro usb universal interface power charger.

l Using menu operation, parameter change is simple, convenient and fast,

 convenient for users to set.

l Using OLED display, display menu content.

l Simple button operation, menu management, easy to use.

l Built-in waveform setting instructions in both Chinese and English,

easy to understand the waveform setting and parameter selection.

 

No.

Type of waveform

intro

1

Ecg waveform

Two different ECG waveforms that mimic the human body

2

Sharp Angle Waveforms

Waveform used to detect heart rate accuracy and heart rate range

3

Calibrating waveforms

A standard amplitude signal used to calibrate the amplitude of ECG equipment

4

Irregular heart rate

Four irregular heart rate waveforms in the MIT database for measuring the heart rate performance of ECG devices

5

Square Waves

Used to test the curve scanning speed and time constant performance of ECG equipment

6

Sine wave

Used to detect amplitude-frequency characteristics and other related properties

7

Respiratory waveform

Detection of respiratory parameter performance in ECG devices with respiratory function

8

Triangular Waveforms

Triangular waveforms with varying bottom widths are used to detect R-wave recognition rates for different widths

9

Synchronous pacing

Detection of pacing signal suppression and recognition by ECG equipment

10

QRST waveform

It is used to simulate the QRST waveform of the human body of the instrument and detect the related performance of T wave and R wave

11

Pacemaker pulse

Detect the suppression of pacing signals by the ECG device

12

Stacking Waveforms

Interference suppression of ECG signals that superimpose 35Hz, 50Hz, 60Hz sine wave signals

13

Abnormal waveforms

Many types of abnormal waveforms

 

Types of abnormal Waveforms


l Rough atrial fibrillation

l Fine atrial fibrillation

l Atrial flutter

l Sinus arrhythmia

l Heartbeat loss

l Atrial tachycardia

l Nodal rhythm

l Supraventricular tachycardia

l Preatrial systole

l Prenodal systole

l Preventricular contraction 1

l Preventricular systole 1

l Preventricular systole 3

l Preventricular systole 4

l Preventricular systole 5

l Preventricular contraction 6

l Multifocal precontraction

l 5 Ventricular precontraction

l 11 Preventricular systole

l 24 Preventricular systole

l Frequent multi-focal contraction

l The rate of ventricular prothesis

l Triplet of ventricular premature

l Paired ventricular contractions

l 5 ventricular contractions

l 11 ventricular contractions

l Ventricular tachycardia

l Coarse ventricular fibrillation

l Fine ventricular fibrillation

l Stopbo

l First degree heart block

l Second degree heart block

l Third degree heart block

l Right bundle branch block

l Left bundle branch block

l Respiratory arrhythmia

l Sinus bradycardia


 

Model Configuration Sheet

Model number (Model)

SKX-2000C+

SKX-2000D+

SKX-2000G+

SKX-2000SUP+

Waveform Configuration (Configuration)

1-3

1-7

1-12

1-13

Optional invasive voltage IBP (electrical signal)

Basic waveform type parameter list description

Waveform Types

Items

Parameters

Ecg waveform

Ordinary ECG

Heart rate range: 20 bpm-300 bpm

Sinus ECG

Heart rate range: 20 bpm-100 bpm


Amplitude

Amplitude range: 0.5 mV, 1 mV, 2 mV 3 kinds of fixed amplitude


Sharp corner waveform

Heart Rate

Heart rate range: 20 bpm-400 bpm

Amplitude

Amplitude range: 0.10mV-5.00mV


Direction

Up, Down


Calibrating waveform

Heart Rate

Heart rate range: 30 bpm-120 bpm

Amplitude

Amplitude range: 0.10mV-5.00mV


breadth

Width range: 40 ms-200 ms  


Irregular heart rate

Bigeminy rate

Heart rate value: 80 bpm or 40 bpm

Slow double rate

Heart rate value: 60 bpm or 30 bpm


Fast double rate

Heart rate value: 120 bpm


Bidirectional contraction

Heart rate value: 90 bpm or 45 bpm


Square Wave

Frequency

Frequency range: 0.1Hz-5.0Hz   

Amplitude

Amplitude range: 0.10 mv-4.00 mV


Sinusoidal wave

Frequency

Frequency range: 0 Hz-150 Hz, including 0.67Hz

Amplitude

Amplitude range: 0.10mV-5.00mV


Bias voltage

Voltage range: 10 mV-500 mV


Respiratory waveform

Respiratory rate

Heart rate range: 5 bpm-120 bpm

Breathing range

Amplitude range: 0.3R-3.0R        


Waveform period

Period range: 20 bpm-120 bpm


Choking time

Time range: 0 S - 120 S         


Triangular waveform

Heart Rate

Heart rate range: 30 bpm-200 bpm

R Width

Width range: 10 ms - 200 ms


R amplitude

Amplitude range: 0.10 mv-5.00 mV  


Direction

Up, Down


Synchronous pacing

Heart Rate

Heart rate range: 30 bpm-200 bpm  

P Width

Width range: 0.1ms - 2.0ms  


P amplitude

Amplitude range: 0.10 mv-4.00 mV   


P direction

Up, down


QRST waveform

T-Amplitude

Amplitude range: 0.00 mv-1.20 mV   

R-Amplitude

Amplitude range: 0.10 mv-4.00 mV


R Heart Rate

Heart rate range: 10 bpm-200 bpm


R Width

Width range: 10 ms - 200 ms   


ST

Amplitude range: -0.90 mV -0.90 mV


Pacing pulse

P heart rate

Heart rate range: 20 bpm - 300 bpm

P width

Width range: 0.1ms - 2.0ms  


P amplitude

Amplitude range: 0.10 mv-5.00 mV   


P direction

Up, down


Superimposed waveform

Heart Rate

Heart rate value: 80 bpm fixed value

Frequency

Frequency range: 30 Hz - 60 Hz    


Amplitude

Amplitude range: 0.05mV-1.00mV    


Note: The amplitude error of SKX-2000+ series products is less than 2%, the frequency error is less than 1%

图片3.png

Product Tags: ECG Signal Simulator , ECG Signal Generator , Electrocardiogram Signal Simulator

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Trading Company
Year Established
2023
Factory Size
Below 1,000 square meters
Annual Export Value
US$1.5 Million - US$2.5 Million

Recommended Categories

Explore top categories and find suppliers for your specific needs